Flow/Heat Transfer Analysis and Shape Optimization of a Heat Exchanger with Internally Finned Tube

2005 ◽  
Vol 29 (4) ◽  
pp. 460-468 ◽  
Author(s):  
Juhee Lee ◽  
Sanghwan Lee ◽  
Hyo-Jae Lim ◽  
Kyoungwoo Park
2018 ◽  
Vol 6 (3) ◽  
pp. 1-12
Author(s):  
Kamil Abdul Hussien

Abstract-The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively.


2010 ◽  
Vol 31 (3) ◽  
pp. 87-104 ◽  
Author(s):  
Piotr Wais

Fluid flow consideration in fin-tube heat exchanger optimizationThe optimization of finned tube heat exchanger is presented focusing on different fluid velocities and the consideration of aerodynamic configuration of the fin. It is reasonable to expect an influence of fin profile on the fluid streamline direction. In the cross-flow heat exchanger, the air streams are not heated and cooled evenly. The fin and tube geometry affects the flow direction and influences temperature changes. The heat transfer conditions are modified by changing the distribution of fluid mass flow. The fin profile impact also depends on the air velocity value. Three-dimensional models are developed to find heat transfer characteristics between a finned tube and the air for different air velocities and fin shapes. Mass flow weighted average temperatures of air volume flow rate are calculated in the outlet section and compared for different fin/tube shapes in order to optimize heat transfer between the fin material and air during the air flow in the cross flow heat exchanger.


Author(s):  
Manikandan Mohan ◽  
K.C. Udaiyakumar

Voluminous cram has been carried out in this project which is intended to improve the conjugate heat-transfer performance of a heat-exchanger. In this study, CFD method is effectively used to predict the effect of Protruded Fins in heat exchanger, which protrudes inside the tube in addition to the shell side. CFD analysis on Protruded Finned Heat Exchanger (PFHE) is carried out with three different fin configurations like rectangular, triangular and parabolic fins. The baseline model of counter flow shell-tube heat-exchanger is considered with standard dimensions and analyzed initially without fins. Later the numbers of fins are increased to optimize the fin position and counts. The shape of the fins is then modified to find an optimized model with a higher heat-transfer coefficient. Hence, the present conjugate heat-transfer and flow analysis focus on optimizing the number of fins for a heat-exchanger with counter flow along with the shape optimization of fins. The computational values are measured with the net heat exchange between the cold and hot-fluids in terms of temperature difference. Also, the area averaged surface heat transfer co-efficient (h) of the heat exchanger with different fin configurations are plotted and compared.


Author(s):  
Farah Abdulzahra Taher ◽  
Zena Khalefa Kadhim

The aim of this study to improve the performance of heat exchanger by using the medium integral fins on the cross flow heat exchanger practically, so, two the heat exchangers from copper were manufactures with eight passes for comparison under different boundary conditions. The water flow rate flow inner the tubes with (2, 3, 4, 5, 6) L/min with inlet temperatures (50, 60, 70) oC, as for the air flow rate were passed outer the tubes by speeds (1, 1.7, 2.3) m/sec. The results show that the medium integral finned tube gives more improvement the heat transfer than the smooth tube about 203.97% and 205.1% was enhancement factor. Motivation: The aim is improvement the heat transfer coefficient for cross flow heat exchanger by using medium integral finned tube. Study the effect of various water stream rate, air speed and inlet water temperature on heat transfer coefficient for them, Finding the cases which enhanced heat transfer for various ranges of air and water as well as inlet temperatures and the speed at the entrance. Develop the empirical correlations for (Nua) of smooth and medium integral finned tubes as function of (Pra) and (Rea).


2018 ◽  
Vol 2018 ◽  
pp. 1-18
Author(s):  
Muhammad Ishaq ◽  
Khalid Saifullah Syed ◽  
Zafar Iqbal ◽  
Ahmad Hassan

A DG-FEM based numerical investigation has been performed to explore the influence of the various geometric configurations on the thermal performance of the conjugate heat transfer analysis in the triangular finned double pipe heat exchanger. The computed results dictate that Nusselt number in general rises with values of the conductivity ratio of solid and fluid, for the specific configuration parameters considered here. However, the performance of these parameters shows strong influence on the conductivity ratio. Consequently, these parameters must be selected in consideration of the thermal resistance, for better design of heat exchanger.