scholarly journals A Sensitivity Analysis for Thermal Performance of Building Envelope Design Parameters

2021 ◽  
Vol 13 (24) ◽  
pp. 14018
Author(s):  
Sara Elhadad ◽  
Zoltan Orban

Sensitivity analysis is crucial in building energy assessments. It is used to determine the major variables influencing building thermal performance, using both observational research and energy simulation models. This study investigates the most influential envelope design parameters on the thermal performance of a typical residential building in Budapest, Hungary. Sensitivity analysis is used in conjunction with the IDA-Indoor and Climate Energy (IDA-ICE 4.8) simulation tool to assess the effects of 33 envelope design parameters for energy consumption and carbon dioxide concentrations. The input parameters include thickness, materials, density, specific heat and thermal conductivity of the basement, exterior floor, interior floor, exterior wall, interior wall, roof, ground slab, glazing type, and infiltration rate. The results show that exterior floor materials have the biggest impact on annual delivered energy for heating and cooling, whereas the density of all structural elements and thickness of the basement, exterior floors, interior floors, and walls have minimal effects on energy consumption. It is also shown that the impact of all investigated parameters is not sensitive to the carbon dioxide concentration in the building. The authors consider that the findings of the paper assist designers to assess the performance of existing buildings and more efficiently generating alternative solutions in the energetic retrofitting of existing and energy design of new residential buildings.

Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2538
Author(s):  
Praveen K. Cheekatamarla

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO2 per kWh electricity.


2020 ◽  
pp. 174425912090624
Author(s):  
Shima Moolavi Sanzighi ◽  
Farzaneh Soflaei ◽  
Mehdi Shokouhian

This article focuses on evaluating thermal performance of different types of residential buildings in Mediterranean climate (Csa) of Iran. The aim is to identify the main design parameters in nine research cases, selected from three distinct periods of history with different architectural styles, and evaluating thermal performance of these buildings. To that end, a library study was carried out to identify the most influential passive design strategies and to highlight their impact on thermal comfort and energy efficiency of residential buildings. A field survey was conducted to determine the most common types of average-income houses in Csa climate of Gorgan, Iran, with a historical overview from 19th century to present. Nine buildings were selected to study from three different period of times including the years from 1850 to 1925, 1925 to 1979 and 1979 to present. A three-dimensional numerical model was developed to assess the impact of four main design parameters including orientation, geometrical properties, openings and materials on indoor thermal comfort for each case, using Design Builder commercial software package. The correlation between these design variables and thermal comfort was presented; the results reveal that the contemporary residential buildings are not designed as efficient as traditional houses in this area, in terms of passive energy saving techniques.


2020 ◽  
Vol 12 (3) ◽  
pp. 1091 ◽  
Author(s):  
Waqas Ahmed Mahar ◽  
Griet Verbeeck ◽  
Sigrid Reiter ◽  
Shady Attia

Buildings are significant drivers of greenhouse gas emissions and energy consumption. Improving the thermal comfort of occupants in free-running buildings and avoiding active and fossil fuel-based systems is the main challenge in many cities worldwide. However, the impacts of passive design measures on thermal comfort in cold semi-arid regions are seldom studied. With the rapid urbanization and the widespread use of personalised heating and cooling systems, there is a need to inform building designers and city authorities about passive design measures that can achieve nearly optimal conditions. Therefore, in this study, a global sensitivity analysis of the impact of passive design parameters on adaptive comfort in cold semi-arid climates was conducted. A representative residential building was simulated and calibrated in Quetta, Pakistan, to identify key design parameters for optimal thermal comfort. The results list and rank a set of passive design recommendations that can be used widely in similar climates. The results show that among the investigated 21 design variables, the insulation type of roof is the most influential design variable. Overall, the sensitivity analysis yielded new quantitative and qualitative knowledge about the passive design of buildings with personalised heating systems, but the used sensitivity analysis has some limitations. Finally, this study provides evidence-based and informed design recommendations that can serve architects and homeowners to integrate passive design measures at the earliest conceptual design phases in cold semi-arid climates.


2019 ◽  
Vol 4 (11) ◽  
pp. 81
Author(s):  
Lobna Elgheriani ◽  
Brian Cody

Nowadays, high-rise buildings are developing very fast to cater to the increase in demand in major urban cities. This phenomenon has contributed to several environmental problems in both construction and operation. High-rise buildings design parameters seem to lack contextual environmental consideration. Evaluating the impact of such design parameters is a practical approach to enhance the overall energy and thermal performance. Existing research gaps are distinguished based on this review. Future research directions are also proposed through a methodological scheme to investigate comparatively, the effects of different geometric factors on both thermal and energy performance, specifically in the high-rise residential buildings with consideration to different climatic regions. Keywords: Energy Performance; Thermal Performance; High-rise Buildings; High-rise Residential BuildingseISSN: 2398-4287 © 2019. The Authors. Published for AMER ABRA cE-Bs by e-International Publishing House, Ltd., UK. This is an open access article under the CC BYNC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer–review under responsibility of AMER (Association of Malaysian Environment-Behaviour Researchers), ABRA (Association of Behavioural Researchers on Asians) and cE-Bs (Centre for Environment-Behaviour Studies), Faculty of Architecture, Planning & Surveying, Universiti Teknologi MARA, Malaysia.DOI: https://doi.org/10.21834/e-bpj.v4i11.1717


2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


Arsitektura ◽  
2018 ◽  
Vol 16 (1) ◽  
pp. 129
Author(s):  
Sri Yuliani ◽  
Wiwik Setyaningsih

<p class="Abstract"><em>The surface temperature of the building material may release a heat load in the micro-environment. The largest building envelope receives the heat load of solar radiation is the roof. The strategic roof position at the top of the building has the opportunity to radiate heat received into the environment. Heat emissions lead to rising temperatures, so it is necessary to lower the temperature in micro-environment. When the heat of the building is not lowered will lead to an increase in the urban heat island (UHI). The objective of the study was to find the relationship between the thermal performance of the roof of the building and the energy efficiency in the high-rise building, in order to establish efficient thermal comfort. The research method uses experimental way in real model which is in Surakarta City, as humid tropical climate area. The result of the study is a comparison of the heat performance of three roofing materials which would later recommend the criteria of energy efficient roof for high buildings.</em><em></em></p>


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7590
Author(s):  
Adam Kula ◽  
Albert Smalcerz ◽  
Maciej Sajkowski ◽  
Zygmunt Kamiński

There are many papers concerning the consumption of energy in different buildings. Most describe residential buildings, with only a few about office- or public service buildings. Few articles showcase the use of energy consumption in specific rooms of a building, directed in different geographical directions. On the other hand, many publications present methods, such as machine learning or AI, for building energy management and prediction of its consumption. These methods have limitations and represent a certain level of uncertainty. In order to compare energy consumption of different rooms, the measurements of particular building-room parameters were collected and analyzed. The obtained results showcase the effect of room location, regarding geographical directions, for the consumption of energy for heating. For south-exposed rooms, due to sun radiation, it is possible to switch heating off completely, and even overheating of 3 °C above the 22 °C temperature set point occurs. The impact of the sun radiation for rooms with a window directed east or west reached about 1 °C and lasts for a few hours before noon for the east, and until late afternoon for the west.


2021 ◽  
Vol 14 (1) ◽  
pp. 65
Author(s):  
Muhammad Usman ◽  
Georg Frey

The comprehensive approach for a building envelope design involves building performance simulations, which are time-consuming and require knowledge of complicated processes. In addition, climate variation makes the selection of these parameters more complex. The paper aims to establish guidelines for determining a single-family household’s unique optimal passive design in various climate zones worldwide. For this purpose, a bi-objective optimization is performed for twenty-four locations in twenty climates by coupling TRNSYS and a non-dominated sorting genetic algorithm (NSGA-III) using the Python program. The optimization process generates Pareto fronts of thermal load and investment cost to identify the optimum design options for the insulation level of the envelope, window aperture for passive cooling, window-to-wall ratio (WWR), shading fraction, radiation-based shading control, and building orientation. The goal is to find a feasible trade-off between thermal energy demand and the cost of thermal insulation. This is achieved using multi-criteria decision making (MCDM) through criteria importance using intercriteria correlation (CRITIC) and the technique for order preference by similarity to ideal solution (TOPSIS). The results demonstrate that an optimal envelope design remarkably improves the thermal load compared to the base case of previous envelope design practices. However, the weather conditions strongly influence the design parameters. The research findings set a benchmark for energy-efficient household envelopes in the investigated climates. The optimal solution sets also provide a criterion for selecting the ranges of envelope design parameters according to the space heating and cooling demands of the climate zone.


Author(s):  
Kaleb Pattawi ◽  
Prateek Munankarmi ◽  
Michael Blonsky ◽  
Jeff Maguire ◽  
Sivasathya Pradha Balamurugan ◽  
...  

Abstract Residential buildings, accounting for 37% of the total electricity consumption in the United States, are suitable for demand response (DR) programs to support effective and economical operation of the power system. A home energy management system (HEMS) enables residential buildings to participate in such programs, but it is also important for HEMS to account for occupant preferences to ensure occupant satisfaction. For example, people who prefer a higher thermal comfort level are likely to consume more energy. In this study, we used foresee™, a HEMS developed by the National Renewable Energy Lab (NREL), to perform a sensitivity analysis of occupant preferences with the following objectives: minimize utility cost, minimize carbon footprint, and maximize thermal comfort. To incorporate the preferences into the HEMS, the SMARTER method was used to derive a set of weighting factors for each objective. We performed week-long building energy simulations using a model of a home in Fort Collins, Colorado, where there is mandatory time-of-use electricity rate structure. The foresee™ HEMS was used to control the home with six different sets of occupant preferences. The study shows that occupant preferences can have a significant impact on energy consumption and is important to consider when modeling residential buildings. Results show that the HEMS could achieve energy reduction ranging from 3% to 21%, cost savings ranging from 5% to 24%, and carbon emission reduction ranging from 3% to 21%, while also maintaining a low thermal discomfort level ranging from 0.78 K-hour to 6.47 K-hour in a one-week period during winter. These outcomes quantify the impact of varying occupant preferences and will be useful in controlling the electrical grid and developing HEMS solutions.


Sign in / Sign up

Export Citation Format

Share Document