scholarly journals Hyperspectral Imaging from a Multipurpose Floating Platform to Estimate Chlorophyll-a Concentrations in Irrigation Pond Water

2020 ◽  
Vol 12 (13) ◽  
pp. 2070
Author(s):  
Geonwoo Kim ◽  
Insuck Baek ◽  
Matthew D. Stocker ◽  
Jaclyn E. Smith ◽  
Andrew L. Van Tassell ◽  
...  

This study provides detailed information about the use of a hyperspectral imaging system mounted on a motor-driven multipurpose floating platform (MFP) for water quality sensing and water sampling, including the spatial and spectral calibration for the camera, image acquisition and correction procedures. To evaluate chlorophyll-a concentrations in an irrigation pond, visible/near-infrared hyperspectral images of the water were acquired as the MFP traveled to ten water sampling locations along the length of the pond, and dimensionality reduction with correlation analysis was performed to relate the image data to the measured chlorophyll-a data. About 80,000 sample images were acquired by the line-scan method. Image processing was used to remove sun-glint areas present in the raw hyperspectral images before further analysis was conducted by principal component analysis (PCA) to extract three key wavelengths (662 nm, 702 nm, and 752 nm) for detecting chlorophyll-a in irrigation water. Spectral intensities at the key wavelengths were used as inputs to two near-infrared (NIR)-red models. The determination coefficients (R2) of the two models were found to be about 0.83 and 0.81. The results show that hyperspectral imagery from low heights can provide valuable information about water quality in a fresh water source.

2003 ◽  
Vol 11 (4) ◽  
pp. 269-281 ◽  
Author(s):  
Kurt C. Lawrence ◽  
William R. Windham ◽  
Bosoon Park ◽  
R. Jeff Buhr

A method and system for detecting faecal and ingesta contaminants on poultry carcasses were demonstrated. A visible/near infrared monochromator, which measured reflectance and principal component analysis were first used to identify key wavelengths from faecal and uncontaminated skin samples. Measurements at 434, 517, 565 and 628 nm were identified and used for evaluation with a hyperspectral imaging system. The hyperspectral imaging system, which was a line-scan (pushbroom) imaging system, consisted of a hyperspectral camera, fibre-optic line lights, a computer and frame grabber. The hyperspectral imaging camera consisted of a high-resolution charge coupled device (CCD) camera, a prism-grating-prism spectrograph, focusing lens, associated optical hardware and a motorised controller. The imaging system operated from about 400 to 900 nm. The hyperspectral imaging system was calibrated for wavelength, distance and percent reflectance and analysis of calibrated images at the key wavelengths indicated that single-wavelength images were inadequate for detecting contaminants. However, a ratio of images at two of the key wavelengths was able to identify faecal and ingesta contaminants. Specifically, the ratio of the 565-nm image divided by the 517-nm image produced good results. The ratio image was then further processed by masking the background and either enhancing the image contrast with a non-linear histogram stretch, or applying a faecal threshold. The results indicated that, for the limited sample population, more than 96% of the contaminants were detected. Thus, the hyperspectral imaging system was able to detect contaminants and showed feasibility, but was too slow for real-time on-line processing. Therefore, a multivariate system operating at 565 and 517 nm, which should be capable of operating at real-time on-line processing speed, should be used. Further research with such a system needs to be conducted.


2019 ◽  
Vol 11 (15) ◽  
pp. 1827 ◽  
Author(s):  
Paul V. Manley ◽  
Vasit Sagan ◽  
Felix B. Fritschi ◽  
Joel G. Burken

Explosives contaminate millions of hectares from various sources (partial detonations, improper storage, and release from production and transport) that can be life-threatening, e.g., landmines and unexploded ordnance. Exposure to and uptake of explosives can also negatively impact plant health, and these factors can be can be remotely sensed. Stress induction was remotely sensed via a whole-plant hyperspectral imaging system as two genotypes of Zea mays, a drought-susceptible hybrid and a drought-tolerant hybrid, and a forage Sorghum bicolor were grown in a greenhouse with one control group, one group maintained at 60% soil field capacity, and a third exposed to 250 mg kg−1 Royal Demolition Explosive (RDX). Green-Red Vegetation Index (GRVI), Photochemical Reflectance Index (PRI), Modified Red Edge Simple Ratio (MRESR), and Vogelmann Red Edge Index 1 (VREI1) were reduced due to presence of explosives. Principal component analyses of reflectance indices separated plants exposed to RDX from control and drought plants. Reflectance of Z. mays hybrids was increased from RDX in green and red wavelengths, while reduced in near-infrared wavelengths. Drought Z. mays reflectance was lower in green, red, and NIR regions. S. bicolor grown with RDX reflected more in green, red, and NIR wavelengths. The spectra and their derivatives will be beneficial for developing explosive-specific indices to accurately identify plants in contaminated soil. This study is the first to demonstrate potential to delineate subsurface explosives over large areas using remote sensing of vegetation with aerial-based hyperspectral systems.


Molecules ◽  
2020 ◽  
Vol 25 (7) ◽  
pp. 1651 ◽  
Author(s):  
Xiulin Bai ◽  
Qinlin Xiao ◽  
Lei Zhou ◽  
Yu Tang ◽  
Yong He

Sodium pyrosulfite is a browning inhibitor used for the storage of fresh-cut potato slices. Excessive use of sodium pyrosulfite can lead to sulfur dioxide residue, which is harmful for the human body. The sulfur dioxide residue on the surface of fresh-cut potato slices immersed in different concentrations of sodium pyrosulfite solution was classified by near-infrared hyperspectral imaging (NIR-HSI) system and portable near-infrared (NIR) spectrometer. Principal component analysis was used to analyze the object-wise spectra, and support vector machine (SVM) model was established. The classification accuracy of calibration set and prediction set were 98.75% and 95%, respectively. Savitzky–Golay algorithm was used to recognize the important wavelengths, and SVM model was established based on the recognized important wavelengths. The final classification accuracy was slightly less than that based on the full spectra. In addition, the pixel-wise spectra extracted from NIR-HSI system could realize the visualization of different samples, and intuitively reflect the differences among the samples. The results showed that it was feasible to classify the sulfur dioxide residue on the surface of fresh-cut potato slices immersed in different concentration of sodium pyrosulfite solution by NIR spectra. It provided an alternative method for the detection of sulfur dioxide residue on the surface of fresh-cut potato slices.


Author(s):  
Paul Williams ◽  
Terri-Lee Kammies ◽  
Pieter Gouws ◽  
Marena Manley

Near infrared hyperspectral imaging (NIR-HSI) and multivariate image analysis were used to distinguish between foodborne pathogenic bacteria, Bacillus cereus, Escherichia coli, Salmonella Enteritidis, Staphylococcus aureus and a non- pathogenic bacterium, Staphylococcus epidermidis. Hyperspectral images of bacteria, streaked out on Luria—Bertani agar, were acquired after 20 h, 40 h and 60 h growth at 37 °C using a SisuCHEMA hyperspectral pushbroom imaging system with a spectral range of 920–2514 nm. Three different pre-processing methods: standard normal variate (SNV), Savitzky—Golay (1stderivative, 2nd order polynomial, 15-point smoothing) and Savitzky—Golay (2nd derivative, 3rd order polynomial, 15-point smoothing) were evaluated. SNV provided the most distinct clustering in the principal component score plots and was thus used as the sole pre-processing method. Partial least squares discriminant analysis (PLS-DA) models were developed for each growth period and was tested on a second set of plates, to determine the effect the age of the colony has on classification accuracies. The highest overall prediction accuracies where test plates required the least amount of growth time, was found with models built after 60 h growth and tested on plates after 20 h growth. Predictions for bacteria differentiation within these models ranged from 83.1 % to 98.8 % correctly predicted pixels.


2011 ◽  
Vol 320 ◽  
pp. 569-573
Author(s):  
Jing Li ◽  
Long Xue ◽  
Mu Hua Liu ◽  
Xiao Wang ◽  
Chun Sheng Luo

A hyperspectral imaging system for detecting defect on navel orange was demonstrated. The hyperspectral imaging system, which was a line-scan imaging system, consisted of a hyperspectral camera, a halogen lighting unit, a computer and a translation stage. The imaging system operated from 400 to 1000nm. Principal component analysis (PCA) was performed using the hyperspectral images data (from 500 to 700nm); 2nd principal component (PC) image exhibited differential responses between normal and defect spots on the surface of navel orange. The combined use of the PC-2 images demonstrated the detection of defect spots with minimal false positives. Based on the PC-2 weighing coefficients, the dominant wavelengths were 528,529,530,673,674 and 675nm. This research demonstrated the potential of multispectral image for online applications for detection of defect on navel oranges.


2018 ◽  
Vol 8 (12) ◽  
pp. 2602 ◽  
Author(s):  
Laurence Schimleck ◽  
Joseph Dahlen ◽  
Seung-Chul Yoon ◽  
Kurt Lawrence ◽  
Paul Jones

Near-infrared (NIR) spectroscopy and NIR hyperspectral imaging (NIR-HSI) were compared for the rapid estimation of physical and mechanical properties of No. 2 visual grade 2 × 4 (38.1 mm by 88.9 mm) Douglas-fir structural lumber. In total, 390 lumber samples were acquired from four mills in North America and destructively tested through bending. From each piece of lumber, a 25-mm length block was cut to collect diffuse reflectance NIR spectra and hyperspectral images. Calibrations for the specific gravity (SG) of both the lumber (SGlumber) and 25-mm block (SGblock) and the lumber modulus of elasticity (MOE) and modulus of rupture (MOR) were created using partial least squares (PLS) regression and their performance checked with a prediction set. The strongest calibrations were based on NIR spectra; however, the NIR-HSI data provided stronger predictions for all properties. In terms of fit statistics, SGblock gave the best results, followed by SGlumber, MOE, and MOR. The NIR-HSI SGlumber, MOE, and MOR calibrations were used to predict these properties for each pixel across the transverse surface of the scanned samples, allowing SG, MOE, and MOR variation within and among rings to be observed.


Author(s):  
Qiao Jun ◽  
Michael Ngadi ◽  
Ning Wang ◽  
Aynur Gunenc ◽  
Mariana Monroy ◽  
...  

Pork quality is usually determined subjectively as PSE, PFN, RFN, RSE and DFD based on color, texture and exudation of the meat. In this study, a hyperspectral-imaging-based technique was developed to achieve rapid, accurate and objective assessment of pork quality. The principal component analysis (PCA) and stepwise operation methods were used to select feature waveband from the entire spectral wavelengths (430 to 980 nm). Then the feature waveband images were extracted at the selected feature wavebands from raw hyperspectral images, and the average reflectance (R) was calculated within the whole loin-eye area. Artificial neural network was used to classify these groups. Results showed that PCA analysis had a better performance than that of stepwise operation for feature waveband images selection. The 1st derivative data gave a better result than that of mean reflectance spectra data. The best classified result was 87.5% correction. The error frequency showed that RSE samples were easier to classify. The PFN and PSE samples were difficult to separate from each other.


Author(s):  
Laura M. DALE ◽  
André THEWIS ◽  
Ioan ROTAR ◽  
Juan A. FERNANDEZ PIERNA ◽  
Christelle BOUDRY ◽  
...  

Nowadays in agriculture, new analytical tools based on spectroscopic technologies are developed. Near Infrared Spectroscopy (NIRS) is a well known technology in the agricultural sector allowing the acquisition of chemical information from the samples with a large number of advantages, such as: easy to use tool, fast and simultaneous analysis of several components, non-polluting, noninvasive and non destructive technology, and possibility of online or field implementation. Recently, NIRS system was combined with imaging technologies creating the Near Infrared Hyperspectral Imaging system (NIR-HSI). This technology provides simultaneously spectral and spatial information from an object. The main differences between NIR-HSI and NIRS is that many spectra can be recorded simultaneously from a large area of an object with the former while with NIRS only one spectrum was recorded for analysis on a small area. In this work, both technologies are presented with special focus on the main spectrum and images analysis methods. Several qualitative and quantitative applications of NIRS and NIR-HSI in agricultural products are listed. Developments of NIRS and NIR-HSI will enhance progress in the field of agriculture by providing high quality and safe agricultural products, better plant and grain selection techniques or compound feed industry’s productivity among others.


Sign in / Sign up

Export Citation Format

Share Document