scholarly journals A Study on the Correlation between Change in the Geometrical Dimension of a Free-Falling Molten Glass Gob and Its Viscosity

Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 661
Author(s):  
Mazhar Hussain ◽  
Mattias O’Nils ◽  
Jan Lundgren ◽  
Irida Shallari

To produce flawless glass containers, continuous monitoring of the glass gob is required. It is essential to ensure production of molten glass gobs with the right shape, temperature, viscosity and weight. At present, manual monitoring is common practice in the glass container industry, which heavily depends on previous experience, operator knowledge and trial and error. This results in inconsistent measurements and consequently loss of production. In this article, a multi-camera based setup is used as a non-invasive real-time monitoring system. We have shown that under certain conditions, such as keeping the glass composition constant, it is possible to do in-line measurement of viscosity using sensor fusion to correlate the rate of geometrical change in the gob and its temperature. The correlation models presented in this article show that there is a strong correlation, i.e., 0.65, between our measurements and the projected viscosity.

Author(s):  
Evan Osborne

Does humanity progress primarily through leaders organizing and directing followers, or through trial and error by individuals free to chart their own path? For most of human history ruling classes had the capacity and the desire to tightly regiment society, to the general detriment of progress. But beginning in the 1500s, Europeans developed a series of arguments for simply leaving well enough alone. First in the form of the scientific method, then in the form of free expression, and finally in the form of the continuously, spontaneously reordered free market, people began to accept that progress is hard, and requires that an immense number of mistakes be tolerated so that we may learn from them. This book tells the story of the development of these three ideas, and for the first time tells of the mutual influence among them. It outlines the rise, and dramatic triumph, of each of these self-regulating systems, followed by a surprising rise in skepticism, especially in the economic context. Such skepticism in the 20th century was frequently costly and sometimes catastrophic. Under the right conditions, which are more frequent than generally believed, self-regulating systems in which participants organize themselves are superior. We should accept their turbulence in exchange for the immense progress they generate.


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 879
Author(s):  
Robert D. Crapnell ◽  
Ascanio Tridente ◽  
Craig E. Banks ◽  
Nina C. Dempsey-Hibbert

Lactate is widely measured in critically ill patients as a robust indicator of patient deterioration and response to treatment. Plasma concentrations represent a balance between lactate production and clearance. Analysis has typically been performed with the aim of detecting tissue hypoxia. However, there is a diverse range of processes unrelated to increased anaerobic metabolism that result in the accumulation of lactate, complicating clinical interpretation. Further, lactate levels can change rapidly over short spaces of time, and even subtle changes can reflect a profound change in the patient’s condition. Hence, there is a significant need for frequent lactate monitoring in critical care. Lactate monitoring is commonplace in sports performance monitoring, given the elevation of lactate during anaerobic exercise. The desire to continuously monitor lactate in athletes has led to the development of various technological approaches for non-invasive, continuous lactate measurements. This review aims firstly to reflect on the potential benefits of non-invasive continuous monitoring technology within the critical care setting. Secondly, we review the current devices used to measure lactate non-invasively outside of this setting and consider the challenges that must be overcome to allow for the translation of this technology into intensive care medicine. This review will be of interest to those developing continuous monitoring sensors, opening up a new field of research.


2018 ◽  
Vol 75 (5) ◽  
pp. 512-515 ◽  
Author(s):  
Sasa Hinic ◽  
Jelena Saric ◽  
Predrag Milojevic ◽  
Jelena Gavrilovic ◽  
Tijana Durmic ◽  
...  

Introduction. Myxoma is the most common primary benign heart tumor. The most frequent location is the left atrium, the chamber of the heart that receives oxygen- rich blood from the lungs. Myxomas usually develop in women, typically between the ages of 40 and 60. Symptoms may occur at any time, but most often they are asymptomatic or oligosymptomatic for a long period of time. Symptoms usually go along with body position, and are related to compression of the heart cavities, embolization and the appearance of general symptoms. The diagnosis of benign tumors of the heart is based on anamnesis, clinical features and findings of the tumor masses by use of non-invasive and invasive imaging methods. Extensive surgical resection of the myxoma is curative with minimal mortality. Long term clinical and echocardiographic follow-up is mandatory. Case report. We reported a case of a 62-year-old male, presented with 15 days of intermittent shortness of breath, dizziness and feeling of heart palpitations and subsequently diagnosed with right atrial myxoma based on transthoracic echocardiography . The patient was emergently operated in our hospital. Long-term followup did not reveal recurrence. Conclusion. Our case was an atypical localisation of right atrial myxoma. Whether the intracardiac mass is benign or malignant, early surgery is obligatory in order to prevent complications.


2021 ◽  
Vol 12 (2) ◽  
pp. 712-716
Author(s):  
Edsel Ing ◽  
Felix Tyndel ◽  
Joyce Tang ◽  
Thomas R. Marotta

A 67-year-old woman had delayed initial diagnosis of her right low flow carotid cavernous fistula (CCF) during the coronavirus disease (COVID-19) pandemic due to difficulty detecting ocular signs via online virtual examinations. Her right eye conjunctival erythema and proptosis with medial rectus enlargement on computed tomography scan was initially misdiagnosed as euthyroid thyroid-associated orbitopathy without lid retraction. She developed vision loss, and increasing episcleral venous congestion and CCF was suspected. Computed tomographic angiography did not show an obvious fistula. Digital subtraction angiography revealed the right-sided low flow CCF, which was fed from vessels from the contralateral side.


PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0256115
Author(s):  
Carlijn Lempersz ◽  
Lore Noben ◽  
Sally-Ann B. Clur ◽  
Edwin van den Heuvel ◽  
Zhouzhao Zhan ◽  
...  

Introduction A fetal anomaly scan in mid-pregnancy is performed, to check for the presence of congenital anomalies, including congenital heart disease (CHD). Unfortunately, 40% of CHD is still missed. The combined use of ultrasound and electrocardiography might boost detection rates. The electrical heart axis is one of the characteristics which can be deduced from an electrocardiogram (ECG). The aim of this study was to determine reference values for the electrical heart axis in healthy fetuses around 20 weeks of gestation. Material and methods Non-invasive fetal electrocardiography was performed subsequent to the fetal anomaly scan in pregnant women carrying a healthy singleton fetus between 18 and 24 weeks of gestation. Eight adhesive electrodes were applied on the maternal abdomen including one ground and one reference electrode, yielding six channels of bipolar electrophysiological measurements. After removal of interferences, a fetal vectorcardiogram was calculated and then corrected for fetal orientation. The orientation of the electrical heart axis was determined from this normalized fetal vectorcardiogram. Descriptive statistics were used on normalized cartesian coordinates to determine the average electrical heart axis in the frontal plane. Furthermore, 90% prediction intervals (PI) for abnormality were calculated. Results Of the 328 fetal ECGs performed, 281 were included in the analysis. The average electrical heart axis in the frontal plane was determined at 122.7° (90% PI: -25.6°; 270.9°). Discussion The average electrical heart axis of healthy fetuses around mid-gestation is oriented to the right, which is, due to the unique fetal circulation, in line with muscle distribution in the fetal heart.


2020 ◽  
Vol 16 (2) ◽  
pp. 86-91
Author(s):  
Md Harisul Hoque ◽  
SM Mustafa Zaman ◽  
Khurshid Ahmed ◽  
Sajal Krisna Banerjee ◽  
Md Faisal Ibne Kabir ◽  
...  

Pulmonary hypertension is a hemodynamic disorder defined by abnormally high pulmonary artery pressure that affects the arteries in your lungs and the right side of your heart. In this study, hepatic venous duplex will be done to diagnose and quantify the PH. So that Patients can avoid unnecessary invasive right heart catheterization. This practical demonstration is the key to enrich our experience and knowledge in the field of PH. Objectives of this study was to assess PH status by Hepatic venous Duplex (HVD) as well by right heart catheterization and to compare them. This study was conducted in the Department of Cardiology, BSMMU, Shahbagh, Dhaka extending from July 2018 to December 2019. Total 100 (One hundred) subjects were enrolled in this study. It was an Observational study and includes the subjects between 18 years to 45 years of age. Results of this study shows very close proximity to that of Right heart catheterization. Hemodynamic changes in Hepatic venous duplex study could be used as an alternative diagnostic tool for evaluating moderate to severe pulmonary hypertension. This method could counteract the weakness of the currently used diagnostic methods and improve the accuracy of assessing pulmonary hypertension when combined with other methods. University Heart Journal Vol. 16, No. 2, Jul 2020; 86-91


2000 ◽  
Author(s):  
Lin Ma ◽  
Erik K. Antonsson

Abstract A method for automated mask-layout and process synthesis for MEMS is presented. The synthesis problem is approached by use of a genetic algorithm. For a given desired device shape, and several fabrication process choices, this synthesis method will produce one or more mask-layouts and associated fabrication process sequences (which when used can generate shapes close to the desired one). Given complicated device shapes and wide range of fabrication process possibilities, the designer may encounter difficulty producing the right mask-layout and fabrication procedure by experience and trial and error. An automated synthesis tool like this will be helpful to the designer by increasing the efficiency and accuracy of the design of MEMS devices.


PEDIATRICS ◽  
1975 ◽  
Vol 55 (2) ◽  
pp. 232-235
Author(s):  
Gosta Rooth

Attention is called in this brief review article to the development and clinical uses of a new technique for monitoring blood oxygen tensions in newborn infants. This technique uses an electrode recently developed by Huch et al. in Germany to measure arterial oxygen tensions directly through the skin. This device allows for continuous monitoring with a non-invasive technique. The method is now in use in European hospitals. Clinical experiences are cited to document its usefulness.


Sign in / Sign up

Export Citation Format

Share Document