Noise Cancellation in ECG Signals with an Unbiased Adaptive Filter

Author(s):  
Yunfeng Wu ◽  
Rangaraj M. Rangayyan

The electrocardiographic (ECG) signal is a transthoracic manifestation of the electrical activity of the heart and is widely used in clinical applications. This chapter describes an unbiased linear adaptive filter (ULAF) to attenuate high-frequency random noise present in ECG signals. The ULAF does not contain a bias in its summation unit and the filter coefficients are normalized. During the adaptation process, the normalized coefficients are updated with the steepest-descent algorithm to achieve efficient filtering of noisy ECG signals. A total of 16 ECG signals were tested in the adaptive filtering experiments with the ULAF, the least-mean-square (LMS), and the recursive-least-squares (RLS) adaptive filters. The filtering performance was quantified in terms of the root-mean-squared error (RMSE), normalized correlation coefficient (NCC), and filtered noise entropy (FNE). A template derived from each ECG signal was used as the reference to compute the measures of filtering performance. The results indicated that the ULAF was able to provide noise-free ECG signals with an average RMSE of 0.0287, which was lower than the second-best RMSE obtained with the LMS filter. With respect to waveform fidelity, the ULAF provided the highest average NCC (0.9964) among the three filters studied. In addition, the ULAF effectively removed more noise, measured by FNE, in comparison with the LMS and RLS filters in most of the ECG signals tested. The issues of adaptive filter setting for noise reduction in ECG signals are discussed at the end of this chapter.

Author(s):  
Yunfeng Wu ◽  
Rangaraj M. Rangayyan

The authors propose an unbiased linear adaptive filter (ULAF) to eliminate high-frequency random noise in electrocardiographic (ECG) signals. The ULAF does not contain a bias in its summation unit, and the filter coefficients are normalized. During the adaptation process, the normalized coefficients are updated with the steepest-descent algorithm in order to achieve efficient filtering of noisy ECG signals. The authors tested the ULAF with ECG signals recorded from 16 subjects, and compared the performance of the ULAF with that of the least-mean-square (LMS) and recursive-least-squares (RLS) adaptive filters. The filtering performance was quantified in terms of the root-mean-squared error (RMSE), normalized correlation coefficient (NCC), and filtered noise entropy (FNE). A template derived from each ECG signal was used as the reference to compute the measures of filtering performance. The results indicated that the ULAF was able to provided noise-free ECG signals with an average RMSE of 0.0287, which was lower than the second best RMSE (0.0365) obtained with the LMS filter. With respect to waveform fidelity, the proposed ULAF provided the highest average NCC (0.9964) among the three filters studied. In addition, the ULAF effectively removed more noise measured by FNE versus the LMS and RLS filters in most of the ECG signals tested.


2021 ◽  
Vol 18 (3) ◽  
pp. 291-302
Author(s):  
George Karraz

Power line interference is the main noise source that contaminates Electrocardiogram (ECG) signals and measurements. In recent years, adaptive filters with different approaches have been investigated to eliminate power line interference in ECG waveforms. Adaptive line enhancement filter is a special type of adaptive filter that, unlike other adaptive filters, does not require a reference signal and has potential application in ECG signal filtering. In this paper, a selflearning filter based on an adaptive line enhancement (ALE) filter is proposed to remove power line interference in ECG signals. We simulate the adaptive filter in MATLwith a noisy ECG signal and analyze the performance of algorithms in terms of signal-to-noise ratio (SNR) improvement. The proposed algorithm is validated with Physikalisch-Technische Bundesanstalt (PTB) ECG signals database. Additive white gaussian noise is added to the raw ECG signal. Influential parameters on the ALE filter performance such as filter delay, the convergence factor, and the filter length are analyzed and discussed.


Sign Least Mean Square (SLMS) adaptive filter can adapt dynamically based on corresponding filter output. One of the major applications of adaptive filter is Noise cancellation. In real time applications like medical computing, speed of the process developing hardware is essential hence the hardware realization of SLMS adaptive filter using Xilinx System generator is proposed in this work. The propose architecture aims to reduce convergence rate, path delay and increasing speed. In this work (i) Modified architecture is designed for a 8-tap SLMS adaptive filter and (ii) multiplier less structure for Modified DLMS Filter. The designed architecture tested for ECG signal. The functionality of the algorithm is verified in MATLAB with various ECG data from the MIT-BIH database as input. Both LMS and SLMS are designed, simulated, synthesized and implemented in Virtex-5 FPGA using Xilnix ISE 14.3 . The result shows 5% decrease in total real time router completion and also decrease in the number of adders and subtractors, the maximum combinational path delay has been reduced by 48.84% in Systolic Sign LMS Filter when compared to LMS Filter.


Author(s):  
IMTEYAZ AHMAD ◽  
F. ANSARI ◽  
U.K. DEY

Background: The electrocardiogram(ECG) has the considerable diagnostic significance, and applications of ECG monitoring are diverse and in wide use. Noises that commonly disturb the basic electrocardiogram are power line interference(PLI), instrumentation noise, external electromagnetic field interference, noise due to random body movements and respiration movements. These noises can be classified according to their frequency content. It is essential to reduce these disturbances in ECG signal to improve accuracy and reliability. The bandwidth of the noise overlaps that of wanted signals, so that simple filtering cannot sufficiently enhance the signal to noise ratio. It is difficult to apply filters with fixed filter co-efficients to reduce these noise. Adaptive filter technique is required to overcome this problem as the filter coefficients can be varied to track the dynamic variations of the signals. Adaptive filter based on the least mean square (LMS) algorithm and recursive least squares (RLS) algorithm are applied to noisy ECG to reduce 50 Hz power line noise and motion artifact noise. Method: ECG signal is taken from physionet database. A ECG signal (without noise) was mixed with constant 0.1 mVp-p 50 Hz interference and motion artifact noise processed with Adaptive filter based on the least mean square (LMS) algorithm and recursive least squares (RLS) algorithm. Simulation results are also shown. Performance of filters are analyzed based on SNR and MSE.


2021 ◽  
Vol 34 (1) ◽  
pp. 133-140
Author(s):  
Teimour Tajdari

This study investigates the ability of recursive least squares (RLS) and least mean square (LMS) adaptive filtering algorithms to predict and quickly track unknown systems. Tracking unknown system behavior is important if there are other parallel systems that must follow exactly the same behavior at the same time. The adaptive algorithm can correct the filter coefficients according to changes in unknown system parameters to minimize errors between the filter output and the system output for the same input signal. The RLS and LMS algorithms were designed and then examined separately, giving them a similar input signal that was given to the unknown system. The difference between the system output signal and the adaptive filter output signal showed the performance of each filter when identifying an unknown system. The two adaptive filters were able to track the behavior of the system, but each showed certain advantages over the other. The RLS algorithm had the advantage of faster convergence and fewer steady-state errors than the LMS algorithm, but the LMS algorithm had the advantage of less computational complexity.


2020 ◽  
Author(s):  
Lu Shen ◽  
Yuriy Zakharov ◽  
Benjamin Henson ◽  
Nils Morozs ◽  
Paul Mitchell

<div>Abstract:</div><div><br></div><div>To enable full-duplex (FD) in underwater acoustic (UWA) systems, a high level of self-interference (SI) cancellation (SIC) is required. For digital SIC, adaptive filters are used. In time-invariant channels, the SI can be effectively cancelled by classical recursive least-square (RLS) adaptive filters, such as the sliding-window RLS (SRLS) or exponential-window RLS, but their SIC performance degrades in time-varying channels, e.g., in channels with a moving sea surface. Their performance can be improved by delaying the filter inputs. This delay, however, makes the mean squared error (MSE) unsuitable for measuring the SIC performance. In this paper, we propose a new evaluation metric, the SIC factor (SICF), which gives better indication of the SIC performance compared to MSE. The SICF can be used in experiments and in real FD systems. A new SRLS adaptive filter based on parabolic approximation of the channel variation in time, named SRLS-P, is also proposed. The SIC performance of the SRLS-P adaptive filter and classical RLS algorithms (with and without the delay) is evaluated by simulation and in lake experiments. The results show that the SRLS-P adaptive filter significantly improves the SIC performance, compared to the classical RLS adaptive filters.</div>


2017 ◽  
Vol 2017 ◽  
pp. 1-11
Author(s):  
Yongzhi Li ◽  
Cheng Tao ◽  
Yapeng Li ◽  
Liu Liu ◽  
Tao Zhou

The performance of media-based modulation (MBM) systems, where additional information can be conveyed by the indices of the channel states created by RF mirrors, over time-selective channels is investigated. By transforming the MBM system model into a traditional MIMO system model, we first propose a reduced complexity sphere decoder algorithm. Then two channel tracking algorithms, which are based on least mean square adaptive filter and recursive least-squares adaptive filter, are employed in order to combat the performance loss caused by the time-varying channels. Numerical results show that the proposed sphere decoder and these two channel tracking algorithms perform well in MBM systems.


Electronics ◽  
2020 ◽  
Vol 9 (5) ◽  
pp. 866
Author(s):  
Farzad Mohaddes ◽  
Rafael da Silva ◽  
Fatma Akbulut ◽  
Yilu Zhou ◽  
Akhilesh Tanneeru ◽  
...  

The performance of a low-power single-lead armband in generating electrocardiogram (ECG) signals from the chest and left arm was validated against a BIOPAC MP160 benchtop system in real-time. The filtering performance of three adaptive filtering algorithms, namely least mean squares (LMS), recursive least squares (RLS), and extended kernel RLS (EKRLS) in removing white (W), power line interference (PLI), electrode movement (EM), muscle artifact (MA), and baseline wandering (BLW) noises from the chest and left-arm ECG was evaluated with respect to the mean squared error (MSE). Filter parameters of the used algorithms were adjusted to ensure optimal filtering performance. LMS was found to be the most effective adaptive filtering algorithm in removing all noises with minimum MSE. However, for removing PLI with a maximal signal-to-noise ratio (SNR), RLS showed lower MSE values than LMS when the step size was set to 1 × 10−5. We proposed a transformation framework to convert the denoised left-arm and chest ECG signals to their low-MSE and high-SNR surrogate chest signals. With wide applications in wearable technologies, the proposed pipeline was found to be capable of establishing a baseline for comparing left-arm signals with original chest signals, getting one step closer to making use of the left-arm ECG in clinical cardiac evaluations.