scholarly journals Energy Consumption in a Distributional Warehouse: A Practical Case Study for Different Warehouse Technologies

Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2709
Author(s):  
Konrad Lewczuk ◽  
Michał Kłodawski ◽  
Paweł Gepner

Energy consumption by distribution warehouses has become an essential component of green warehousing and research on reducing the carbon footprint of supply chains. Energy consumption in warehousing is a complex and multilayered problem, which is generally considered in the literature in relation to its detailed components, not as part of comparative studies. In this article, the authors consider six cross-sectional variants of warehouse technology, from manual to fully automatic, and analyze the energy consumption of a warehouse in various configurations. A methodology for estimating storage space and determining energy consumption is proposed. The energy balance of the warehouse variants includes energy for material handling equipment operation, energy consumption for building maintenance (heating, cooling, lighting, etc.), and energy generated by the photovoltaic system on the roof. Then, the operational costs of the variants are estimated and, on their basis, an automation index is determined. The index allows for a comparative analysis of energy consumption and the mechanization and automation of a warehouse. It is shown that a significant part of the energy is spent on maintaining a warehouse building, especially in the case of facilities with a low degree of automation.

Author(s):  
M. A. Pardo ◽  
Juan Manzano ◽  
Diego García

Due to the fact that irrigation networks are water and energy-hungry and that both resources are scarce, many strategies have been developed to reduce this consumption. Otherwise, solar energy sources have become a green alternative with lower energy costs and, as a consequence, lower environmental impacts. In this work, it is proposed a new methodology to select the scheduled program for irrigation which minimizes the number of photovoltaic solar panels to be installed and which better fits energy consumption (calculated for discrete potential combinations; using a programming software to assist) to available energy obtained by panels without any power conditioning unit. So, the irrigation hours available to satisfy the water demands are limited by sunlight, the schedule type of irrigation has to be rigid (rotation predetermined) and the pressure at any node has to be above the minimum pressure required by standards. A real case study has been performed.


2020 ◽  
Vol 186 ◽  
pp. 01004
Author(s):  
Pathomthat Chiradeja ◽  
Atthapol Ngaopitakkul

Renewable energy especially solar energy has become a significant part in electrical power generation with its advantage in the environmentally friendly and current trend of decrease in installation cost. The photovoltaic (PV) system on a rooftop is one of the power generating system based on renewable energy that can fit building to utilize space efficiently. This paper is analyzing the feasibility of installing a solar PV rooftop on the building using a case study building located in Bangkok, Thailand. The performance will be evaluated in term of both energy and economic perspective. The comparison with Thailand building energy code also been done to show that overall energy consumption with PV system complies with the law. The result has shown that with rooftop photovoltaic system installation, annual energy consumption in the building can be reduced significantly and it can achieve feasibility in term of economic perspective.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 100
Author(s):  
Horia Andrei ◽  
Cristian Andrei Badea ◽  
Paul Andrei ◽  
Filippo Spertino

Wastewater treatment plants and power generation constitute inseparable parts of present society. So the growth of wastewater treatment plants is accompanied by an increase in the energy consumption, and a sustainable development implies the use of renewable energy sources on a large scale in the power generation. A case study of the synergy between wastewater treatment plants and photovoltaic systems, aiming to improve the energetic, environmental and economic impacts, is presented. Based on data acquisition, the energy consumption analysis of wastewater treatment plant reveals that the highest demand is during April, and the lowest is during November. The placement of photovoltaic modules is designed to maximize the use of free space on the technological area of wastewater treatment plant in order to obtain a power output as high as possible. The peak consumption of wastewater treatment plant occurs in April, however the peak production of the photovoltaic is in July, so electrochemical batteries can partly compensate for this mismatch. The impact of the photovoltaic system connectivity on power grid is assessed by means of the matching-index method and the storage battery significantly improves this parameter. Carbon credit and energy payback time are used to assess the environmental impact. The results prove that the photovoltaic system mitigates 12,118 tons of carbon and, respectively, the embedded energy is compensated by production in 8 ½ years. The economic impact of the photovoltaic system is analyzed by the levelized cost of energy, and the results show that the price of energy from the photovoltaic source is below the current market price of energy.


Electronics ◽  
2021 ◽  
Vol 10 (22) ◽  
pp. 2829
Author(s):  
Samah Temim ◽  
Farid Bensebaa ◽  
Larbi Talbi

In this paper, a modeling framework to quantify the reduction of potential greenhouse gas (GHG) emissions when using solar-powered Wi-Fi as an internet access point is developed and tested. This framework includes newly developed MATLAB code and the use of the ATOLL tool for energy consumption and network optimization, respectively. A practical case study is described with scenarios enabling different signal coverage on a university campus. These scenarios are based on technical requirements, including number of access points, budget link, and access duration. Four hundred tons of GHG can be reduced each year if solar Wi-Fi is deployed in solar campuses, which represents 5.5 × 10−5 percent of the total GHG produced by the telecommunications sector. A direct relationship between the number of access points and coverage signal quality on the one hand and energy consumption on the other hand is established. We use this case study to forecast the potential GHG mitigation if a wider deployment of the community Wi-Fi is achieved. This methodology could also be used to estimate GHG reductions when other wireless technologies are deployed.


Author(s):  
Junaidah Jailani ◽  
◽  
Norsyalifa Mohamad ◽  
Muhammad Amirul Omar ◽  
Hauashdh Ali ◽  
...  

According to the National Energy Balance report released by the Energy Commission of Malaysia in 2016, the residential sector uses 21.6% of the total energy in Malaysia. Residents waste energy through inefficient energy consumption and a lack of awareness. Building occupants are considered the main factor that influences energy consumption in buildings, and to change energy consumption on an overall scale, it is crucial to change individual behaviour. Therefore, this study focused on analysing the energy consumption pattern and the behaviour of consumers towards energy consumption in their homes in the residential area of Batu Pahat, Johor. A self-administrated questionnaire approach was employed in this study. The findings of this study showed that the excessive use of air conditioners was a significant factor in the increasing electricity bills of homeowners as well as the inefficient use of electrical appliances. Also, this study determined the effect of awareness on consumer behaviour. This study recommends ways to help minimise energy consumption in the residential area.


Author(s):  
Yongkai Zhou ◽  
Jie Zhu ◽  
Han Wei Teo ◽  
ACT Quah ◽  
Lei Zhu ◽  
...  

Abstract In this paper, two failure analysis case studies are presented to demonstrate the importance of sample preparation procedures to successful failure analyses. Case study 1 establishes that Palladium (Pd) cannot be used as pre-FIB coating for SiO2 thickness measurement due to the spontaneously Pd silicide formation at the SiO2/Si interface. Platinum (Pt) is thus recommended, in spite of the Pt/SiO2 interface roughness, as the pre-FIB coating in this application. In the second case study, the dual-directional TEM inspection method is applied to characterize the profile of the “invisible” tungsten residue defect. The tungsten residue appears invisible in the planeview specimen due to the low mass-thickness contrast. It is then revealed in the cross-sectional TEM inspection.


Sign in / Sign up

Export Citation Format

Share Document