scholarly journals Facile Fabrication of a Self-Healing Temperature-Sensitive Sensor Based on Ionogels and Its Application in Detection Human Breath

Nanomaterials ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 343 ◽  
Author(s):  
Fengxia Wang ◽  
Shaohui Zhang ◽  
Yunlin Zhang ◽  
Qihang Lin ◽  
Yun Chen ◽  
...  

The biocompatible strechable ionogels were prepared by a facile solution-processed method. The ionogels showed outstanding stretchable and self-healing properties. The electrical property could revert to its original state after 4 s. The repaired ionogels could still bear stretching about 150%. Moreover, the ionogels exhibited high sensitivity and wide-detection range to temperature. The temperature-sensitive sensor could detect the human breath frequency and intensity, showing potential application in detecting disease.

2021 ◽  
Author(s):  
Zhanyu Jia ◽  
Guangyao Li ◽  
Juan Wang ◽  
shouhua Su ◽  
Jie Wen ◽  
...  

Conductivity, self-healing and moderate mechanical properties are necessary for multifunctional hydrogels which have great potential in health-monitor sensor application. However, the combination of electrical conductivity, self-healing and good mechanical properties...


Biosensors ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 208
Author(s):  
Hong Dinh Duong ◽  
Jong Il Rhee

In this study, ratiometric fluorescent glucose and lactate biosensors were developed using a ratiometric fluorescent oxygen-sensing membrane immobilized with glucose oxidase (GOD) or lactate oxidase (LOX). Herein, the ratiometric fluorescent oxygen-sensing membrane was fabricated with the ratio of two emission wavelengths of platinum meso-tetra (pentafluorophenyl) porphyrin (PtP) doped in polystyrene particles and coumarin 6 (C6) captured into silica particles. The operation mechanism of the sensing membranes was based on (i) the fluorescence quenching effect of the PtP dye by oxygen molecules, and (ii) the consumption of oxygen levels in the glucose or lactate oxidation reactions under the catalysis of GOD or LOX. The ratiometric fluorescent glucose-sensing membrane showed high sensitivity to glucose in the range of 0.1–2 mM, with a limit of detection (LOD) of 0.031 mM, whereas the ratiometric fluorescent lactate-sensing membrane showed the linear detection range of 0.1–0.8 mM, with an LOD of 0.06 mM. These sensing membranes also showed good selectivity, fast reversibility, and stability over long-term use. They were applied to detect glucose and lactate in artificial human serum, and they provided reliable measurement results.


2014 ◽  
Vol 1685 ◽  
Author(s):  
Ho Yeon Son ◽  
Yoon Sung Nam ◽  
Woo Soo Kim

ABSTRACTHere we introduce a facile method to fabricate a flexible piezoelectric sensor using one-dimensional (1-D) piezoelectric poly(vinylidene fluoride) (PVDF) nanofibers directly produced onto flexible printed electrodes by electro-spinning without an additional poling process. The flexible silver electrodes are fabricated on polyethylene terephthalate (PET) using silver nanowires by easy and cost-effective spraying deposition. The electrospun PVDF nanofibers have uniaxially aligned arrays on the electrodes by using a rotating collector. The fabricated PVDF piezoelectric sensors demonstrate the piezoelectric responses with repeated mechanical stimuli with good flexibility and high sensitivity. We expect that the facile fabrication of PVDF piezoelectric sensors on flexible printed electrodes can be usefully exploited to integrate the piezoelectric sensors into flexible and stretchable functional electronic devices.


2021 ◽  
Vol 368 (6) ◽  
Author(s):  
Liwen Zhang ◽  
Qingyu Lv ◽  
Yuling Zheng ◽  
Xuan Chen ◽  
Decong Kong ◽  
...  

ABSTRACT T-2 is a common mycotoxin contaminating cereal crops. Chronic consumption of food contaminated with T-2 toxin can lead to death, so simple and accurate detection methods in food and feed are necessary. In this paper, we establish a highly sensitive and accurate method for detecting T-2 toxin using AlphaLISA. The system consists of acceptor beads labeled with T-2-bovine serum albumin (BSA), streptavidin-labeled donor beads and biotinylated T-2 antibodies. T-2 in the sample matrix competes with T-2-BSA for antibodies. Adding biotinylated antibodies to the test well followed by T-2 and T-2-BSA acceptor beads yielded a detection range of 0.03–500 ng/mL. The half-maximal inhibitory concentration was 2.28 ng/mL and the coefficient of variation was <10%. In addition, this method had no cross-reaction with other related mycotoxins. This optimized method for extracting T-2 from food and feed samples achieved a recovery rate of approximately 90% in T-2 concentrations as low as 1 ng/mL, better than the performance of a commercial ELISA kit. This competitive AlphaLISA method offers high sensitivity, good specificity, good repeatability and simple operation for detecting T-2 toxin in food and feed.


2017 ◽  
Vol 95 (12) ◽  
pp. 1267-1272 ◽  
Author(s):  
Zhiyou Xiao ◽  
Anjiang Tang ◽  
Hongsheng Huang ◽  
Ze Wang

A simple and sensitive assay for Ag+ was developed with unmodified gold nanoparticles (AuNPs) by using dynamic light scattering techniques. Ag+ could induce the oligonucleotide (5′-ATC ACT ATA TCA TAT ACT CAT-3′) to change from a single-stranded structure to a double-stranded structure and desorb from the surface of AuNPs, which triggered the aggregation of AuNPs in the salt solution. The average hydrodynamic diameter of aggregated AuNPs could be detected by using dynamic light scattering techniques. Under the optimum conditions, the average hydrodynamic diameter of AuNPs is proportional to the concentration of Ag+ within the range of 13.3–100.0 nmol/L, with a detection limit of 3.2 nmol/L. The method is easy to operate and has low sample consumption, high sensitivity and selectivity.


2015 ◽  
Vol 645-646 ◽  
pp. 1298-1302
Author(s):  
Rui Zhao ◽  
Yong Zheng Wen ◽  
Wei Ma ◽  
Jian Cheng Yang ◽  
Xiao Mei Yu

In this paper, an aptasensor with high sensitivity and rapid response was developed for the detection of staphylococcus enterotoxin B (SEB) by using thiol-modified piezoresistive cantilever. Thiol-modified aptamers, acting as the functionalized sensing elements, were immobilized on the nanogold-coated surface of the sensing cantilever as agents for detecting SEB. By using the functionalized aptasensors, different concentrations of SEB were detected with a wide detection range of 6-100 ng/mL and a quick response in milk. The experimental results indicated that the cantilever-based aptasensors had sufficient sensitivity for the detection of SEB in real food commodities and might provide an economical platform for on-site detections of different toxicants with the advantages of portability, high sensitivity, and rapid response.


Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3881 ◽  
Author(s):  
Xiaogang Chen ◽  
Liang Fu ◽  
Qijing Lu ◽  
Xiang Wu ◽  
Shusen Xie

Liquid droplet and quasi-droplet whispering gallery mode (WGM) microcavities have been widely studied recently for the enhanced spatial overlap between the liquid and WGM field, especially in sensing applications. However, the fragile cavity structure and the evaporation of liquid limit its practical applications. Here, stable, packaged, quasi-droplet and droplet microcavities are proposed and fabricated for thermal sensing with high sensitivity. The sensitivity and electromagnetic field intensity distribution are analyzed by Mie theory, and a quantified definition of the quasi-droplet is presented for the first time to the best of our knowledge. By doping dye material directly into the liquid, lasing packaged droplet and quasi-droplet microcavity sensors with a high thermal sensitivity of up to 205.3 pm/°C are experimentally demonstrated. The high sensitivity, facile fabrication, and mechanically robust properties of the optofluidic, packaged droplet microresonator make it a promising candidate for future integrated photonic devices.


2020 ◽  
Vol 7 (12) ◽  
pp. 201500
Author(s):  
Sha Liu ◽  
Yong Li ◽  
Chao Yang ◽  
Liqiang Lu ◽  
Yulun Nie ◽  
...  

Arsenic contamination in groundwater is a supreme environmental problem, and levels of this toxic metalloid must be strictly monitored by a portable, sensitive and selective analytical device. Herein, a new system of smartphone-integrated paper sensors with Cu nanoclusters was established for the effective detection of As(III) in groundwater. For the integration system, the fluorescence emissive peak of Cu nanoclusters at 600 nm decreased gradually with increasing As(III) addition. Meanwhile, the fluorescence colour also changed from orange to colourless, and the detection limit was determined as 2.93 nM (0.22 ppb) in a wide detection range. The interfering ions also cannot influence the detection selectivity of As(III). Furthermore, the portable paper sensors based on Cu nanoclusters were fabricated for visual detection of As(III) in groundwater. The quantitative determination of As(III) in natural groundwater has also been accomplished with the aid of a common smartphone. Our work has provided a portable and on-site detection technique toward As(III) in groundwater with high sensitivity and selectivity.


Sign in / Sign up

Export Citation Format

Share Document