scholarly journals LI-Care: A LabVIEW and IoT Based eHealth Monitoring System

Electronics ◽  
2021 ◽  
Vol 10 (24) ◽  
pp. 3137
Author(s):  
Kunjabihari Swain ◽  
Murthy Cherukuri ◽  
Sunil Kumar Mishra ◽  
Bhargav Appasani ◽  
Suprava Patnaik ◽  
...  

This paper presents a Laboratory Virtual Instrument Engineering Workbench (LabVIEW) and Internet of Things (IoT)-based eHealth monitoring system called LI-Care to facilitate the diagnosis of the health condition cost-effectively. The system measures the heart rate, body temperature, blood pressure, oxygen level, and breathing rate, and provides an electrocardiogram (ECG). The required sensors are integrated on a web-based application that keeps track of the essential parameters and gives an alarm indication if one or more physiological parameters go beyond the safe level. It also employs a webcam to obtain the patient view at any time. LabVIEW enables the effortless interfacing of various biomedical sensors with the computer and provides high-speed data acquisition and interactive visualizations. It also provides a web publishing tool to access the interactive window remotely through a web browser. The web-based application is accessible to doctors who are experts in that particular field. They can obtain the real-time reading and directly perform a diagnosis. The parameters measured by the proposed system were validated using the traditional measurement systems, and the Root Mean Square (RMS) errors were obtained for the various parameters. The maximum RMS error as a percentage was 0.159%, which was found in the temperature measurement, and its power consumption is 1 Watt/h. The other RMS errors were 0.05% in measurement of systolic pressure, 0.029% in measurement of diastolic pressure, 0.059% in measurement of breathing rate, 0.002% in measurement of heart rate, 0.076% in measurement of oxygen level, and 0.015% in measurement of ECG. The low RMS errors and ease of deployment make it an attractive alternative for traditional monitoring systems. The proposed system has potential applications in hospitals, nursing homes, remote monitoring of the elderly, non-contact monitoring, etc.

1960 ◽  
Vol 199 (5) ◽  
pp. 797-799 ◽  
Author(s):  
S. Deavers ◽  
E. L. Smith ◽  
R. A. Huggins

Mean control data on a series of 100 dogs are presented. Cell volume, measured with Cr51-tagged red cells and plasma volume determined simultaneously by T-1824 dye was 33.5 ± 0.74 cc/kg and 50.2 ± 1.11 cc/kg, respectively. The venous hematocrit was 45.2% and the circulatory/venous hematocrit ratio was 0.89 ± 0.01 for the group. The plasma protein concentration of these animals was 6.25 ± 0.07 gm/100 cc. No difference in blood volume per unit of body weight was found between large (12.6 kg) and small (5.8 kg) dogs. The femoral mean systolic pressure was 139.0 ± 2.53 mm Hg, the diastolic pressure 65.6 ± 1.46 mm Hg and the heart rate 85.9 ± 2.86/min.


1981 ◽  
Vol 61 (s7) ◽  
pp. 373s-375s ◽  
Author(s):  
P. D. Arkwright ◽  
L. J. Beilin ◽  
I. Rouse ◽  
B. K. Armstrong ◽  
R. Vandongen

1. The association between alcohol consumption and blood pressure was studied in 491 Government employees. The men, aged 21–45 years, volunteered to complete a health questionnaire and submitted to standardized measurements of blood pressure, heart rate and body size. 2. Average weekly alcohol consumption correlated with systolic pressure (r = 0.18, P < 0.001) but not with diastolic pressure. Systolic pressure increased progressively with increasing alcohol consumption with no obvious threshold effect. The effect of alcohol was independent of age, obesity (Quetelet's index) or cigarette smoking. 3. Results indicate that alcohol ranks close to obesity as a preventable cause of essential hypertension in the community.


J ◽  
2019 ◽  
Vol 2 (2) ◽  
pp. 206-225 ◽  
Author(s):  
Nadeesha Gunaratne ◽  
Claudia Viejo ◽  
Thejani Gunaratne ◽  
Damir Torrico ◽  
Hollis Ashman ◽  
...  

Study of emotions has gained interest in the field of sensory and consumer research. Accurate information can be obtained by studying physiological behavior along with self-reported-responses. The aim was to identify physiological and self-reported-responses towards visual stimuli and predict self-reported-responses using biometrics. Panelists (N = 63) were exposed to 12 images (ten from Geneva Affective PicturE Database (GAPED), two based on common fears) and a questionnaire (Face scale and EsSense). Emotions from facial expressions (FaceReaderTM), heart rate (HR), systolic pressure (SP), diastolic pressure (DP), and skin temperature (ST) were analyzed. Multiple regression analysis was used to predict self-reported-responses based on biometrics. Results showed that physiological along with self-reported responses were able to separate images based on cluster analysis as positive, neutral, or negative according to GAPED classification. Emotional terms with high or low valence were predicted by a general linear regression model using biometrics, while calm, which is in the center of emotion dimensional model, was not predicted. After separating images, positive and neutral categories could predict all emotional terms, while negative predicted Happy, Sad, and Scared. Heart Rate predicted emotions in positive (R2 = 0.52 for Scared) and neutral (R2 = 0.55 for Sad) categories while ST in positive images (R2 = 0.55 for Sad, R2 = 0.45 for Calm).


1999 ◽  
Vol 90 (3) ◽  
pp. 681-692 ◽  
Author(s):  
Joel L. Parlow ◽  
Gerard Begou ◽  
Pierre Sagnard ◽  
Jean Marie Cottet-Emard ◽  
Jean Claude Levron ◽  
...  

Background Patients with essential hypertension show altered baroreflex control of heart rate, and during the perioperative period they demonstrate increased circulatory instability. Clonidine has been shown to reduce perioperative circulatory instability. This study documents changes in measures of heart rate control after surgery in patients with essential hypertension and determines the effects of clonidine on postoperative heart rate control in these patients. Methods Using a randomized double-blind placebo-controlled design, 20 patients with essential hypertension (systolic pressure >160 mm Hg or diastolic pressure >95 mm Hg for > or =1 yr) were assigned to receive clonidine (or placebo), 6 microg/kg orally 120 min before anesthesia and 3 microg/kg intravenously over 60 min before the end of surgery. The spontaneous baroreflex ("sequence") technique and analysis of heart rate variability were used to quantify control of heart rate at baseline, before induction of anesthesia, and 1 and 3 h postoperatively. Results Baroreflex slope and heart rate variability were reduced postoperatively in patients given placebo but not those given clonidine. Clonidine resulted in greater postoperative baroreflex slope and power at all frequency ranges compared with placebo (4.9+/-2.9 vs. 2.2+/-2.1 ms/mm Hg for baroreflex slope, 354+/-685 vs. 30+/-37 ms2/Hz for high frequency variability). Clonidine also resulted in lower concentrations of catecholamine, decreased mean heart rate and blood pressure, and decreased perioperative tachycardia and hypertension. Conclusions Patients with hypertension exhibit reduced heart rate control during the recovery period after elective surgery. Clonidine prevents this reduction in heart rate control. This may represent a basis for the improved circulatory stability seen with perioperative administration of clonidine.


1983 ◽  
Vol 65 (2) ◽  
pp. 143-147 ◽  
Author(s):  
A. D. Struthers ◽  
J. L. Reid ◽  
R. Whitesmith ◽  
J. C. Rodger

1. Adrenaline was infused intravenously in nine normal volunteers to plasma concentrations similar to those found after myocardial infarction. This study was undertaken on three occasions after 5 days' treatment with placebo or the β-adrenoceptor antagonists, atenolol or timolol. 2. Adrenaline increased the systolic pressure by 11 mmHg, decreased the diastolic pressure by 14 mmHg, and increased the heart rate by 7 beats/min. These changes were prevented by atenolol. However, after timolol the diastolic pressure rose (+19 mmHg) and heart rate fell (− 8 beats/min). 3. Adrenaline caused the corrected QT interval (QTc) to lengthen (0.36 ± 0.02 s to 0.41 ± 0.06 s). No significant changes were found in the QTc when subjects were pretreated with atenolol or timolol. 4. The serum potassium fell from 4.06 to 3.22 mmol/l after adrenaline. Serum potassium fell to a lesser extent to 3.67 mmol/l after atenolol and actually increased to 4.25 mmol/l after timolol. Adrenaline-mediated hypokalaemia appears to result from the stimulation of a β2-adrenoceptor linked to membrane Na+/K+-ATPase causing potassium influx.


1990 ◽  
Vol 2 (1) ◽  
pp. 37-45 ◽  
Author(s):  
Karen L. Nau ◽  
Victor L. Katch ◽  
Robert H. Beekman ◽  
Macdonald Dick

Intraarterial blood pressure (BP) response to bench press weight lifting (WL) was evaluated in 11 children. Aortic systolic and diastolic pressures and heart rate (HR) were measured during WL. Baseline systolic and diastolic pressures were 120 and 81 mmHg, and HR was 86 bpm. Subjects lifted to voluntary fatigue weights equaling 60, 75, 90, and 100% of their predetermined one-repetition maximum (1RM). For each weight lifting condition, BP and HR increased as more repetitions were completed. Peak systolic pressure was 168, 177, 166, and 162 mmHg, peak diastolic pressure was 125, 139, 133, and 130 mmHg, and peak heart rate was 142, 148, 142, and 139 bpm at 60, 75, 90, and 100% 1RM, respectively. Peak BP and HR were greater during WL than rest but did not differ between conditions. The relative BP response to WL in children was similar to adult values. For all conditions, pressures increased as more repetitions were completed. It was concluded that peak pressures occur at voluntary fatigue, independent of the combination of resistance and repetitions used to achieve fatigue.


This research work aims to create awareness and monitor the breath rate of a neonate using the air flow sensors and to reduce the number of infants’ death. It is designed based on the Arduino which is open-source electronics platform for hardware and software use. This prototype is developed for reliable and efficient baby monitoring system and play as infant care and monitoring system.A cardio respiratory system is used to monitor the infant’s heart rate, rhythm, breathing rate and other relevant and useful medical information using Electro Cardio Graph (ECG) and other IoT (Internet of Things) devices.This research work proved that the respiration monitoring system for infants can be implemented at low cost and also can prevent the respiration failure deaths.


2022 ◽  
Vol 28 (1) ◽  
pp. 27-30
Author(s):  
Keyin Liu

ABSTRACT Introduction: Basketball can enhance the physical fitness of young people, promote the growth and development of their bodies, and improve health and athletic ability. Objective: To explore the characteristics of basketball players’ cardiac response to increasing load training. Methods: By analyzing 12 juvenile male amateur basketball training athletes, when performing incremental load exercises on the treadmill, using a 12-lead electrocardiograph to record the electrocardiogram, HR, and blood pressure responses for each level of exercise. Results: The mean heart rate of the basketball players before movement was 82.45± 11.44 bpm, slightly higher than the heart rate at rest. Depending on the exercise load, the blood pressure should increase by 5 to 12 mmHg. Under different load training conditions, each level of blood pressure in the Bruce treadmill test procedure should increase 12.5 ~ 44mmHg. The basketball player’s systolic pressure increased by 2.25 ~ 15.7mmHg, diastolic pressure increased by 0.43 to 11.37 mmHg. Conclusions: In basketball players, the psychological stress is less than that of the average person performing the same exercise. The strong ability to adapt to exercise under incremental load training, the contractility of the ventricular muscles and the development of the heart are good. Level of evidence II; Therapeutic studies - investigation of treatment results.


Author(s):  
Prathima Padavarahalli Thammanna ◽  
Kavya Marasandra Seetharam ◽  
Tejesh Channasandra Anandaswamy ◽  
Prapti Rath ◽  
Geetha Chamanhalli Rajappa ◽  
...  

Background: Videolaryngoscopes are now being advocated as the universal device for airway management due to their ability to provide an improved glottic visualisation. Due to their ability to see around the corners, they obviate the need to align the airway axes and thus may lead to less airway stimulation. This may result in less haemodynamic response during laryngoscopy and intubation. The present study was designed to compare the haemodynamic response to intubation with King Vision and C-MAC videolaryngoscopes. Methods: After obtaining informed consent, adults with unanticipated difficult intubation, scheduled to undergo surgery under general anaesthesia were randomised to be intubated with either King Vision (Group K) or C-MAC (Group C) videolaryngoscope. Following a standardised general anaesthesia induction protocol all subjects were intubated with the allocated videolaryngoscope and haemodynamic parameters (heart rate, systolic pressure, diastolic pressure and mean arterial pressure) were recorded at specific time points. Statistical analysis was done using the SPSS Software (version 18.0). Results: The changes in the heart rate, systolic pressure, diastolic pressure and mean arterial pressure following laryngoscopy and intubation with the allocated videolaryngoscope were statistically similar between the two groups at all time points. Conclusion: Haemodynamic responses to laryngoscopy and intubation with King Vision and C-MAC videolaryngoscopes were similar.


Sign in / Sign up

Export Citation Format

Share Document