scholarly journals The Effect of Glaze Coating on Wear Resistance of Some Acrylic Denture Teeth: An In Vitro Study

2021 ◽  
Vol 13 (2) ◽  
pp. 47-51
Author(s):  
Samaneh Abbasi ◽  
Soodabe Ebrahimi ◽  
Arash Shisheian ◽  
Maryam Farhadian

Background: Acrylic resin teeth wear resistance has an important role in the denture longevity. This study aimed to clarify the effect of glaze coating on wear resistance of three types of artificial acrylic teeth. Methods: In this in vitro study, the wear resistance rate of three of acrylic denture teeth (GENIUS, STON and CLASSIC) was compared with Ivoclar teeth (n=25/group). The wear resistance was measured by estimating the weight loss in pre and post removing glaze coating, following 5000 cycles in the chewing simulator device. Data analysis was made using paired t test, one-way ANOVA and Tukey’s post hoc test. Results: ANOVA test showed that there was no significant difference between the mean amount of wear of GENIUS, CLASSIC, STON and IVOCLAR teeth in the first stage (P <0.061), but this difference was significant (P <0.001) in the second stage. The result of Tukey post hoc test showed that wear rates of GENIUS were significantly lower than other groups (P<0.001). Comparison between the mean wear rates of each dental group at the first and second stages showed a significant difference between average teeth wear resistance of CLASSIC, STON and IVOCLAR in the first and second stages (P <0.001). Conclusions: In conclusion, the teeth wear resistance of STON and CLASSIC were similar to IVOCLAR. Also, after removing the glaze coating, the teeth wear resistance decreased in all groups but was not statistically significant for group GENIUS.

Author(s):  
Praneetha D Rani ◽  
Vijaya Hegde

Introduction: Fluoride toothpastes are a major reason for the decline in dental caries globally. For fluoride toothpaste to be effective, an adequate amount of Total Soluble Fluoride (TSF) must be available in the toothpastes. Aim: To determine and compare the Total Fluoride (TF), TSF and pH among various toothpaste brands. Materials and Methods: An in-vitro study was conducted during October 2019 on 20 toothpaste samples, which belonged to four groups namely, herbal toothpastes group, nonherbal toothpastes group, medicated toothpastes group and kids toothpastes group. Analysis of the samples was done at the Department of Environmental Engineering Laboratory, National Institute of Technology, Surathkal, Karnataka, India. The TF and the TSF concentration was determined using fluoride ion electrode. The pH was determined using pH meter. Statistical analysis was performed using Statistical Package for Social Sciences (SPSS version 19.0). Analysis of variance (ANOVA) was used by Tukey’s post-hoc test to determine the difference between groups. The level of significance was kept at 0.05. Results: The results showed that there was a significant difference between the toothpaste types for mean TF concentration (p=0.004). The post-hoc test showed that there was a significant difference between herbal and nonherbal toothpastes (p=0.041) where the mean TF concentration for nonherbal toothpastes was 1095.20 ppm when compared to herbal toothpastes was 704.40 ppm. The results showed that there was a siginificant difference between the toothpaste types for Mean TSF concentration (p<0.003). There was a significant difference between medicated and kids toothpastes (p=0.024) where the mean total soluble fluoride concentration for medicated toothpastes was 938.60 ppm when compared to the kids toothpastes was 521.20 ppm. Conclusion: The present study showed that pH of all the toothpastes were either neutral or alkaline and the TSF concentration was less when compared to TF concentrations.


2021 ◽  
Vol 11 (4) ◽  
pp. 306-312
Author(s):  
Dalia M. Abouelmagd ◽  
Hanan K. Abouelseoud

Objectives: This study aimed to compare the microshear bond strength (µSBS) of self-adhesive flowable composite and conventional bonded flowable composite to sound and caries affected dentin. Materials and Methods: In this in vitro study, a total of freshly extracted 40 human molar teeth were used. The occlusal surface was sectioned to expose dentin for µSBS test. The teeth were randomly divided into 2 groups according to the type of flowable composite used into two groups (n=20): group A: self- adhesive flowable composite (Vertise flow), group B: Filtek Z350-XT flowable composite and one-step self-etch adhesive Adper Easy One. A plastic cylindrical mold was used to construct resin composite cylinders (0.8mm diameter x 1mm length) on the sound and caries affected exposed dentin and filled with flowable composite restorative materials according to manufacturer’s instructions. The samples were then immersed in distilled water at 37°C for 24 hours, and underwent µSBS test at a crosshead speed of 0.5 mm/min. Data were analyzed using Student's t-test to compare between the two materials as well as to compare between sound and caries affected dentin. Results: The mean values of µSBS of Filtek Z-350XT to sound and caries affected were 26.6 and 26.7 MPa respectively. The mean µSBS of Vertise Flow to sound and affected were 13.2 and 17.9 MPa respectively. With sound dentin FiltekZ-350XT showed statistically significant higher µSBS than Vertise flow. With caries affected dentin, there was no statistically significant difference between the two materials. There was no statistically significant difference between µSBS of sound and caries affected dentin within each material. The significance level was set at P ≤ 0.05. Conclusions: Within the limitations of this study, the conventional flowable composite yielded the highest µSBS to sound dentin. There was no statistical significant difference in µSBS of self-adhesive and conventional flowable to caries affected dentin. Key words: Composite Resins; Dentin; microshear.


Author(s):  
Amit Baban Pokharkar ◽  
Umesh Gopal Palekar ◽  
Veena Saraf ◽  
Deepak Machindra Vikhe ◽  
Shefali Sevakram Bhiwapurkar ◽  
...  

Introduction: The conventional impression procedure plays a major role in prosthodontics inspite of advancement in intra- oral scanning devices and 3D imaging procedures. Dimensional accuracy and surface detail reproduction are important for recording an impression. Aim: The study evaluated and compared the dimensional accuracy and surface detail reproduction of Polyvinyl Siloxane (PVS) and vinyl siloxane ether impression materials when used under dry and moist conditions. Materials and Methods: An in-vitro study was conducted in the Department of Prosthodontics, Rural Dental College, Pravara Institute of Medical Sciences, Loni, Ahmednagar, Maharashtra, India, for a period of two years from October 2018 to September 2020. A total of 60 impressions were made with PVS (Group A) and vinyl siloxane ether (Group B) under dry (A1, B1) and moist (A2, B2) conditions of stainless steel dies which had lines engraved on superior surface of the die. Using a Harloc’s Tool maker’s microscope, dimensional accuracy was measured by comparing the width of line Y in each impression. Surface detail reproduction was evaluated by American Dental Association (ADA) specification no. 19 where it stated continuous replication of at least any two lines out of the three lines inscribed on the die. Data analysis processing was performed in the SYSTAT version 12 (made by Crane’s software, Bangalore). Student’s unpaired t-test and Chi-square test were performed to determine statistical difference between PVS and vinyl siloxane ether where the level of significance was set at 5% and 1%. Results: The mean dimensional change and SD values for PVS under dry condition ranged from 21.93±2.46 to 22.40±2.89 (in mm). The mean dimensional change and SD values for PVS under moist condition ranged from 22.87±3.20 to 23.33±3.42. The mean dimensional change and SD values for vinyl siloxane ether under dry condition ranged from 21.93±3.61 to 24.73±5.20. The mean dimensional change and SD values for vinyl siloxane ether under moist condition ranged from 21.93±4.48 to 22.87±4.15. No statistical difference was found under dry and moist conditions within 2 hours and after 24 hours for both the materials. Conclusion: The study revealed no significant difference between dimensional accuracy and surface detail reproduction for PVS and vinyl siloxane ether. Both the materials can reproduce the details under dry and moist conditions satisfactorily and remained dimensionally stable till 24 hours after impression making.


2020 ◽  
Vol 8 (11) ◽  
pp. 569-575
Author(s):  
Pooja Yadav ◽  
◽  
Ashish Jain ◽  
Rahul Rao ◽  
Harshil Patel ◽  
...  

Aims: This is an vitro study compares and evaluates the effect of magnification tools on frequency and extent of iatrogenic damage to approximal tooth surface during conservative Class II cavity preparations. Methods and Material: 30 Typodont teeth were divided into 3 groups 10 typodont teeth in each group and were mounted on Phantom head. Teeth were prepared for class II (MO) cavity on 36 with conservative design using airotor with naked eye, loupes and microscope and iatrogenic damage was assessed on tooth no 35. Assessment of iatrogenic damage of all the groups was done by profilometer test. Statistical analysis used:Statistical analysis was done using one-way analysis of variance (ANOVA). Post-hoc pair-wise comparisons were done using Dunnetts test. Results: Results revealed that tooth preparation was better under microscopes and loupes with statistical significant difference for samples with loupes and microscope on comparison with naked eye. Study also expressed the difficulty faced during tooth preparation with microscope and loupes for the first time. Conclusions: Magnifying tools helps in better vision and less iatrogenic damage while preparing the tooth for restoration.


Author(s):  
Mohammadreza Malekipour ◽  
Zahra Norouzi ◽  
Sahar Shahlaei

Objectives: The purpose was to investigate the effect of casein phosphopeptide-amorphous calcium phosphate fluoride (CPP-ACPF) paste, Remin Pro paste, and 0.05% sodium fluoride (NaF) mouthwash on teeth discoloration after home bleaching. Materials and Methods: In this in-vitro study, 48 intact and unstained human incisors were divided into four groups (n=12): control (Group 1), CPP-ACPF paste (Group 2), Remin Pro paste (Group 3), and 0.05% NaF mouthwash (Group 4). The specimens were bleached using 20% carbamide peroxide gel for 21 days and were subjected to pH cycling and surface treatment with remineralizing agents for one month. The color of the specimens was determined according to the CIELAB color space at baseline, after bleaching, and after surface treatment. Data were analyzed using one-way analysis of variance (ANOVA), post-hoc least significant difference (LSD) test, and one-sample t-test (P=0.05). Results: ANOVA showed a significant difference in the mean ΔE of the four groups after surface treatment (P<0.05). Post-hoc LSD test showed a significant difference between the mean ΔE of the control group and those of the treatment groups (P<0.05) with no significant difference between the treatment groups, except for Remin Pro. The mean ΔE and ΔL of the Remin Pro group showed less change than those of the CPP-ACPF and NaF groups, indicating that Remin Pro has the lowest potential for post-bleaching tooth discoloration. Conclusion: CPP-ACPF paste, Remin Pro paste, and 0.05% NaF mouthwash cause noticeable teeth discoloration immediately after bleaching. Remin Pro has less effect on tooth color than the other two products.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2014 ◽  
Vol 60 (5) ◽  
pp. 200-203
Author(s):  
Andreea Borş ◽  
Cristina Molnar-Varlam ◽  
Melinda Székely

Abstract Objective: The aim of this in vitro study was to evaluate the influence of erosive conditions on the wear resistance of aesthetic direct restorative materials. Methods: Six dental filling materials were tested: two composites (Filtek Z550 and X-tra fil), two compomers (Dyract Extra and Twinky Star) and two glass ionomers (Ketac Molar and Fuji II LC). Twenty disks (10mm×2mm) of each material were prepared (n=120) and kept in artificial saliva at 37˚C for 24 hours. Specimens were cycled in acidic soft drink (Coca-Cola) 5×/day, for 5’, over 30 days. Initial surface roughness ISR (Ra-μm) and final surface roughness FSR were measured using a profilometer. The wear rate was calculated as difference of final minus the initial roughness (ΔSR=FSR-ISR). For statistical analysis t-test and one-way ANOVA test were used by GraphPad Prism version 5.03 statistical software. The level of significance was set at p<0.05. Results: The erosive wear rates (mean±SD, μm) after exposure to acidic beverage were: 0.30±0.03 (Ketac Molar), 0.28±0.04 (Fuji II LC), 0.27±0.00 (Filtek Z550), 0.23±0.01 (X-tra fil), 0.20±0.00 (Twinky Star) and 0.14±0.01 Dyract Extra, respectively. There were significant differences between the tested materials (p<0.05). Conclusions: Dental filling materials had different behaviour under the same erosive condition, however all investigated aesthetic restorative materials showed surface degradation. These findings suggest that erosive wear resistance of tooth coloured restoratives could influence their longevity in intraoral acidic conditions. Acknowledgements: The study was supported by the Internal Research Grant no. 5/30.01.2013 of the University of Medicine and Pharmacy of Tirgu Mureş.


2019 ◽  
Vol 2 (2) ◽  
Author(s):  
Ahmed Alagwany ◽  
Diab Fatoh ◽  
Mohamed Abbas ◽  
Mohamed A. Helal ◽  
Ihab I. Mahmoud

2020 ◽  
Vol 11 (2) ◽  
pp. 160-166
Author(s):  
Mohammad Javad Moghaddas ◽  
Horieh Moosavi ◽  
Sara Yaghoubirad ◽  
Nasim Chiniforush

Introduction: The purpose of this study was to compare the effect of the bioactive glass, the glass ionomer, and the Erbium YAG laser as liners on the remineralization of the affected dentin. Methods: The present study was conducted on 64 healthy extracted human molars divided into 4 groups, 1 control group and 3 experimental groups. After artificially inducing dentinal caries lesions, each of the experimental groups was applied to the cavity floor and then restored with a composite. The samples were stored after thermocycling in an incubator for two months. Finally, the hardness of the cavity floor was measured at 3 depths of 20, 50 and 100 μm by the Vickers microhardness tester. The dentin conditions underneath the liners were also evaluated with FESEM. Statistical analysis was performed by two-way ANOVA and the post-hoc Games-Howell test (P<0.05). Results: Among the groups, the lowest microhardness value was in the control group (P<0.05) except at a depth of 100 μm; therefore, there was no significant difference between the control group and the bioactive glass (P>0.05). The laser group had the highest microhardness value, which was significantly different from the control group (P<0.05). There was a significant difference between the laser and bioactive glass (P<0.05), except at a depth of 20 μm. The laser and glass ionomer had only a significant difference at a depth of 100 μm (P<0.05). The microhardness value induced by glass ionomer was higher than bioactive glass, which in no depth was significant (P>0.05). Partial dentinal tubule occlusion was observed with FESEM in each of the experimental groups as compared to the control group. Conclusion: The microhardness values were higher in all groups than in the control group. The laser might be more successful in remineralization than the other ones.


Author(s):  
Royan Diana ◽  
Hedijanti Joenoes ◽  
Ariadna A Djais

Objective: This study aimed to compare the effect of Curcuma xanthrorrhiza ethanol extract to the viability of Streptococcus mutans and Aggregatibacter  actinomycetemcomitans using single- and dual-species biofilm at different phases of formation.Methods: Biofilm models were incubated for 4, 12, and 24 hrs, then exposed to the extract at a concentration of 0.525%.Results: The viability of the single-species S. mutans biofilm was low (p<0.05), and no significant difference (p>0.05) was found between singlespeciesA. actinomycetemcomitans and dual-species biofilm.Conclusions: Curcuma xanthorrhiza ethanol extract is more effective for decreasing the viability of single-species S. mutans biofilm.