scholarly journals Evidence of a Down Syndrome Keratopathy: A Three-Dimensional (3-D) Morphogeometric and Volumetric Analysis

2021 ◽  
Vol 11 (2) ◽  
pp. 82
Author(s):  
Ibrahim Toprak ◽  
Francisco Cavas ◽  
Alfredo Vega ◽  
José S. Velázquez ◽  
Jorge L. Alio del Barrio ◽  
...  

The aim of this study was to investigate whether a different and abnormal corneal profile is present in Down syndrome (DS) by personalized three-dimensional (3D) modelling. This single-centre cross-sectional study included 43 patients with DS (43 eyes) and 58 age-sex-matched control subjects (58 eyes) with normal karyotype and topography. Refraction, central corneal thickness (CCT), aberrations (high-order, coma and spherical), asphericity and morphogeometric/volumetric parameters based on a 3D corneal model that was generated from raw topographical data were evaluated. Deviation of anterior/posterior apex (Dapexant/Dapexpost) and thinnest point (Dmctant/Dmctpost) from corneal vertex, anterior/posterior surface area (Aant/Apost), sagittal area passing through the anterior/posterior apex (Aapexant/Aapexpost) and thinnest point (Amctpost), total corneal volume (Vtotal) and volumetric progression for each 0.05 mm step of the radius value centred to the thinnest point (VOLMCT) and anterior/posterior apex (VOLAAP/VOLPAP) comprised the morphogeometric/volumetric parameters. In the DS group, 58.1% of the eyes presented abnormal topography. High-order and coma aberrations, asphericity, Dapexant, Aant, Apost and Aapexant were significantly higher, whereas CCT, Aapexpost, Amctpost, Vtotal, VOLAAP, VOLPAP and VOLMCT were lower in the DS group than in the control group (p < 0.05). Dapexpost did not differ between the groups (p > 0.05). This study demonstrates that corneas of the subjects with DS are different and more aberrated than those of normal age- and sex-matched non-DS controls. Anterior corneal apex appears to be displaced in DS even with normal topography, while posterior apex seems stable although topography is abnormal. These findings may help to modify our approach in the diagnosis of keratopathy in subjects with DS.

2016 ◽  
Vol 15 (2) ◽  
Author(s):  
Paaraj Dave ◽  
Jitendra Jethani

Purpose: To report the repeatability of Pattern Electrotretinogram (PERG) and its findings in ocular hypertension (OHT) and normal eyes.Methods: A cross-sectional study where PERG responses were compared between the study group comprising of 80 eyes of 80 patients with intraocular pressure (IOP)>21 mmHg and the control group with 80 eyes of 80 normal individuals (IOP≤21mmHg). The optic disc and the visual fields were normal with a visual acuity of ≥ 0.8 in both groups. PERG was recorded twice for each individual in the control group by a single operator on 2 consecutive days to assess the repeatability.Results: The mean age in the study and control groups was 50.05±10.03 and 54.8±7.66 years(p=0.44) respectively. The mean IOP was 26.55±3.9 mmHg for the study group as opposed to 14.45±2.9 mmHg for the controls (p<0.001). The central corneal thickness and the cup-disc ratio was similar between the groups (p>.05). The P50-N95 amplitude (p=0.01) and the P50 latency (p<0.001) was statistically significantly different between both the groups. The intra-class correlation coefficient (ICC) showed poor agreement for all parameters except for N35-P50 0.8 to 16 degree check size amplitude ratio (PERG ratio).Conclusion:  Increase in P50 latency emerges as a new candidate for early glaucoma indicator in addition to reduction in P50-N95 amplitude. PERG parameters suffer from high test-retest variability. Deterioration in PERG recordings should be interpreted with caution. The variability is lesser for the PERG ratio which maybe more meaningful while monitoring for change over time.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Davide Cavagnetto ◽  
Andrea Abate ◽  
Alberto Caprioglio ◽  
Paolo Cressoni ◽  
Cinzia Maspero

Abstract Background There is currently no information on how different mandibular segments are affected by juvenile idiopathic arthritis. The aim of this paper is to assess volumetric differences of different mandibular segments in subjects with unilateral and bilateral JIA and to compare them with non-JIA control volumes. Materials and methods Forty subjects with unilateral TMJ involvement and 48 with bilateral TMJ involvement were selected for the case group and 45 subjects with no known rheumatic comorbidities for the control group. The mandible of each subject was divided according to a validated method into different paired volumes (hemimandible, condyle, ramus and hemibody). Results The ANOVA test revealed a statistically significant difference in all the groups for condylar and ramus volumes, and the pairwise comparison evidenced a statistically significant higher condylar and ramus volume in the control group (1444.47 mm3; 5715.44 mm3) than in the affected side in the unilateral JIA group (929.46 mm3; 4776.31 mm3) and the bilateral JIA group (1068.54 mm3; 5715.44 mm3). Moreover, there was also a higher condylar volume in the unaffected side in the unilateral JIA group (1419.39 mm3; 5566.24 mm3) than in the bilateral JIA group and the affected side in the unilateral JIA group. Conclusions The affected side of unilateral JIA patients showed statistically significant lower volumes in the hemimandible, in the condyle and in the ramus. The largest total mandibular volume was observed in the control group, followed by the unilateral JIA group and, lastly, by the bilateral JIA group.


CRANIO® ◽  
2018 ◽  
Vol 38 (5) ◽  
pp. 320-326 ◽  
Author(s):  
Alessandro Nota ◽  
Silvia Caruso ◽  
Shideh Ehsani ◽  
Alberto Baldini ◽  
Simona Tecco

2020 ◽  
pp. 112067212097202
Author(s):  
Maria J Vieira ◽  
Joana Pereira ◽  
Miguel Castro ◽  
Henrique Arruda ◽  
Joana Martins ◽  
...  

Purpose: The aim of the present study is to calculate Concavity Shape Index (CSI) in patients with POAG and exfoliative glaucoma (XFG) and correlate CSI with the severity of glaucoma, comparing to control and ocular hypertension (OHT) patients. Methods: This was a cross‑sectional study with 146 eyes/146 subjects: 37 healthy eyes, 23 eyes with OHT and 86 glaucoma eyes (70 with POAG, 16 with XFG). The severity of glaucoma was scored with the Glaucoma Staging System 2 (GSS2). Corvis ST® was used to calculate CSI. Results: Central corneal thickness (CCT) was significantly thinner in POAG (526 ± 40.0 µm) and XFG (520 ± 38.2 µm) than control group (553 ± 28.8 µm). CSI had no significant differences between the groups. XFG had a higher mean of GSS 2 (2.42 ± 1.38) than POAG (1.87 ± 1.55) and OHT (1.87 ± 1.55). OHT had a significantly less deformable cornea than: control (higher A1 length, lower A1 velocity, higher A2 velocity), POAG (higher A1 length, lower A1 velocity, lower deflection amplitude at highest concavity), and XFG group (lower A1 velocity, lower deflection amplitude at highest concavity), which was independent of age and CCT. No significant correlation was found between GSS 2 and CSI. Discussion: OHT patients had stiffer corneas (less deformed by the air puff) when compared to control, POAG or XFG patients. A less deformable cornea could potentially be related to a more resistant LC/peripapillary sclera. As such, this would result in a lesser optic nerve susceptibility to IOP damage.


2020 ◽  
Author(s):  
Zhe Li ◽  
Guanzhi Liu ◽  
Run Tian ◽  
Ning Kong ◽  
Yue Li ◽  
...  

Abstract Our objective was to obtain normal patellofemoral measurements so as to provide a reference for prosthetic design. Besides, the absolute values and indices of TT-TG distances are still controversial in clinical application. A better method to enable precise clinical applications is still needed.Methods:78 knees of 78 subjects without knee pathologies were included in this cross-sectional study. A CT scan was obtained from all subjects and three-dimensional knee models were constructed using Mimics and SolidWorks software. We measured and analyzed 19 parameters including TT-TG distance and dimensions and shapes of patella, femur, tibia, and trochlea. LASSO regression was used to predict the normal TT-TG distances.Results:The dimensional indexes, TT-TG distance, and femoral aspect ratio of the males were significantly larger than those of females (all P values <0.05). However, after controlling the bias from age, height, and weight, there were no significant differences in TT-TG distances, PAL, and anterior-posterior dimensions between genders (all P values >0.05). The Pearson correlation coefficients between the AFO and other indexes were consistently below 0.3, indicating a none or weak relationship. Similar results were observed for the SA and the Wiberg index. Using LASSO regression, we obtained four parameters to predict TT-TG distance (R2=0.5612, P<0.01) to achieve the optimal accuracy and convenience. Conclusion:The anterior-posterior dimensions of the females were thicker than those of males for the same medial-lateral dimensions. More attention should be paid to not only gender differences but individual differences, especially the anterior condyle and trochlea. Besides, this study provided a new method of predicting TT-TG distance to enable precise clinical diagnoses and guide the medial transfer of the tibial tuberosity.


2020 ◽  
Vol 9 (8) ◽  
Author(s):  
Marina Fuzette Amaral ◽  
Karina Helga Turcio de Carvalho ◽  
Alessandra Marcondes Aranega ◽  
Caio Vinicius Lourenço Debortoli ◽  
Gabriela Baesteiro Baldessim ◽  
...  

The act of caring, being responsible for the survival and quality of life of others, represent extra activities that can cause socio-emotional changes to those who perform this function. Objective: To assess the quality of life, depression, anxiety and stress of caregivers of people with or without Down syndrome. Methodology: 144 caregivers were divided into Control Group (caregivers of typical children) and Down Syndrome Group (caregivers of people with Down Syndrome). The controlled observational cross-sectional study was prepared in accordance with the Declaration of Helsinki and approved by the Human Ethics Committee. To achieve the objectives, validated questionnaires related to the theme were applied. The data were subjected to the Chi-square test with modified Bonferroni post hoc and Rank or Pearson correlation tests. Results: The Down Syndrome Group had a lower quality of life related to the psychological domain and a higher environmental domain than the Control Group. In the groups studied, quality of life and family income showed a positive correlation (p = 0.02) and there was no difference in depression. The Control Group had a higher rate of anxiety and the Down Syndrome Group had a higher rate of physical symptoms of stress; correlated with the degree of dependence of the Down Syndrome patient (p = 0.04). Conclusion: Family income is an important factor for a better quality of life, symptoms of physical stress reduce the quality of life in the psychological domain and symptoms of physical stress of caregivers are correlated with a greater degree of dependence of patients with Down Syndrome.


2020 ◽  
Vol 13 (12) ◽  
pp. 1922-1927
Author(s):  
Sara Garcia Caride ◽  
Federico Sáenz Francés ◽  
Julián García Feijoo

AIM: To study of corneal biomechanical properties and intraocular pressure (IOP) measured with Corvis Scheimpflug Technology (ST) in patients with childhood glaucoma (CG). METHODS: Cross-sectional study in which 89 eyes were included 56 of them with CG. Only one eye per patient was included. The following variables were obtained from the clinical history and the ophthalmological examination: age, sex, IOP, number of surgeries, and the cup/disc ratio (CDR). The following parameters were recorded using Corvis ST: corrected by biomechanics IOP (bIOP), not corrected IOP (nctIOP), central corneal thickness (CCT), maximum concavity [radius, peak distance (PD) and deformation amplitude], applanation 1 and 2 (length and velocity). The mean age was 23±14.55 and 33±19.5 years old for the control group and CG group, respectively. Totally 36 were males and 53 were females. In the CG group, 7 patients were controlled only with medical treatment. Sixteen had at least one previous goniotomy, 19 had at least one trabeculectomy, and 11 had an Ahmed implant. RESULTS: A significant and positive intraclass correlation coefficient was found between Goldman IOP and the IOP measured by Corvis in both groups. No differences were found between the IOP measured with Corvis and Goldman using a student t-test. Regarding biomechanical parameters, there were differences in the applanation length 2 (A-L2), in the applanation velocity 2 (A-V2) and in the PD. By sex, only the applanation length 1 (A-L1) was found to be different in control group. A positive and significant Pearson correlation was found between CDR and the A-L1. CONCLUSION: Corneal biomechanical properties have shown differences between CG and healthy subjects and also between men and women.


Author(s):  
Kashish Narula ◽  
Narendra Kumar Dara ◽  
Shyam Lal Meena

Background: Thyroid hormones influence nearly all major metabolic pathways. Their most obvious and well-known action is the increase in basal energy expenditure obtained by acting on protein, carbohydrate and lipid metabolism. The lipid metabolism is more influenced by the thyroid hormone. Methods: A cross-sectional study was conducted on 100 patients with suspicion of thyroid disorders were taken as cases. One hundred patients with normal thyroid profile and no history of other chronic diseases were taken as control group. Results: The serum TC, TG and LDL levels in hypothyroid individuals (both overt and subclinical) were significantly higher than euthyroid subjects but the levels were comparable between hyperthyroid and euthyroid group. Conclusion: Dyslipidemias are associated with thyroid disorders, so biochemical screening for thyroid dysfunction in all dyslipidemic patients. Therefore, patients presenting with dyslipidemia are recommended for investigation to explore thyroid dysfunction. Keywords: Thyroid profile, Total cholesterol, Triglycerides and LDL


2013 ◽  
Vol 40 (2) ◽  
Author(s):  
Ni Ketut Susilawati ◽  
Wayan Sudana ◽  
Eka Putra Setiawan

Background: Noise pollution or noise is an unwanted sound which is disturbing to human beings.However small or soft the sound, if it is undesirable it is considered as noise. Noise induced hearingloss is a sensorineural hearing loss that is commonly encountered second to presbycusis. Purpose: Toknow the effect of traffic noise exposure on hearing impairment to the employees of the Parking DistrictCompany of the Denpasar city and to improve diagnostic detection on hearing impairment caused bynoise. Method: A cross sectional study was conducted at the Parking District Company office. Thepopulations of this study were the employees of the Parking District Company. Samples of this study were the employees who were exposed to traffic noise and control samples were an employee who was unexposed. Samples were selected by simple random sampling. Results: From 40 parking attendants,27 persons (67.5%) aged above 35 years old. The parking attendants who had been working for ten to fifteen years were 36 persons (90%) and no history using ear protection when working. Seven persons(17.5%) had referred DPOAE upon examination with increase hearing threshold on audiogram result.In this study the parking attendants who had hearing deficit induced by noise were 7 persons (17.5%)and only one person (2.5%) in control group. There was a statistically significant effect of traffic noiseto hearing function deficit (p<0.05). Conclusion: Traffic noise has effect in hearing function deficit onthe parking attendants.ORLI Vol. 40 No. 2 Tahun 2010Key words: NIHL, parking attendant, audiometry, DPOAE.


2019 ◽  
pp. 68-73
Author(s):  
Trong Nghia Nguyen ◽  
Thi Nhan Nguyen ◽  
Thi Dua Dao

Background: The metabolic syndrome is a constellation of cardiometabolic risk factors that tend to cluster together in affected individuals more often than predicted by chance. The presence of the metabolic syndrome substantially increases the risk of developing type 2 diabetes and cardiovascular disease, and is associated with a range of adverse clinical outcomes, many of which are closely associated with aging. Current estimates suggest that approximately 20 - 25% of the world’s population is affected by the metabolic syndrome. The prevalence of the metabolic syndrome rises with age and more than 45% of people aged over 60 years have the metabolic syndrome. Recent studies show that low vitamin D status is very common in the world and this is a risk factor of metabolic syndrome. Objective: (1) Plasma 25-hydroxyvitamin D concentration in subjects with metabolic syndrome. (2) Cut off value of plasma 25-hydroxyvitamin D concentration for predicting metabolic syndrome. Material and method: A cross-sectional study with control group on 318 adult subjects for health examinations at International Medical Center at Hue Central Hospital, including 139 subjects with metabolic syndrome and control group of 179 healthy subjects. Metabolic syndrome was defined according to the IDF, NHLBI, AHA, WHF, IAS, IASO (2009). Plasma hydroxyvitamin D concentration was measured using chemiluminescent microparticle immunoassay. Reciever operating characteristic (ROC) curve were generated to assess sensitivity and specificity for different cut off value of 25-hydroxyvitamin D concentration for predicting metabolic syndrome. Results: Plasma 25-hydroxyvitamin D concentration in subjects with metabolic syndrome was 26.4 ng/ml, incidence of plasma 25-hydroxyvitamin D deficiency (59.7%) was significantly higher than in control group (23.5%) (p < 0.001). The optimal cut off point for 25-OH-D concentration for predictor of metabolic syndrome as 26.4 ng/ml (AUC=0.657, sensitivity=53.4%, specificity=71.6%). Conclusion: In 139 subjects with metabolic syndrome, the plasma 25-hydroxyvitamin D concentration was 26.4 ng/ml and the incidence of 25-hydroxyvitamin D deficiency in the metabolic syndrome group was 59.7%. The optimal cut off point for plasma 25-hydroxyvitamin D concentration for predictor of metabolic syndrome as 26.4 ng/ml. Key words: Metabolic syndrome, 25-hydroxyvitamin D


Sign in / Sign up

Export Citation Format

Share Document