scholarly journals Impact of Compressor Drive System Efficiency on Air Source Heat Pump Performance for Heating Hot Water

2020 ◽  
Vol 12 (24) ◽  
pp. 10521
Author(s):  
Mariusz Szreder ◽  
Marek Miara

A standard Polish household with a central heating system powered by a solid fuel furnace was chosen as a case study. The modular Air Source Heat Pump (ASHP) was used to heat the hot water outside the heating season. In this article comparative studies of the impact of the compressor drive system used on the energy efficiency of the heat pump have been carried out in operating conditions. The ASHP heating capacity and coefficient of performance (COP) were determined for the outside air temperature in the range from 7 to 22 °C by heating the water in the tank to a temperature above 50 °C. For the case of a fixed speed compressor, average heating capacity in the range 2.7−3.1 kW and COP values in the range 3.2−4.6 depending on the evaporator supply air temperature were obtained. Similarly, for the inverter compressor, the average heating capacity in the range of 2.7−5.1 kW was obtained for the frequency in the range of 30–90 Hz and COP in the range 4.2−5.7, respectively. On cool days, the average heating capacity of the heat pump decreases by 12%. For the simultaneous operation of two compressors with comparable heating capacity, lower COP values were obtained by 20%.

Author(s):  
Suola Shao ◽  
Huan Zhang ◽  
Shijun You ◽  
Yaran Wang

Abstract In response to the triple crisis of energy–environment–economy (3Es), the air-source heat pump (ASHP) system is considered to be one of the most feasible candidates to upgrade the traditional high emission heating solutions. In this paper, a novel thermal storage refrigerant-heated panel (RHP) is proposed for the ASHP heating system. Experiments were conducted in a climate chamber to test the heating and defrosting performance of the system, the thermal performance of the RHP, the system energy efficiency, and the system economic feasibility. The results show that the heat flux of the RHP is as high as 625.5 W/m2 at a condensation temperature of 40 °C and an outdoor air temperature of −7 °C. Meanwhile, the system is demonstrated to be reliable and competitive with efficient thermal stability in heating conditions and comfortable indoor thermal in defrosting conditions. The coefficient of performance (COP) ranges from 2.2 to 4.0 when the outdoor air temperature changes from −12 °C to 7 °C in the tests. Meanwhile, the initial capital cost and the total annual cost of the proposed system are 430 USD and 203.1 USD, respectively, which is competitive in the distracted heating systems.


2013 ◽  
Vol 671-674 ◽  
pp. 2141-2144 ◽  
Author(s):  
Qiang Wang ◽  
Feng Zhen Liu ◽  
Li Jun Hou ◽  
Jian Hua Gao

A solar assisted air source heat pump unit is designed. The mathematical model of the unit is established and two hybrid operating conditions of the system are simulated. The simulative studying results shows that in winter the solar assisted air source heat pump unit can make full use of solar energy and the coefficient of performance (COP) of air source heat pump can be improved. In summer the cooling heat of air source heat pump could be recovered to improve the stability of solar hot water collector and the COP of the air source heat pump unit is greatly improved. The performance of solar assisted air source heat pump unit is better than that of with no solar assisted air source heat pump.


Energies ◽  
2019 ◽  
Vol 12 (22) ◽  
pp. 4313 ◽  
Author(s):  
Boahen ◽  
Choi

The use of cascade heat pumps for hot water generation has gained much attention in recent times. The big question that has attracted much research interest is how to enhance the performance and energy saving potential of these cascade heat pumps. This study therefore proposed a new cycle to enhance performance of the cascade heat pump by adopting an auxiliary heat exchanger (AHX) in desuperheater, heater and parallel positions at the low stage (LS) side. The new cascade cycle with AHX in desuperheater position was found to have better performance than that with AHX at heater and parallel positions. Compared to the conventional cycle, heating capacity and coefficient of performance (COP) of the new cascade cycle with AHX in desuperheater position increased up to 7.4% and 14.9% respectively.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2642 ◽  
Author(s):  
Yi Zhang ◽  
Guanmin Zhang ◽  
Aiqun Zhang ◽  
Yinhan Jin ◽  
Ruirui Ru ◽  
...  

Frost layer on the outdoor air heat exchanger surface in an air-source heat pump (ASHP) can decrease the system coefficient of performance (COP). Although the common defrosting and anti-frosting methods can improve the COP, the periodic defrosting not only reduces the system energy efficiency but also deteriorates the indoor environment. To solve these problems, it is necessary to clearly understand the frosting phenomenon and to achieve the system frost-free operation. This paper focused firstly on the analyses of frosting pathways and frosting maps. Followed by summarizing the characteristics of frost-free technologies. And then the performances of two types of frost-free ASHP (FFASHP) systems were reviewed, and the exergy and economic analysis of a FFASHP heating system were carried out. Finally, the existing problems related to the FFASHP technologies were proposed. Results show that the existing frosting maps need to be further improved. The FFASHP systems can not only achieve continuous frost-free operation but reduce operating cost. And the total COP of the FFASHP heating system is approximately 30–64% higher than that of the conventional ASHP system under the same frosting conditions. However, the investment cost of the FFASHP system increases, and its reliability also needs further field test in a wider frosting environment. In the future, combined with a new frosting map, the control strategy for the FFASHP system should be optimized.


Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 479
Author(s):  
Ignacio Paniagua ◽  
Ángel Álvaro ◽  
Javier Martín ◽  
Celina Fernández ◽  
Rafael Carlier

Although CO 2 as refrigerant is well known for having the lowest global warming potential (GWP), and commercial domestic heat pump water heater systems exist, its long expected wide spread use has not fully unfolded. Indeed, CO 2 poses some technological difficulties with respect to conventional refrigerants, but currently, these difficulties have been largely overcome. Numerous studies show that CO 2 heat pump water heaters can improve the coefficient of performance (COP) of conventional ones in the given conditions. In this study, the performances of transcritical CO 2 and R410A heat pump water heaters were compared for an integrated nearly zero-energy building (NZEB) application. The thermodynamic cycle of two commercial systems were modelled integrating experimental data, and these models were then used to analyse both heat pumps receiving and producing hot water at equal temperatures, operating at the same ambient temperature. Within the range of operation of the system, it is unclear which would achieve the better COP, as it depends critically on the conditions of operation, which in turn depend on the ambient conditions and especially on the actual use of the water. Technology changes on each side of the line of equal performance conditions of operation (EPOC), a useful design tool developed in the study. The transcritical CO 2 is more sensitive to operating conditions, and thus offers greater flexibility to the designer, as it allows improving performance by optimising the global system design.


2017 ◽  
Vol 8 (3) ◽  
pp. 404-411 ◽  
Author(s):  
Yuguo Wu ◽  
Yake Jiang ◽  
Bo Gao ◽  
Zhigang Liu ◽  
Jing Liu

Abstract Water reuse and desalination systems are energy intensive processes, and their increasing use is leading energy consumption within water systems to be an increasingly important issue. Shower wastewater contains large amounts of heat, so there is an opportunity to recover energy from shower water to offset energy consumption elsewhere in water systems. This paper found ways to increase the output of hot water and lower the energy consumption by establishing a thermodynamic model of an instantaneous wastewater source heat pump. The system proved to be very effective, the heating COP (coefficient of performance) can reach 3.3 even in the winter. Under the conditions of limited heat transfer area, reducing the suction pressure of a compressor is a more feasible way to increase the hot water output to meet the needs of users rather than increasing the discharge pressure. Besides, increasing the heat transfer area of the evaporator is a more effective option. When the heat transfer area of evaporator varies from 0.5 to 1.0 square meters, a notable change is that the heating COP increases from 3.283 to 3.936. The heating COP in a system with a recuperator can reach 5.672, almost double that compared to the original systems.


2014 ◽  
Vol 541-542 ◽  
pp. 942-948
Author(s):  
Xian Peng Sun ◽  
Zhi Rong Zou ◽  
Yue Zhang

Based on the finite-time thermodynamic theory, an operation optimization, of water source heat pump in the combined solar with a dual heat source heat pump which is applied in a greenhouse heating system, is made. According to the ε-NTU method and entropy theory, heat exchange and balance equations are obtained. The function relationship between COP and the indoor temperature Tn, the ambient temperature Ta, low temperature heat source inlet temperature Tie and high temperature heat source inlet temperature Tic is also obtained. By means of programming, the impact of parameters on the COP and the way of regulating this water source heat pump system are presented in this article. The results show that: when a separate water source heat pump is running, by adjusting the hot water temperature and the match status of each indoor heating system, the energy-saving operation can be realized.


Energies ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 5476
Author(s):  
Sławomir Zator ◽  
Waldemar Skomudek

This article presents a case study of a single-family house, whose current energy source is electricity only. Nine years ago, the heat source for the heating system and domestic hot water was an oil boiler, which was changed to an air–water heat pump. Four years ago, when Poland formed the basis of the prosumer market, the first photovoltaic system was established. It was expanded in the following years. In this work are presented the impact of using a heat accumulator on the coefficient of performance of the heat pump, the self-consumption of energy from the photovoltaic system, and the cost of purchasing energy. Comparative calculations were made, with the demand-side management (DSM) active on work days, and on free days (weekends and public holidays) it was not. Attention was paid to the self-consumption factor depending on the algorithms used in an energy meter. The prosumer market in Poland was also described. The calculations described the house as having an annual energy self-consumption from photovoltaic about 6% higher than average values obtained in buildings with heat pumps. Simultaneously, due to energy storage in heat and the load shifting in the multi-zone tariff, the cost of purchasing energy was 47% lower than in a single-zone tariff (without heat storage and load shifting).


2019 ◽  
Vol 1 (1) ◽  
pp. 154-163 ◽  
Author(s):  
Konstantinos Ninikas ◽  
Nicholas Hytiris ◽  
Rohinton Emmanuel ◽  
Bjorn Aaen

In this short communication, we demonstrate that the performance of a typical air source heat pump (ASHP), exploiting a relatively stable air temperature within a subway environment, is high, even during the peak heating months. After a nine-month operational run, the coefficient of performance is demonstrated to be 3.5. The design and installation difficulties are stated together with the lessons learnt following this trial. The actual energy and carbon savings are discussed.


2015 ◽  
Vol 797 ◽  
pp. 185-191
Author(s):  
Arkadiusz Gużda ◽  
Norbert Szmolke

The article compares two means for domestic hot water production (DHW) for a detached house that is using gas boiler with a closed combustion chamber and air source heat pump water heater (ASHPWH). An analysis of domestic hot water production using an air source heat pump was made taking into account coefficient of performance listed according to the new BS EN 16147 standard. The analysis of outlay related to the investment and operating costs was also performed. Ultimately, the more profitable choice for domestic hot water production was made.