scholarly journals Countermovement Jump Analysis Using Different Portable Devices: Implications for Field Testing

Sports ◽  
2018 ◽  
Vol 6 (3) ◽  
pp. 91 ◽  
Author(s):  
Vincenzo Rago ◽  
João Brito ◽  
Pedro Figueiredo ◽  
Thiago Carvalho ◽  
Tiago Fernandes ◽  
...  

The aim of this study was to analyze the concurrent validity, test–retest reliability, and capacity to detect changes of four different portable devices used to measure a wide range of neuromuscular parameters derived from countermovement jump (CMJ). An accelerometric device (Myotest), a jump mat (Ergojump), an optical device (Optojump), and a smartphone app (MyJump) were simultaneously examined for concurrent validity against gold-standard measures (motion-capture system and a force platform). Twenty-two CMJ-derived variables were collected from 15 healthy male subjects (n = 60 CMJs). Contraction time (CT) and eccentric duration (EccD) measurements obtained from the Myotest were moderately to largely associated with and not different from force platform measurements (r = 0.31 to 0.64, ES = 0.11 to 0.18) and showed moderate test-retest reliability (intraclass correlation coefficient (ICC) = 0.92 to 0.97, coefficient of variation (CV) = 3.8 to 8.0%). Flight time (FT) and jump height (JH) from Ergojump, Optojump, and MyJump showed moderate to strong associations with gold-standard measurements (r = 0.57 to 0.98) and good test–retest reliability (ICC = 0.54 to 0.97, CV = 1.8 to 4.2). However, all portable devices underestimated JH (ES = 1.25 to 2.75). Independent of the instrument used, the analyzed CMJ variables showed good capacity to detect changes (standard error of measurement (SEM) < smallest worthwhile change (SWC)), with the exception of rate of force and rate of power development parameters, which showed marginal capacity (SEM > SWC). The Myotest is preferable to measure temporal parameters during ground contact, whereas Ergojump, Optojump, and MyJump devices may be preferable to measure FT and JH, with the Optojump being the most accurate.

2015 ◽  
Vol 45 (1) ◽  
pp. 19-26 ◽  
Author(s):  
Vincent Gouttebarge ◽  
Robin Wolfard ◽  
Nouschka Griek ◽  
Cornelis J. de Ruiter ◽  
Julitta S. Boschman ◽  
...  

Abstract The purpose of this study was to assess the reproducibility (test-retest reliability and agreement) and concurrent validity of the Myotest for measuring step frequency (SF) and ground contact time (GCT) in recreational runners. Based on a within-subjects design (test and retest), SF and GCT of 14 participants (11 males, 3 females) were measured at three different running speeds with the Myotest during two test sessions. SF and GCT were also assessed with a foot-mounted accelerometer (Gold Standard, previously validated by comparing to force plate data) during the first test session. Levels of test-retest reliability and concurrent validity were expressed with intraclass correlation coefficients (ICC), agreement with standard errors of measurement (SEM). For SF, test-retest reliability (ICC’s > 0.75) and agreement of the Myotest were considered as good at all running speeds. For GCT, test-retest reliability was found to be moderate at a running speed of 14 km/h and poor at speeds of 10 and 12 km/h (ICC < 0.50). Agreement of the Myotest for GCT at all three running speeds was considered not acceptable given the SEM’s calculated. Concurrent validity of the Myotest with the foot-mounted accelerometer (Gold Standard) at all three running speeds was found to be good for SF (ICC’s > 0.75) and moderate for GCT (0.50 < ICC’s < 0.75). The conclusion of our study is that estimates obtained with the Myotest are reproducible and valid for SF but not for GCT.


2021 ◽  
Vol 12 ◽  
Author(s):  
Wei Xia ◽  
William Ho Cheung Li ◽  
Tingna Liang ◽  
Yuanhui Luo ◽  
Laurie Long Kwan Ho ◽  
...  

Objectives: This study conducted a linguistic and psychometric evaluation of the Chinese Counseling Competencies Scale-Revised (CCS-R).Methods: The Chinese CCS-R was created from the original English version using a standard forward-backward translation process. The psychometric properties of the Chinese CCS-R were examined in a cohort of 208 counselors-in-training by two independent raters. Fifty-three counselors-in-training were asked to undergo another counseling performance evaluation for the test-retest. The confirmatory factor analysis (CFA) was conducted for the Chinese CCS-R, followed by internal consistency, test-retest reliability, inter-rater reliability, convergent validity, and concurrent validity.Results: The results of the CFA supported the factorial validity of the Chinese CCS-R, with adequate construct replicability. The scale had a McDonald's omega of 0.876, and intraclass correlation coefficients of 0.63 and 0.90 for test-retest reliability and inter-rater reliability, respectively. Significantly positive correlations were observed between the Chinese CCS-R score and scores of performance checklist (Pearson's γ = 0.781), indicating a large convergent validity, and knowledge on drug abuse (Pearson's γ = 0.833), indicating a moderate concurrent validity.Conclusion: The results support that the Chinese CCS-R is a valid and reliable measure of the counseling competencies.Practice implication: The CCS-R provides trainers with a reliable tool to evaluate counseling students' competencies and to facilitate discussions with trainees about their areas for growth.


2020 ◽  
pp. 153944922096107
Author(s):  
Ecem Karanfil ◽  
Yeliz Salcı ◽  
Ayla Fil-Balkan ◽  
Can Ebru Bekircan-Kurt ◽  
Sevim Erdem Özdamar ◽  
...  

Linguistic, reliable, and valid secondary efficacy measures are important in clinical settings and studies. The aim of the study is to report test–retest reliability and construct validity of Turkish version of Myasthenia Gravis-Activities of Daily Living Scale (MG-ADL-T) in Myasthenia Gravis (MG) patients. Fifty-two ocular and generalized individuals with MG, applying to rehabilitation center, were included in the study. MG-ADL-T, MG quality-of-life questionnaire (MG-QoL), MG composite (MGC), quantitative MG score (QMGS), and pulmonary function test were administered. Reliability was assessed with intraclass correlation coefficient (ICC) and Cronbach’s alpha. Spearman correlation test and receiver operating characteristic (ROC) analysis were performed for construct validity. MG-ADL-T had fair internal consistency (Cronbach’s α = .67), excellent test–retest reliability (ICC = 0.96) and moderate construct validity (MG-QoL, r = 0.59; QMGS, r = .58; MGC, r = .68). MG-ADL, a unique scale that evaluates activities of daily living (ADL), has good test–retest reliability and construct validity in Turkish MG patients.


Sensors ◽  
2019 ◽  
Vol 20 (1) ◽  
pp. 37 ◽  
Author(s):  
Christopher Buckley ◽  
M. Encarna Micó-Amigo ◽  
Michael Dunne-Willows ◽  
Alan Godfrey ◽  
Aodhán Hickey ◽  
...  

Asymmetry is a cardinal symptom of gait post-stroke that is targeted during rehabilitation. Technological developments have allowed accelerometers to be a feasible tool to provide digital gait variables. Many acceleration-derived variables are proposed to measure gait asymmetry. Despite a need for accurate calculation, no consensus exists for what is the most valid and reliable variable. Using an instrumented walkway (GaitRite) as the reference standard, this study compared the validity and reliability of multiple acceleration-derived asymmetry variables. Twenty-five post-stroke participants performed repeated walks over GaitRite whilst wearing a tri-axial accelerometer (Axivity AX3) on their lower back, on two occasions, one week apart. Harmonic ratio, autocorrelation, gait symmetry index, phase plots, acceleration, and jerk root mean square were calculated from the acceleration signals. Test–retest reliability was calculated, and concurrent validity was estimated by comparison with GaitRite. The strongest concurrent validity was obtained from step regularity from the vertical signal, which also recorded excellent test–retest reliability (Spearman’s rank correlation coefficients (rho) = 0.87 and Intraclass correlation coefficient (ICC21) = 0.98, respectively). Future research should test the responsiveness of this and other step asymmetry variables to quantify change during recovery and the effect of rehabilitative interventions for consideration as digital biomarkers to quantify gait asymmetry.


2020 ◽  
Vol 10 (11) ◽  
pp. 3805 ◽  
Author(s):  
Špela Bogataj ◽  
Maja Pajek ◽  
Slobodan Andrašić ◽  
Nebojša Trajković

This study aimed to examine the reliability, validity, and usefulness of the smartphone-based application, My Jump 2, against Optojump in recreationally active adults. Participants (18 women, 28.9 ± 5.6 years, and 26 men, 30.1 ± 10.6 years) completed squat jumps (SJ), counter-movement jumps (CMJ), and CMJ with arm swing (CMJAS) on Optojump and were simultaneously recorded using My Jump 2. To evaluate concurrent validity, jump height, calculated from flight time attained from each device, was compared for each jump type. Test-retest reliability was determined by replicating data analysis of My Jump 2 recordings on two occasions separated by two weeks. High test-retest reliability (Intraclass correlation coefficient (ICC) > 0.93) was observed for all measures in both male and female athletes. Very large correlations were observed between the My Jump 2 app and Optojump for SJ (r = 0.95, p = 0.001), CMJ (r = 0.98, p = 0.001), and CMJAS (r = 0.98, p = 0.001) in male athletes. Similar results were obtained for female recreational athletes for all jumps (r > 0.94, p = 0.001). The study results suggest that My Jump 2 is a valid, reliable, and useful tool for measuring vertical jump in recreationally active adults. Therefore, due to its simplicity and practicality, it can be used by practitioners, coaches, and recreationally-active adults to measure vertical jump performance with a simple test as SJ, CMJ, and CMJAS.


Sports ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. 117
Author(s):  
Mike Climstein ◽  
Jessica L. Alder ◽  
Alyce M. Brooker ◽  
Elissa J. Cartwright ◽  
Kevin Kemp-Smith ◽  
...  

Background: Usage of wrist-worn activity monitors has rapidly increased in recent years, and these devices are being used by both fitness enthusiasts and in clinical populations. We, therefore, assessed the test–retest reliability of the Polar Vantage M (PVM) watch when measuring heart rate (HR) during various treadmill exercise intensities. Methods: HR was measured every 30 s (simultaneous electrocardiography (ECG) and PVM). Test–retest reliability was determined using an intraclass correlation coefficient (ICC) with 95% confidence intervals (CIs). Standard error of measurement (SEM) and smallest real difference (SRD) were used to determine measurement variability. Results: A total of 29 participants completed the trials. ICC values for PVM during stages 1, 2 and 5 demonstrated good to excellent test–retest reliability (0.78, 0.78 and 0.92; 95% CI (0.54–0.90, 0.54–0.9, 0.79–0.97)). For PVM during stages 0 (rest), 3 and 4, the ICC values indicated poor to good reliability (0.42, 0.68 and 0.58; 95% CI (−0.27–0.73, 0.32–0.85, 0.14–0.80)). Conclusion: This study identified that the test–retest reliability of the PVM was comparable at low and high exercise intensities; however, it revealed a poor to good test–retest reliability at moderate intensities. The PVM should not be used in a clinical setting where monitoring of an accurate HR is crucial to the patients’ safety.


2010 ◽  
Vol 7 (5) ◽  
pp. 671-676 ◽  
Author(s):  
Suzie Mudge ◽  
Denise Taylor ◽  
Oliver Chang ◽  
Rosita Wong

Background:Activity Monitors give an objective measure of usual walking performance. This study aimed to examine the test-retest reliability of the StepWatch Activity Monitor outputs (mean steps/day; peak activity index; sustained activity indices of 1, 5, 20, 30, 60 minutes; steps at high, medium, and low stepping rates).Methods:Thirty healthy adults age 18 to 49 years wore the StepWatch for 2 3-day periods at least 1 week apart.Results:The intraclass correlation coefficients of the StepWatch outputs ranged from 0.44 to 0.91 over 3 days. The coefficient of variation ranged from 3.0% to 51.3% over the monitoring periods, with higher variation shown for shorter monitoring periods. The most reliable 5 outputs had 95% limits of agreement between 3-day periods that were less than 40%. These were mean steps/day (±39.1%), highest step rate in 1 (±17.3%) and 5 (±37.4%) minutes, peak activity index (±25.6%), and percentage of inactive time (±9.52%).Conclusions:Mean steps/day, highest step rate in 1 and 5 minutes, peak activity index, and percentage of inactive time have good test-retest reliability over a 3-day monitoring period, with lower reliability shown by the other StepWatch outputs. Monitoring over 1 or 2 days is less reliable.


2014 ◽  
Vol 19 (2) ◽  
pp. 93-96 ◽  
Author(s):  
Carlo Jurth ◽  
Benno Rehberg ◽  
Falk von Dincklage

BACKGROUND: The endogenous modulation of pain can be assessed through conditioned pain modulation (CPM), which can be quantified using subjective pain ratings or nociceptive flexion reflexes. However, to date, the test-retest reliability has only been investigated for subjective pain ratings.OBJECTIVE: To compare the test-retest reliability of CPM-induced changes, measured using subjective pain ratings and nociceptive flexion reflexes, to provide a reliable scoring parameter for future studies.METHOD: A total of 40 healthy volunteers each received painful electrical stimuli to the sural nerve to elicit nociceptive flexion reflexes. Reflex sizes and subjective pain ratings were recorded before and during the immersion of the contralateral hand in hot water to induce CPM as well as innocuous water as control. Measurements were repeated in a retest 28 days later.RESULTS: Intraclass correlation coefficients showed good test-retest reliabilities of CPM during the hot water stimulus for both scoring parameters. Subjective pain ratings also correlated between test and retest during the control stimulus.CONCLUSIONS: Subjective pain ratings and nociceptive flexion reflexes show comparable test-retest reliabilities, but they reflect different components of CPM. While subjective pain ratings appear to incorporate cognitive influences to a larger degree, reflex responses appear to reflect spinal nociception more purely.


2016 ◽  
Vol 96 (12) ◽  
pp. 1955-1964 ◽  
Author(s):  
Cathy C. Harro ◽  
Alicia Marquis ◽  
Natasha Piper ◽  
Chris Burdis

Abstract Background Complex movement and balance impairments in people with Parkinson disease (PD) contribute to high fall risk. Comprehensive balance assessment is warranted to identify intrinsic fall risk factors and direct interventions. Objective The purpose of this study was to examine the psychometric properties of 3 balance measures of a force platform (FP) system in people with PD. Methods Forty-two community-dwelling individuals with idiopathic PD completed the testing protocol. Test-retest reliability was assessed for the Limits of Stability Test (LOS), Motor Control Test (MCT), and Sensory Organization Test (SOT). Intraclass correlation coefficients (ICC [2,1]) were calculated to determine test-retest reliability and minimal detectable change. Validity was assessed by comparing the FP measures with criterion gait and balance measures using Pearson product moment correlations. Multiple regression analyses examined the contribution of PD characteristics to FP measures. Results All primary FP variables demonstrated excellent test-retest reliability (ICC=.78–.92). The SOT and LOS demonstrated fair to good correlations with criterion measures, whereas the MCT had fair correlations to balance measures only. Both SOT composite equilibrium and MCT average latency were moderately associated with disease severity. Limitations This study's sample had a relatively small number of participants with a positive fall history, which may limit the generalizability of the findings. Conclusions This study's findings provide support that FP measures are reliable and valid tests of balance impairment in people with PD. Disease severity was significantly associated with SOT and MCT measures, perhaps reflecting that these tests are meaningful indicators of decline in postural control with disease progression. Force platform measures may provide valuable quantitative information about underlying balance impairments in people with PD to guide therapeutic interventions for fall risk reduction.


2013 ◽  
Vol 48 (3) ◽  
pp. 331-336 ◽  
Author(s):  
Rebecca Shultz ◽  
Scott C. Anderson ◽  
Gordon O. Matheson ◽  
Brandon Marcello ◽  
Thor Besier

Context: The Functional Movement Screen (FMS) is a popular test to evaluate the degree of painful, dysfunctional, and asymmetric movement patterns. Despite great interest in the FMS, test-retest reliability data have not been published. Objective: To assess the test-retest and interrater reliability of the FMS and to compare the scoring by 1 rater during a live session and the same session on video. Design: Cross-sectional study. Setting: Human performance laboratory in the sports medicine center. Patients or Other Participants: A total of 21 female (age = 19.6 ± 1.5 years, height = 1.7 ± 0.1 m, mass = 64.4 ± 5.1 kg) and 18 male (age = 19.7 ± 1.0 years, height = 1.9 ± 0.1 m, mass = 80.1 ± 9.9 kg) National Collegiate Athletic Association Division IA varsity athletes volunteered. Intervention(s): Each athlete was tested and retested 1 week later by the same rater who also scored the athlete's first session from a video recording. Five other raters scored the video from the first session. Main Outcome Measure(s): The Krippendorff α (K α) was used to assess the interrater reliability, whereas intraclass correlation coefficients (ICCs) were used to assess the test-retest reliability and reliability of live-versus-video scoring. Results: Good reliability was found for the test-retest (ICC = 0.6), and excellent reliability was found for the live-versus-video sessions (ICC = 0.92). Poor reliability was found for the interrater reliability (K α = .38). Conclusions: The good test-retest and high live-versus-video session reliability show that the FMS is a usable tool within 1 rater. However, the low interrater K α values suggest that the FMS within the limits of generalization should not be used indiscriminately to detect deficiencies that place the athlete at greater risk for injury. The FMS interrater reliability may be improved with better training for the rater.