scholarly journals Comparative Studies of Hyaluronic Acid Concentration in Normal and Osteoarthritic Equine Joints

Fluids ◽  
2019 ◽  
Vol 4 (4) ◽  
pp. 193
Author(s):  
Matisioudis ◽  
Rizos ◽  
Tyrnenopoulou ◽  
Papazoglou ◽  
Diakakis ◽  
...  

Osteoarthritis (OA) is the most common major disabling disease in humans and horses. Hyaluronic acid (HA), naturally abundantly present in synovial fluid (SF), is thought to have crucial impact on the functional rheological and biochemical features of SF in healthy and osteoarthritic joints. Here we present comparative measurements of HA concentration in SF from 35 normal and osteoarthritic equine joints, between two different approaches. On the one hand, an established biochemical HA-specific Enzyme–Linked Immunosorbent Assay (ELISA) assay was employed, which determined that SF in healthy and osteoarthritic equine joints is characterized by HA concentration of ca 0.3–2 mg/mL and 0.1–0.7 mg/mL respectively. On the other hand the same SF samples were also examined with a new exploratory approach of finding out HA concentration, which is based on SF rheology. This was done following “calibration” using appropriate model HA solutions. Comparative analysis of the results obtained by both the biochemical and the rheological approaches, revealed that in most cases the rheological approach greatly overestimates HA concentration in SF, by ca 3 to 8 times and 6 to 11 times, in healthy and diseased SF respectively. Overall these findings support the notion that, contrary to the established view, HA may not be the major contributor of equine SF rheology. This should be taken into account for the development of new more effective preventive strategies, as well as more effective early-stage interventions in osteoarthritis.

2006 ◽  
Vol 14 (1) ◽  
pp. 36-43 ◽  
Author(s):  
Binggong Chang ◽  
Xin Cheng ◽  
Shaoman Yin ◽  
Tao Pan ◽  
Hongtao Zhang ◽  
...  

ABSTRACT We have developed a sensitive in vitro assay for detecting disease-associated prion aggregates by combining an aggregation-specific enzyme-linked immunosorbent assay (AS-ELISA) with the fluorescent amplification catalyzed by T7 RNA polymerase technique (FACTT). The new assay, named aggregation-specific FACTT (AS-FACTT), is much more sensitive than AS-ELISA and could detect prion aggregates in the brain of mice as early as 7 days after an intraperitoneal inoculation of PrPSc. However, AS-FACTT was still unable to detect prion aggregates in blood of infected mice. To further improve the detection limit of AS-FACTT, we added an additional prion amplification step (Am) and developed a third-generation assay, termed Am-A-FACTT. Am-A-FACTT has 100% sensitivity and specificity in detecting disease-associated prion aggregates in blood of infected mice at late but still asymptomatic stages of disease. At a very early stage, Am-A-FACTT had a sensitivity of 50% and a specificity of 100%. Most importantly, Am-A-FACTT also detects prion aggregates in blood of mule deer infected with the agent causing a naturally occurring prion disease, chronic wasting disease. Application of this assay to cattle, sheep, and humans could safeguard food supplies and prevent human contagion.


1994 ◽  
Vol 72 (01) ◽  
pp. 089-091 ◽  
Author(s):  
P de Moerloose ◽  
Ph Minazio ◽  
G Reber ◽  
A Perrier ◽  
H Bounameaux

SummaryD-dimer (DD), when measured by a quantitative enzyme-linked immunosorbent assay (ELISA), is a valuable test to exclude venous thromboembolism (VTE). However, DD ELISA technique is not appropriate for emergency use and the available agglutination latex assays are not sensitive enough to be used as an alternative to rule out the diagnosis of VTE. Latex assays could still be used as screening tests. We tested this hypothesis by comparing DD levels measured by ELISA and latex assays in 334 patients suspected of pulmonary embolism. All but one patient with a positive (DD ≥500 ng/ml) latex assay had DD levels higher than 500 ng/ml with the ELISA assay. Accordingly, ELISA technique could be restricted to patients with a negative result in latex assay. This two-step approach would have spared about 50% of ELISA in our cohort. In conclusion, our data indicate that a latex test can be used as a first diagnostic step to rule out pulmonary embolism provided a negative result is confirmed by ELISA and the performance of the latex assay used has been assessed properly.


Author(s):  
Menghan TAO ◽  
Ning XIAO ◽  
Xingfu ZHAO ◽  
Wenbin LIU

New energy vehicles(NEV) as a new thing for sustainable development, in China, on the one hand has faced the rapid expansion of the market; the other hand, for the new NEV users, the current NEVs cannot keep up with the degree of innovation. This paper demonstrates the reasons for the existence of this systematic challenge, and puts forward the method of UX research which is different from the traditional petrol vehicles research in the early stage of development, which studies from the user's essence level, to form the innovative product programs which meet the needs of users and being real attractive.


Author(s):  
Ting Wan Tan ◽  
Han Ling Tan ◽  
Man Na Chang ◽  
Wen Shu Lin ◽  
Chih Ming Chang

(1) Background: The implementation of effective control measures in a timely fashion is crucial to control the epidemic outbreak of COVID-19. In this study, we aimed to analyze the control measures implemented during the COVID-19 outbreak, as well as evaluating the responses and outcomes at different phases for epidemic control in Taiwan. (2) Methods: This case study reviewed responses to COVID-19 and the effectiveness of a range of control measures implemented for epidemic control in Taiwan and assessed all laboratory-confirmed cases between 11 January until 20 December 2020, inclusive of these dates. The confirmation of COVID-19 infection was defined as the positive result of a reverse-transcriptase–polymerase-chain-reaction test taken from a nasopharyngeal swab. Test results were reported by the Taiwan Centers for Disease Control. The incidence rate, mortality rate, and testing rate were compiled, and the risk ratio was provided to gain insights into the effectiveness of prevention measures. (3) Results and Discussion: This study presents retrospective data on the COVID-19 incidence rate in Taiwan, combined with the vital preventive control measures, in a timeline of the early stage of the epidemic that occurred in Taiwan. The implementation of multiple strategy control measures and the assistance of technologies to control the COVID-19 epidemic in Taiwan led to a relatively slower trend in the outbreak compared to the neighboring countries. In Taiwan, 766 confirmed patients were included, comprised of 88.1% imported cases and 7.2% local transmission cases, within the studied period. The incidence rate of COVID-19 in Taiwan during the studied period was 32 per million people, with a mortality rate of 0.3 per million people. Our analysis showed a significantly raised incidence risk ratio in the countries of interest in comparison to Taiwan during the study period; in the range of 1.9 to 947.5. The outbreak was brought under control through epidemic policies and hospital strategies implemented by the Taiwan Government. (4) Conclusion: Taiwan’s preventive strategies resulted in a drastically lower risk for Taiwan nationals of contracting COVID-19 when new pharmaceutical drug or vaccines were not yet available. The preventive strategies employed by Taiwan could serve as a guide and reference for future epidemic control strategies.


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 353
Author(s):  
Ha Eun Jeon ◽  
Hyun Mi Kang ◽  
Eun Ae Yang ◽  
Hye Young Han ◽  
Seung Beom Han ◽  
...  

The aim of the present study is to re-evaluate the clinical application of two-times serologic immunoglobulin M (IgM) tests using microparticle agglutination assay (MAA), an enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR) assay in diagnosing Mycoplasma pneumoniae (MP) infection. A retrospective analysis of 62 children with MP pneumonia during a recent epidemic (2019–2020) was conducted. The MAA and ELISA immunoglobulin M (IgM) and IgG measurements were conducted twice at admission and around discharge, and MP PCR once at presentation. Diagnostic rates in each test were calculated at presentation and at discharge. The seroconverters were 39% (24/62) of patients tested by MAA and 29% (18/62) by ELISA. At presentation, the diagnostic positive rates of MAA, ELISA, and PCR tests were 61%, 71%, and 52%, respectively. After the second examination, the rates were 100% in both serologic tests. There were positive correlations between the titers of MAA and the IgM values of ELISA. The single serologic IgM or PCR tests had limitations to select patients infected with MP in the early stage. The short-term, paired IgM serologic tests during hospitalization can reduce patient-selection bias in MP infection studies.


Behaviour ◽  
1991 ◽  
Vol 119 (1-2) ◽  
pp. 1-29 ◽  
Author(s):  
Kyra Garnetzke-Stollmann ◽  
Dierk Franck

AbstractSpectacled parrotlets live in a complex system of individual relationships throughout their lives. The adults form exclusive pair bonds, addressing all friendly and sexual behaviour patterns to each other. Pair mates cooperate in agonistic situations. As long as they stay close together they hold the same rank-order position. In mate-choice experiments females (not males) significantly preferred a mate which formerly held a high social position. There are also non-exclusive pair bonds, which are far less stable than exclusive ones. Only exclusive pairs have a good chance to occupy a breeding cavity. All group members are synchronized in many of their activities, such as foraging, preening or resting. They are keenly interested in unusual activities of other group members. Social learning, including copying sexual techniques, seems to be essential. After fledging the parents keep their offspring at a distance from a very early stage. Instead of a close parent-offspring relationship the fledglings form sibling groups with their nest mates. Over a period of months siblings remain the main interaction partners for all friendly and playful activities. They also support one another in agonistic situations. In the first months of life even courtship feeding and sexual behaviour are addressed predominantly to siblings. Thus a pair-like relationship is established between siblings, anticipating the permanent pair bond of adults. Single fledglings, deprived of the experience of a sibling group, remained poorly integrated into the group. They developed alternative socialisation tactics, namely (1) joining a host group of unrelated siblings, (2) renewing a friendly partnership with the parents, (3) helping to protect and feed younger siblings or even unrelated fledglings and (4) seeking early partnership with unrelated group members. Out of 10 single fledglings only the one that was accepted by a host sibling group immediately after fledging became well integrated into the whole group and reproduced well. It is argued that sibling groups offer good opportunities for learning partnership and function as a safe basis for exploring the social environment. It is tentatively proposed that single fledglings have a decreased probability of reproductive success.


2007 ◽  
Vol 50 (2) ◽  
pp. 349-359 ◽  
Author(s):  
Simone Fujii ◽  
Elisabete Yurie Sataque Ono ◽  
Ricardo Marcelo Reche Ribeiro ◽  
Fernanda Garcia Algarte Assunção ◽  
Cássia Reika Takabayashi ◽  
...  

An indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) for ochratoxin A (OTA) detection in green, roasted and instant coffees was developed using anti-OTA monoclonal antibody. Immunological reagents prepared were OTA-BSA (4.76 mg/mL), anti-OTA.7 MAb (2x10³-fold dilution) and HRP-anti IgG (10³-fold dilution). The detection limit was 3.73 ng OTA/g and correlation coefficients (r) between this immunoassay and high performance liquid chromatography were 0.98 for green coffee, 0.98 for roasted and 0.86 for instant. OTA levels detected by ic-ELISA were higher than by HPLC, with ELISA/HPLC ratio of 0.66 - 1.46 (green coffee), 0.96 - 1.11 (roasted) and 0.93 - 1.82 (instant). ELISA recoveries for OTA added to coffee (5 - 70 ng/g) were 81.53 % for green coffee, 46.73 % for roasted and 64.35 % for instant, while recoveries by HPLC were 80.54 %, 45.91 % and 55.15 %, respectively. Matrices interferences were minimized by samples dilution before carrying out the ELISA assay. The results indicate that MAb-based ic-ELISA could be a simple, sensitive and specific screening tool for OTA detection, contributing to quality and safety of coffee products.


2018 ◽  
Vol 81 (10) ◽  
pp. 1723-1728 ◽  
Author(s):  
STEVE L. TAYLOR ◽  
JULIE A. NORDLEE ◽  
SHYAMALI JAYASENA ◽  
JOSEPH L. BAUMERT

ABSTRACT A portable, handheld gluten detection device, the Nima sensor, is now available for consumers wishing to determine if gluten is present in food. By U.S. regulation, gluten-free foods should contain <20 ppm of gluten. Thirteen gluten-free foods (muffins, three different types of bread, three different types of pasta, puffed corn snack, ice cream, meatballs, vinegar and oil salad dressing, oatmeal, and dark chocolate) were prepared; each food was spiked on a weight to weight basis with gluten levels of 0, 5, 10, 20, 30, 40, and 100 ppm before processing or preparation. Unprocessed and processed foods were tested with the handheld gluten sensor and by two gluten-specific enzyme-linked immunosorbent assays (ELISAs) on the basis of the R5 and G12 monoclonal antibodies, respectively. The portable gluten detection device detected gluten in all food types at the 30-ppm addition level, failing to detect gluten in only 5 (6.4%) of 78 subsamples. At the 20-ppm addition level, the portable gluten detection device failed to detect gluten in one type of pasta but detected gluten residues in 63 (87.5%) of 72 other subsamples. The device was able to detect gluten at the 10-ppm addition level in 9 of the 13 food matrices (41 of 54 subsamples, 75.9%) but not in the three types of pasta and the puffed corn snack. The gluten-sensing device did not perform reliably at the 5-ppm addition level in 11 of 13 food matrices (exceptions: ice cream and muffins). In contrast, the ELISA methods were highly reliable at gluten addition levels of ≥10 ppm in all food matrices. The portable gluten detection device yielded a low percentage of false-positive results (4 of 111, 3.6%) in these food matrices. Thus, this handheld portable gluten sensor performed reliably in the detection of gluten in foods having ≥20 ppm of added gluten with only 18 (5.9%) of 306 failures, if results of the one type of pasta are excluded. The device worked with greater reliability as the gluten levels in the foods increased.


2021 ◽  
Vol 292 ◽  
pp. 03084
Author(s):  
Suke Liu

Salmonella is a pathogenic Gram-negative bacterium and important zoonotic pathogen survive in host cell, which is well known to cause gastrointestinal infections and even death in human through food contamination. Salmonella survives and reproduces within cells in two forms of cytosolic Salmonella and vacuolar Salmonella. However, the current researches on the mechanism of Salmonella infection was mostly based on the total numbers, and there is no clear distinction between cytosolic Salmonella and vacuolar Salmonella. This article combined biotin-streptavidin-amplified enzyme-linked immunosorbent assay(BA-ELISA) and Flat colony counting method to separate and quantify cytosolic Salmonella and vacuolar Salmonella. The results showed that the anti-Salmonella antibody with a dilution ratio of 1:500 can bind ~1700 Salmonella, and the binding rate reached to~70%. In terms of bacterial counts, vacuolar Salmonella dominates in the early stage of Salmonella infection, and cytosolic Salmonella dominates in the later stage, the reproduction rate of vacuolar Salmonella is significantly lower than cytosolic Salmonella during Salmonella infection, the dynamic growth curve of cytosolic Salmonella and vacuolar Salmonella intuitively reflected the proliferation status of the two forms of Salmonella during the entire process of Salmonella infection.


Sign in / Sign up

Export Citation Format

Share Document