scholarly journals Indoor Air Quality and Potential Health Risk Impacts of Exposure to Antibiotic Resistant Bacteria in an Office Rooms in Southern Poland

Author(s):  
Ewa Brągoszewska ◽  
Izabela Biedroń

The aims of this article are to characterize: the quantity of culturable bacterial aerosol (QCBA) and the quality of culturable bacterial aerosol (QlCBA) in an office building in Southern Poland during the spring. The average concentration of culturable bacterial aerosol (CCBA) in this building ranged from 424 CFU m−3 to 821 CFU m−3, below Polish proposals for threshold limit values. Size distributions were unimodal, with a peak of particle bacterial aerodynamic diameters less than 3.3 μm, increasing potentially adverse health effects due to their inhalation. The spring office exposure dose (SPED) of bacterial aerosol was estimated. The highest value of SPED was in April (218 CFU kg−1), whereas the lowest was in June (113 CFU kg−1). Analysis was undertaken to determine the antibiotic resistance of isolated strains and their ability to form biofilms, which may facilitate the spread of antibiotic resistance genes. In the course of the study, it was found that Staphylococcus xylosus had the greatest ability to form biofilms, while the strains with the highest antibiotic resistance were Micrococcus luteus D and Macrococcus equipercicus. Given that mainly antibiotic-sensitive bacteria from bioaerosol were isolated, which transfers resistance genes to their plasmids, this shows the need for increased monitoring of indoor air quality in workplaces.

2020 ◽  
Vol 8 (2) ◽  
pp. 202 ◽  
Author(s):  
Ewa Brągoszewska ◽  
Izabela Biedroń ◽  
Wojciech Hryb

International interests in biological air pollutants have increased rapidly to broaden the pool of knowledge on their identification and health impacts (e.g., infectious, respiratory diseases and allergies). Antibiotic resistance and its wider implications present us with a growing healthcare crisis, and an increased understanding of antibiotic-resistant bacteria populations should enable better interpretation of bioaerosol exposure found in the air. Waste sorting plant (WSP) activities are a source of occupational bacterial exposures that are associated with many health disorders. The objectives of this study were (a) to assess bacterial air quality (BAQ) in two cabins of a WSP: preliminary manual sorting cabin (PSP) and purification manual sorting cabin (quality control) (QCSP), (b) determine the particle size distribution (PSD) of bacterial aerosol (BA) in PSP, QCSP, and in the outdoor air (OUT), and (c) determine the antibiotic resistance of isolated strains of bacteria. Bacterial strains were identified on a Biolog GEN III (Biolog, Hayward, CA, USA), and disc diffusion method for antimicrobial susceptibility testing was carried out according to the Kirby–Bauer Disk Diffusion Susceptibility Test Protocol. A large share of fecal bacteria, Enterococcus faecalis and Alcaligenes faecalis spp. feacalis, was found in the tested indoor air, which is a potential health hazard to the workers of the monitored WSP. Our results demonstrate the necessity to take into account fecal air pollution levels to avoid making erroneous assumptions regarding the environmental selection of antibiotic resistance. Total elimination of many anthropogenic sources is not possible, but important findings of this study can be used to develop realistic management policies methods to improve BAQ.


2018 ◽  
Vol 7 (3.9) ◽  
pp. 42
Author(s):  
Norsafiah Norazman ◽  
Adi Irfan Che Ani ◽  
Nor Haslina Ja’afar ◽  
Muhamad Azry Khoiry

Indoor Air Quality (IAQ) is an essential matter in achieving students’ satisfaction for the learning process. Building’s orientation is a factor that may encourage sufficient natural ventilation for the classroom occupants. Inadequate ventilation is an issue for most existing classrooms. The purpose of this paper is to analyze the accuracy of natural ventilation in classrooms. Therefore, experimental on 20 classrooms has been conducted by using Multipurpose Meter at secondary school buildings in Malaysia. The findings indicated that the accuracy of natural ventilation testing was below the permissible limits throughout the hours monitored, thus this may cause potential health hazards to the students. Temperature and air flow rates were lower than 23 °C and 0.15 m/s respectively, it fulfilled the basic requirements as a standard learning environment. However, measurements taken showed the overall relative humidity (RH) in the classrooms can be categorized as acceptable with 40% to 70% range. On the basis of these findings, it is evident that naturally ventilated classrooms are important especially due to energy efficiency, whereas mechanical ventilation should only be installed as an alternative under extremely hot weather conditions.   


Atmosphere ◽  
2019 ◽  
Vol 10 (12) ◽  
pp. 742 ◽  
Author(s):  
Ewa Brągoszewska ◽  
Magdalena Bogacka ◽  
Krzysztof Pikoń

Air pollution, a by-product of economic growth, generates an enormous environmental cost in Poland. The issue of healthy living spaces and indoor air quality (IAQ) is a global concern because people spend approximately 90% of their time indoors. An increasingly popular method to improve IAQ is to use air purifiers (APs). Indoor air is often polluted by bioaerosols (e.g., viruses, bacteria, fungi), which are a major concern for public health. This work presents research on culturable bacterial aerosol (CBA) samples collected from dwellings with or without active APs during the 2019 summer season. The CBA samples were collected using a six-stage Andersen cascade impactor (ACI). The CBA concentrations were expressed as Colony Forming Units (CFU) per cubic metre of air. The average concentration of CBA in dwellings when the AP was active was 450–570 CFU/m3, whereas the average concentration when the AP was not active was 920–1000 CFU/m3. IAQ, when the APs were active, was on average almost 50% better than in cases where there were no procedures to decrease the concentration of air pollutants. Moreover, the obtained results of the particle size distribution (PSD) of CBA indicate that the use of APs reduced the proportion of the respirable fraction (the particles < 3.3 µm) by about 16%. Life cycle assessment (LCA) was used to assess the ecological cost of air purification. Our conceptual approach addresses the impact of indoor air pollution on human health and estimates the ecological cost of APs and air pollution prevention policies.


Atmosphere ◽  
2020 ◽  
Vol 11 (8) ◽  
pp. 797 ◽  
Author(s):  
Ewa Brągoszewska ◽  
Izabela Biedroń ◽  
Anna Mainka

The benefits of regular exercise include improved physical and mental health. The school gym is a particular micro-environment where students perform intensive physical training. The question is if there is an increased risk of microbiological contamination. This preliminary work studied the exposure of students to bacterial aerosol (BA) in a highschool gym located in an urban area of Southern Poland. A sampling of BA was undertaken with an Andersen six-stage impactor (ANDI). BA was identified using API (analytical profile index) tests. The BA concentrations were expressed as Colony Forming Units (CFU) per cubic metre of air. The results showed that before gym classes (BGC), the concentration of BA was 4.20 × 102 ± 49.19 CFU/m3, while during gym classes (DGC), the level of BA more than doubled (8.75 × 102 ± 121.39 CFU/m3). There was also an increase in the respirable fraction of BA (particles less than 3.3 µm). Before the start of the sports activities, respirable fraction accounted for 30% of the BA, while during physical education classes, this share increased to over 80%. Identification of BA species showed that the dominant group of bacteria in the indoor air of the gym BGC was Gram-positive rods (61%) and for DGC it was Gram-positive cocci (81%). We detected that one bacteria strain (Corynebacterium striatum) was classified into risk group 2 (RG2) according to Directive 2000/54/EC. Additionally, multi-antibiotic resistance (MAR) showed that among the isolated airborne bacteria, the highest antibiotic resistance was demonstrated by Staphylococcus epidermis (isolated DGC) and Pseudomonas sp. (isolated BGC). The quantitative and qualitative information on microbiological air quality (MIAQ) in the school gym indicates that the actions to improve indoor physical activity spaces are recommended.


Author(s):  
Haruna Musa Moda ◽  
Debrah King

Because of exposure to a number of potential health hazards within the work environment, hairstylists experience occupational diseases that include occupational asthma, skin conditions and musculoskeletal diseases. The paucity of studies assessing occupational safety and hygiene management among Afro-Caribbean hair salon operators in the UK promoted the study. QualtricsTM was used to assess the participants’ perception of exposure to hair products and their personal safety and hygiene knowledge, attitudes, awareness, and risk perceptions at work. In five salons, indoor air quality was monitored over one working week for selected environmental pollutants: temperature, humidity, CO, CO2 and Total Volatile Organic Compounds (TVOCs) using a GrayWolf Direct Sense Indoor Air Quality-IAQ (IQ-610). The use of unflued gas heating to raise the indoor temperature was common among the salons’ operators which explains the high carbon monoxide readings recorded. Itchy eyes and nose (44.4%) shoulder, neck and back pain (39.2%) were frequently reported. Age-stratified analysis of reported occupational ailments showed participants within an age bracket of 31–35 reported allergies (24%) and itchy eyes and nose (19.1%) as the most common of occupational ailments. Respiratory, skin and musculoskeletal symptoms ranked as major occupational ill-health experiences among the study population. The study outcome demonstrated that the type of activity and the hair products used play an important role in the level of pollutants in the working environment. The substitution of the more harmful hair products with safer alternatives is needed, as is the encouragement of health surveillance.


2015 ◽  
Vol 773-774 ◽  
pp. 1068-1072 ◽  
Author(s):  
Chin Ming Er ◽  
N.M. Sunar ◽  
Abdul Mutalib Leman ◽  
Norzila Othman ◽  
Q. Emparan ◽  
...  

The proliferation of indoor airborne microorganism in public institutional buildings such as schools and universities is often regarded as a potential health hazards to the buildings’ users. This issue is not new in Malaysia, a country with humid climate which favours the growth of microorganism. However, there is lack of research’s data, especially in higher institutional buildings in this country. The assessment of the indoor air quality is conducted in a university’s two new commissioning buildings located at Southern Peninsular of Malaysia. Both buildings utilized centralized air conditioning system. Concentrations of airborne microorganism were determined using a single-stage impacter (biosampler) as per requirement of National Institute of Occupational Safety and Health (NIOSH) Manual Analytical Method 0800. The acquired readings were compared to the standard level determined in Industry Code of Practice on Indoor Air Quality (ICOP IAQ) 2010. Other parameters such as relative humidity, temperature, and air velocity were recorded along the assessment. The mean concentrations of the total bacteria at the affected area of the two buildings are 1102.5 CFU/m3 and 813 CFU/m3 respectively and it is significantly higher compared to the maximum exposure limit of 500 CFU/m3. While, the mean concentration of total fungi at the affected area for two buildings are 805.7 CFU/m3 and 509 CFU/m3 respectively which are both higher than the reading of outdoors and unaffected indoor area although slightly lower than the maximum exposure limit of 1000 CFU/m3. This study provides a glance of the poor indoor microbiological air quality in new higher institutional buildings in this humid region.


2013 ◽  
Vol 10 (2) ◽  
pp. 209-216

A field study on the impact of fireplace on the indoor air quality was carried out between 2004 and 2006, where two main contaminants, CO and particulate matters, were investigated in twenty seven randomly selected Irish houses. The results show that while the physical environment has been improved by increasing the room air and radiant temperature, indoor air quality is significantly decreased when fireplace is used as additional heating source to the central heating. The operation of fireplace increased transient concentrations of CO and airborne particle to several times higher than the normal house average level. Statistical analysis showed significant difference of the average PM10 concentration between house groups with and without using fireplace. However fireplace did not demonstrate a significant influence on average CO level from our samples. When comparisons were made between houses with various emission sources, i.e. fireplace, smoking and open fire gas cooking, and houses free of the above sources, smoking and open fire gas cookers were proved to be other major sources of particles and CO. Particularly when they exist at the same time with fireplace, significant elevation of CO and airborne particle levels is observed in analysis. Cumulative probability analysis in some houses revealed high percentage of time exceeding health guidelines which indicated the potential health risk in these houses. Mass balance equation was employed to estimate particle emission rates from fireplace, namely 0.66 mg min-1 (PM10) and 0.20 mg min-1 (PM2.5) respectively in terms of mass concentration. Emission rates on particle numbers were also estimated despite the relatively smaller sample. Gas fuel fireplaces tended to emit fewer particles both in mass and in number comparing to fireplaces using solid fuels.


1996 ◽  
Vol 4 (2) ◽  
pp. 91-99 ◽  
Author(s):  
Thad Godish

Theoretical and reported impacts of infiltration-reducing energy conservation measures on indoor air quality in residential buildings are reviewed. Though it is widely held that energy conservation measures either cause or contribute to indoor air pollution and possible adverse health effects, the relationship is a relatively complex one. Potential effects of energy conservation measures depend on the nature of individual contaminants, their sources, and responses to changes in infiltration and ventilation conditions. For contaminants such as formaldehyde, volatile organic compounds, and radon, infiltration-reducing energy conservation measures appear to have limited effects on contaminant levels and potential health risks. Moisture is a major concern because decreased ventilation associated with energy conservation measures may result in increased indoor water vapor levels that may provide a favorable environment for allergen-producing dust mites and mold, as well as structural damage. As with other contaminants, the relationship between energy conservation measures and indoor moisture levels is relatively complex.Key words: infiltration, ventilation, indoor air quality, energy conservation, radon, formaldehyde.


Sign in / Sign up

Export Citation Format

Share Document