scholarly journals Energy Saving of Composite Agglomeration Process (CAP) by Optimized Distribution of Pelletized Feed

Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2382 ◽  
Author(s):  
Guanghui Li ◽  
Chen Liu ◽  
Zhengwei Yu ◽  
Mingjun Rao ◽  
Qiang Zhong ◽  
...  

The composite agglomeration process (CAP) aims at sintering a pelletized feed and a matrix feed together to produce a high-quality burden for a blast furnace. The pelletized feed is balled from fine iron concentrate or refractory iron-bearing resources, while the matrix feed is granulated from iron ore fines, fuels, fluxes and so on. Through mathematical calculation, heat accumulation regularity and heat-homogenizing of the sinter bed are acquired in CAP when pelletized feed is uniformly distributed. Then they are studied in the composite agglomeration process with optimized pelletized feed distribution, which is a novel and perfect sinter bed structure. Results show that large heat input gaps exist in the sinter bed under condition of even sinter mixture distribution, and it is very difficult to realize bed heat-homogenization by directly varying the solid fuel dosage among each layer. An optimized pelletized feed distribution realizes more heat in the upper layer together with heat-homogenization of the middle-lower layer when the proportions of pellets increase first in the middle-upper layer and then decrease in the middle-lower layer of the sinter bed. Under these circumstances, the sinter bed has much better available accumulation ratios with a maximum value of 78.29%, and possesses a greater total heat input of 6754.27 MJ when the coke breeze remains at the original dosage. To make full use of the available heat accumulation and adjust the pellet distribution, a good energy saving effect is obtained because the coke breeze mass declines by 13.91 kg/t-sinter. The current gross heat inputs of each unit are reduced remarkably, leading to a total heat input decrease of 25.95%. In pot tests of CAP, the differences of thermal parameters in whole bed are obviously reduced with the optimized pelletized feed distribution, which contributes to sinter homogeneity and energy savings.

Fluids ◽  
2021 ◽  
Vol 6 (8) ◽  
pp. 275
Author(s):  
Ahmed J. Hamad

One essential utilization of phase change materials as energy storage materials is energy saving and temperature control in air conditioning and indirect solar air drying systems. This study presents an experimental investigation evaluating the characteristics and energy savings of multiple phase change materials subjected to internal flow in an air heating system during charging and discharging cycles. The experimental tests were conducted using a test rig consisting of two main parts, an air supply duct and a room model equipped with phase change materials (PCMs) placed in rectangular aluminum panels. Analysis of the results was based on three test cases: PCM1 (Paraffin wax) placed in the air duct was used alone in the first case; PCM2 (RT–42) placed in the room model was used alone in the second case; and in the third case, the two PCMs (PCM1 and PCM2) were used at the same time. The results revealed a significant improvement in the energy savings and room model temperature control for the air heating system incorporated with multiple PCMs compared with that of a single PCM. Complete melting during the charging cycle occurred at temperatures in the range of 57–60 °C for PCM1 and 38–43 °C for PCM2, respectively, thereby validating the reported PCMs’ melting–solidification results. Multiple PCMs maintained the room air temperature at the desired range of 35–45.2 °C in the air heating applications by minimizing the air temperature fluctuations. The augmentation in discharging time and improvement in the room model temperature using multiple PCMs were about 28.4% higher than those without the use of PCMs. The total energy saving using two PCMs was higher by about 29.5% and 46.7% compared with the use of PCM1 and PCM2, respectively. It can be concluded that multiple PCMs have revealed higher energy savings and thermal stability for the air heating system considered in the current study.


2021 ◽  
pp. 1420326X2199241
Author(s):  
Hanlin Li ◽  
Dan Wu ◽  
Yanping Yuan ◽  
Lijun Zuo

In the past 30 years, tubular daylight guide systems (TDGSs) have become one of the most popular ways to transport outdoor natural light into the inner space in building design. However, tubular daylight guide systems are not widely used because of the lack of methods to evaluate methods on the suitability of the TDGSs. This study therefore summarizes the daylight performance metrics of TDGSs and presents the estimation methods in terms of field measurements, simulation and empirical formulae. This study focuses on the daylight performance and potential energy savings of TDGSs. Moreover, this study will be helpful for building designers to build healthy, comfortable and energy-saving indoor environment.


2001 ◽  
Vol 8 (4) ◽  
pp. 234-238
Author(s):  
De-qing Zhu ◽  
Guan-zhou Qiu ◽  
Tao Jiang ◽  
Bao-jun Zhu

2012 ◽  
Vol 512-515 ◽  
pp. 2863-2866
Author(s):  
Hong Bing Chen ◽  
Ping Wei

Aiming at the current unreasonable heat charge policy, this paper describes the necessity of consumption-based heat bill system, introduces the basic ideas and problems of household heat metering and central control on total heat supply, and analyzes the relationship of household heat metering and central control. The study shows these two aspects should be well coordinated wit[h each other for better energy savings.


2022 ◽  
Vol 21 (1) ◽  
pp. 1-24
Author(s):  
Sheel Sindhu Manohar ◽  
Sparsh Mittal ◽  
Hemangee K. Kapoor

In the deep sub-micron region, “spin-transfer torque RAM” (STT-RAM ) suffers from “read-disturbance error” (RDE) , whereby a read operation disturbs the stored data. Mitigation of RDE requires restore operations, which imposes latency and energy penalties. Hence, RDE presents a crucial threat to the scaling of STT-RAM. In this paper, we offer three techniques to reduce the restore overhead. First, we avoid the restore operations for those reads, where the block will get updated at a higher level cache in the near future. Second, we identify read-intensive blocks using a lightweight mechanism and then migrate these blocks to a small SRAM buffer. On a future read to these blocks, the restore operation is avoided. Third, for data blocks having zero value, a write operation is avoided, and only a flag is set. Based on this flag, both read and restore operations to this block are avoided. We combine these three techniques to design our final policy, named CORIDOR. Compared to a baseline policy, which performs restore operation after each read, CORIDOR achieves a 31.6% reduction in total energy and brings the relative CPI (cycle-per-instruction) to 0.64×. By contrast, an ideal RDE-free STT-RAM saves 42.7% energy and brings the relative CPI to 0.62×. Thus, our CORIDOR policy achieves nearly the same performance as an ideal RDE-free STT-RAM cache. Also, it reaches three-fourths of the energy-saving achieved by the ideal RDE-free cache. We also compare CORIDOR with four previous techniques and show that CORIDOR provides higher restore energy savings than these techniques.


Author(s):  
Branislav Ftorek ◽  
Milan Saga ◽  
Pavol Orsansky ◽  
Jan Vittek ◽  
Peter Butko

Purpose The main purpose of this paper is to evaluate the two energy saving position control strategies for AC drives valid for a wide range of boundary conditions including an analysis of their energy expenses. Design/methodology/approach For energy demands analysis, the optimal energy control based on mechanical and electrical losses minimization is compared with the near-optimal one based on symmetrical trapezoidal speed profile. Both control strategies respect prescribed maneuver time and define acceleration profile for preplanned rest-to-rest maneuver. Findings Presented simulations confirm lower total energy expenditures of energy optimal control if compared with near-optimal one, but the differences are only small due to the fact that two energy saving strategies are compared. Research limitations/implications Developed overall control system consisting of energy saving profile generator, pre-compensator and position control system respecting principles of field-oriented control is capable to track precomputed state variables precisely. Practical implications Energy demands of both control strategies are verified and compared to simulations and preliminary experiments. The possibilities of energy savings were confirmed for both control strategies. Originality/value Experimental verification of designed control structure is sufficiently promising and confirmed assumed energy savings.


Author(s):  
Yigit Fidansoy ◽  
Sohejl Wanjani ◽  
Sebastian Schmidt

Due to the increasing scarcity of fossil fuels and the climate change, the importance of energy efficiency is increasing. This importance is major especially in areas where the energy consumption is high. Rail transport depicts such an area. The highest proportion of energy consumed in the railway is the so called traction energy. This energy is required for the train run. In the timetable, allowances leave a margin for the driving style of train run. By the selective use of strategies that change the driving style, it is possible to exploit these allowances and reduce the traction energy consumption. The first objective of this study deals with the development of algorithms for energy-saving driving style. First, the necessary input variables of the algorithms based on the literature research and the formulas of train dynamics were determined. Then the algorithms were developed to create different energy-saving driving styles, resulting choose the best result which should be shown as a driving recommendation. The developed algorithms were used in an application example in order to calculate the potential of energy-savings. The example should represent the influence of the input variables for a comparison of different situations. At last the acceptance of the determined driving strategies in practice was investigated. By implementing the design thinking method it was identified that driver advisory systems and training programs are necessary to facilitate energy-saving driving in practice.


2021 ◽  
Author(s):  
◽  
Georgia Alexander

<p>For decades, studies have been suggesting the idea of occupancy sensors in intermittent use spaces for energy savings. This work investigates the potential energy savings of occupancy sensors in hallways, stairwells, seminar rooms and lavatories of an education building. Lighting is one of the largest consumers of energy in the building industry and these space types are often fully illuminated for long periods of vacancy. Lighting is for the user, not the building. Discussions centre around light use habits, energy saving behaviours and sensor technology such as time delay and daylight sensors. The experiment uses wireless light sensors and PIR sensors to measure light energy use and occupant use of 20 intermittent use spaces. A user survey was planned to run alongside the experiment to investigate user perceptions of changes in lighting but was discontinued due to unresolved software issues. Results of the experiment encouraged the use of occupancy sensors in intermittent use spaces. Lavatories attained highest energy saving potential 54%, seminar rooms highest annual cost savings per fitting $15.47 and highest annual energy savings 482kWh and hallways calculated the quickest payback of 8.6 years. Hallways, stairwells, seminar rooms and lavatories all offer potential for energy savings, supporting the theoretical ideas and success of occupancy sensors in intermittent use spaces.</p>


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


Author(s):  
N.Sujith Prasanna ◽  
Dr.J.Nagesh Kumar

Energy cost is significant in many of the manufacturing activities. The efficiency of energy use is quiet low as there are substantial visible and hidden losses. Visible losses can be easily identified and corrective action can be taken. However hidden and indirect losses form a sizeable portion of the losses. Identifying these losses is not easy and requires an integrated approach which includes thorough study of process, operations and their interactions with energy use. Industries across sectors have implemented lean management principles which target various wastes occurring in the plant. This paper discusses case studies which highlight the exploitation of lean tools as a means for unearthing hidden energy saving potential that often go unnoticed. In addition to the energy savings which results in improved profits and competitiveness, the approach also aids the industry to pursue a path of sustainable manufacturing.


Sign in / Sign up

Export Citation Format

Share Document