scholarly journals DNA Printing Integrated Multiplexer Driver Microelectronic Mechanical System Head (IDMH) and Microfluidic Flow Estimation

Micromachines ◽  
2020 ◽  
Vol 12 (1) ◽  
pp. 25
Author(s):  
Jian-Chiun Liou ◽  
Chih-Wei Peng ◽  
Philippe Basset ◽  
Zhen-Xi Chen

The system designed in this study involves a three-dimensional (3D) microelectronic mechanical system chip structure using DNA printing technology. We employed diverse diameters and cavity thickness for the heater. DNA beads were placed in this rapid array, and the spray flow rate was assessed. Because DNA cannot be obtained easily, rapidly deploying DNA while estimating the total amount of DNA being sprayed is imperative. DNA printings were collected in a multiplexer driver microelectronic mechanical system head, and microflow estimation was conducted. Flow-3D was used to simulate the internal flow field and flow distribution of the 3D spray room. The simulation was used to calculate the time and pressure required to generate heat bubbles as well as the corresponding mean outlet speed of the fluid. The “outlet speed status” function in Flow-3D was used as a power source for simulating the ejection of fluid by the chip nozzle. The actual chip generation process was measured, and the starting voltage curve was analyzed. Finally, experiments on flow rate were conducted, and the results were discussed. The density of the injection nozzle was 50, the size of the heater was 105 μm × 105 μm, and the size of the injection nozzle hole was 80 μm. The maximum flow rate was limited to approximately 3.5 cc. The maximum flow rate per minute required a power between 3.5 W and 4.5 W. The number of injection nozzles was multiplied by 100. On chips with enlarged injection nozzle density, experiments were conducted under a fixed driving voltage of 25 V. The flow curve obtained from various pulse widths and operating frequencies was observed. The operating frequency was 2 KHz, and the pulse width was 4 μs. At a pulse width of 5 μs and within the power range of 4.3–5.7 W, the monomer was injected at a flow rate of 5.5 cc/min. The results of this study may be applied to estimate the flow rate and the total amount of the ejection liquid of a DNA liquid.

2012 ◽  
Vol 220-223 ◽  
pp. 539-542
Author(s):  
Hai Feng Xie ◽  
Zhi Gang Yang ◽  
Meng Jie

To improve the driving ability of gas and light fluid which is sensitive to the temperature change, based on the system resonant principle a novel kind of piezoelectric resonant diaphragm air pump has been proposed. Experimental results indicate that the maximum flow rate is 1650ml/min when the sinusoidal AC driving voltage is 200v, the vibrating spring thickness is 0.6mm, the adjusting spring thickness is 1.4mm, and it was 0.5 as the radius ratio of the rigidity transfer vibration piston and the diaphragm.


Author(s):  
Yuchuan Zhu ◽  
Chang Liu ◽  
Yunze Song ◽  
Long Chen ◽  
Yulei Jiang ◽  
...  

In this paper, an electro-hydrostatic actuator driven by dual axial-mounted magnetostrictive material rods-based pumps (MMPs) with a new type of active rectification valve is designed in the current study. Based on flow distribution of the active rectification valve and driving energy provided by two MMPs, the actuator can output continuous and bidirectional displacement. By establishing a mathematical model of the actuating system, using simulation techniques, the change rule of hydraulic cylinder’s motion state caused by different driving signals are studied and analyzed. Test equipment platform is constructed in the laboratory to test the output characteristics and confirm the feasibility of the new concept. The experimental results indicate that the maximum flow rate can reach approximately 2.7 L·min−1, while the operating frequency is 180 Hz.


2021 ◽  
pp. 039156032110033
Author(s):  
Atef Fathi ◽  
Omar Mohamed ◽  
Osama Mahmoud ◽  
Gamal A Alsagheer ◽  
Ahmed M Reyad ◽  
...  

Background: Substitution urethroplasty using buccal mucosal grafts can be performed by several approaches including ventral onlay graft, dorsal onlay graft, or ventral urethrotomy with dorsal inlay graft. Our study aims to evaluate the surgical outcome of dorsolateral buccal mucosal graft for long segment anterior urethral stricture >6 cm in patients with Lichen sclerosus (LS). Methods: A retrospective study included patients who underwent repair for long segment anterior urethral stricture >6 cm due to LS between January 2013 and April 2019. All patients were followed-up at 3, 6, 9, and 12 months postoperatively and then yearly by clinical symptoms, uroflowmetry, and calculation of post-void residual urine volume. Retrograde urethrogram was requested for patients with voiding symptoms or decreased maximum flow rate. Stricture recurrence that required subsequent urethrotomy or urethroplasty was considered failure. The success rate and surgical complications were collected and analyzed. Results: Thirty patients were identified. The median age (range) was 39 (25–61) years and a median (range) stricture length was 8 (6–14) cm. Most of postoperative complications were of minor degree. The success rate at median follow-up of 15 (12–24) months was 86.5%. The median maximum flow rate increased significantly from 6 (2–11) ml/s preoperatively to 18 (range: 6–23) ml/s at the 6th month ( p value < 0.001). Conclusion: Dorsolateral buccal mucosal grafts urethroplasty for long anterior urethral stricture caused by LS has a high success rate and low risk of complications including stricture recurrence.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 500
Author(s):  
Jian Chen ◽  
Wenzhi Gao ◽  
Changhai Liu ◽  
Liangguo He ◽  
Yishan Zeng

This study proposes the improvement of the output performance of a resonant piezoelectric pump by adding proof masses to the free ends of the prongs of a U-shaped piezoelectric resonator. Simulation analyses show that the out-of-phase resonant frequency of the developed resonator can be tuned more efficiently within a more compact structure to the optimal operating frequency of the check valves by adjusting the thickness of the proof masses, which ensures that both the resonator and the check valves can operate at the best condition in a piezoelectric pump. A separable prototype piezoelectric pump composed of the proposed resonator and two diaphragm pumps was designed and fabricated with outline dimensions of 30 mm × 37 mm × 54 mm. Experimental results demonstrate remarkable improvements in the output performance and working efficiency of the piezoelectric pump. With the working fluid of liquid water and under a sinusoidal driving voltage of 298.5 Vpp, the miniature pump can achieve the maximum flow rate of 2258.9 mL/min with the highest volume efficiency of 77.1% and power consumption of 2.12 W under zero backpressure at 311/312 Hz, and the highest backpressure of 157.3 kPa under zero flow rate at 383 Hz.


1965 ◽  
Vol 87 (1) ◽  
pp. 134-141 ◽  
Author(s):  
F. J. Moody

A theoretical model is developed for predicting the maximum flow rate of a single component, two-phase mixture. It is based upon annular flow, uniform linear velocities of each phase, and equilibrium between liquid and vapor. Flow rate is maximized with respect to local slip ratio and static pressure for known stagnation conditions. Graphs are presented giving maximum steam/water flow rates for: local static pressures between 25 and 3,000 psia, with local qualities from 0.01 to 1.00; local stagnation pressures and enthalpies which cover the range of saturation states.


Author(s):  
Mohammad J. Izadi ◽  
Alireza Falahat

In this investigation an attempt is made to find the best hub to tip ratio, the maximum number of blades, and the best angle of attack of an axial fan with flat blades at a fixed rotational speed for a maximum mass flow rate in a steady and turbulent conditions. In this study the blade angles are varied from 30 to 70 degrees, the hub to tip ratio is varied from 0.2 to 0.4 and the number of blades are varied from 2 to 6 at a fixed hub rotational speed. The results show that, the maximum flow rate is achieved at a blade angle of attack of about 45 degrees for when the number of blades is set equal to 4 at most rotational velocities. The numerical results show that as the hub to tip ratio is decreased, the mass flow rate is increased. For a hub to tip ratio of 0.2, and an angle of attack around 45 degrees with 4 blades, a maximum mass flow rate is achieved.


Author(s):  
Yi Hou ◽  
Lipeng He ◽  
Zheng Zhang ◽  
Baojun Yu ◽  
Hong Jiang ◽  
...  

This paper focuses on a new structure in the valveless piezoelectric pump, which has a combination structure of the conical flow channel and two fishtail-shaped bluffbodies in the chamber of the pump. The fishtail-shaped bluffbody is inspired by the shape of the swimming fish to diminish the backflow and optimize the performance of the pump. The performance is studied by changing the shape and size of the inlet and outlet, the bluff bodies’ height and the space between two bluff bodies. The results show that the 3 mm × 3 mm square inlet, 3 mm diameter round outlet, 3 mm height of bluffbodies, 6.8 mm pitch of bluffbodies has a best performance in all 10 prototypes, which implements a maximum flow rate of 87.5 ml/min at 170 V 40 Hz with a noise of 42.6 dB. This study makes a preliminary investigation and theoretical explanation for the subsequent optimization of this structure, improved the performance of the valveless piezoelectric pump, broaden the thinking of the design for the bluffbody for better performance of the valveless piezoelectric pump.


1999 ◽  
Author(s):  
Ling-Sheng Jang ◽  
Christopher J. Morris ◽  
Nigel R. Sharma ◽  
Ron L. Bardell ◽  
Fred K. Forster

Abstract Micropumps designed for the flow-rate range of 100–1000μl/min have been developed by a number of research groups. However, little data is available regarding the ability of various designs to directly transport liquids containing particles such as cells, microspheres utilized for bead chemistry, or contaminants. In this study the ability of pumps with no-moving-parts valves (NMPV) to transport particles was investigated. The results showed that a NMPV micropump was able to directly pump suspensions of polystyrene microspheres from 3.1 to 20.3μm in diameter. The pump functioned without clogging at microsphere number densities as high as 9000 particles/μl of suspension, which corresponded to over 90,000 particles per second passing through the pump at a flow rate of 600μl/min. Performance with polystyrene microspheres was the same as pure water up to the point of cavitation. Microspheres manufactured with negative surface charge cavitated less readily that other microspheres studied that were manufactured without surface charge. However, cavitation did not appear to be a function of microsphere size, total surface area or number density. Thus pumping polystyrene microspheres was found to be more affected by surface effects than by size, surface area or number density within the range of parameters considered. In the case of charged microspheres, the maximum flow rate was reduced by 30% compared to pure water whereas for uncharged microspheres the maximum flow rate was reduced by approximately 80%.


Sign in / Sign up

Export Citation Format

Share Document