Research on the Construction Quality Control of Unbonded Prestressed Concrete

2014 ◽  
Vol 501-504 ◽  
pp. 2195-2198
Author(s):  
Guo Hui Jin ◽  
Xiao Dan Niu ◽  
Xiao Li Wang

On account of unbonded prestressed concrete construction technology is a high demand specialized, strict operation, high technical content job [, so the construction quality control study of unbonded prestressed concrete play a vital role to the quality of the structure construction, impact the quality of the whole project. In view of this, this paper analysis and inductive the main point of it from three stages: before, under and after the construction, expect to play a role of reference and guidance to the engineering practice.

2012 ◽  
Vol 204-208 ◽  
pp. 2278-2281
Author(s):  
Hong Wei Liu

With the development of prestressing technology, steel strand first should the hollow plate beam of prestressed concrete get in the upper part structure of the highway bridge extensive application, to steel strand first should prestressed concrete hollow plate beam construction quality of quality, not only direct relation arrive bridge of normal usage, also in the meantime relation arrive bridge of safety degree and durable. Therefore acquaint with in the beam system make the process with control first a construction a craft with work well quality control the key being very. This text combine a construction to practice, to steel strand first should prestressed concrete hollow plate beam construction craft, quality control the etc problem make an introduction.


2020 ◽  
Vol 2 (3) ◽  
pp. 84
Author(s):  
Wending Zhang

<p>Mechanical and electrical installation is a very important construction technology in construction engineering. From the perspective of the construction unit, whether the installation technology and procedure are scientific and reasonable will have a direct impact on the final quality of the project, and it is also closely related to the personal and property safety of the residents. Based on this, construction organizers should construct and perfect a standardized installation construction quality management system, clarify management regulations, and control key technical points, so as to comprehensively improve the quality of electromechanical installation projects and improve the project qualification rate. This article will describe the construction technology and quality control strategy of electromechanical installation engineering, aiming to lay a theoretical foundation for the improvement of engineering qualification rate and construction quality.</p>


Author(s):  
Jin Ma

Abstract: the construction method of continuous paving of the upper and lower base of the water stable macadam base can improve the construction efficiency, overcome the quality problems of the traditional layered paving of the upper and lower base, such as untimely curing, slow construction, poor interlayer bonding, contraction joint and interlayer, so as to ensure the construction quality of the water stable macadam. It is also the promotion and application of new technology.


2012 ◽  
Vol 178-181 ◽  
pp. 1194-1197
Author(s):  
Pei Feng Cheng ◽  
Hai Long Liu

The paper based on the early diseases in the construction discussed the construction quality control through raw material experiment,mix design,test data of indoor test and field test and the construction technology of the cement stabilized gravel base,analyzed the early diseases phenomenon,such as early cracks,frozen block,segregation in the construction.And proposed the feasible measures so as to ensure the construction quality of cement stabilized macadam.


2014 ◽  
Vol 1055 ◽  
pp. 139-142
Author(s):  
Ming Yang ◽  
Hui Wang ◽  
Feng He ◽  
Qing Min Liu

This paper describes the importance of increasing control of technology and quality of road bridge construction and puts forwards effective measures to control the proposed road bridge construction technology and quality. Road bridge engineering is a basic livelihood projects while also ensuring economic and social development, but in recent years the reports about the quality of bridge construction repeatedly appeared in press which highlighting the poor construction quality control.


1977 ◽  
Vol 60 (5) ◽  
pp. 1097-1104
Author(s):  
Keijo I Aspila ◽  
John M Carron ◽  
Alfred S Y Chau

Abstract An interlaboratory quality control study was conducted to provide information to 5 participating Canadian laboratories on their capability in analyzing natural waters for 10 pesticides. The study was designed to identify the quality of each laboratory’s working standards for 15 organochlorine pesticides, and the accuracy and precision of each laboratory’s analytical procedures. Fifteen samples were provided, of which 3 were standards prepared for direct injection into an electron capture gas chromatograph. Instructions were provided to use these 3 standards for quantitating the pesticide content (8–150 ng/L) in 5 pairs of 1 L water samples. These paired samples contained 10 organochlorine pesticides approaching natural levels. Results of the study indicated that participants were fairly precise and achieved the designed ratio 1.5 for concentrations in the paired samples.


2011 ◽  
Vol 71-78 ◽  
pp. 4115-4119
Author(s):  
Xiao Qiu Ma

To ensure the construction quality of EPS external wall thermal insulation system , need to controll raw materials, construction conditions, construction methods and quality control acceptance criteria and other aspects


Author(s):  
Heng Zhang ◽  
Xuguang Zheng ◽  
Jing Zhou

In the process of reconstruction and extension of highways, the most important thing is to ensure that the overall level of the widening of interchanges is comprehensively improved to ensure safe traffic. However, due to the heavy and difficult tasks in the widening of interchanges, higher requirements are put forward for the construction quality of the project. In the actual construction of the project, it is necessary to actively analyze and explain the specific construction of the interchange widening project to ensure that the improvement level of the interchange widening in highway reconstruction and extension project is effectively upgraded. This paper gives a detailed introduction to the main construction technology for interchange widening project, clarifies the technical points of safety and guaranteed access, and proposes corresponding safeguard measures to ensure the comprehensive upgrade of the construction quality and standard of interchange widening in highway reconstruction and extension.


2020 ◽  
Vol 2 (2) ◽  
pp. 58
Author(s):  
Zichuan Huang

<p>Nowadays, with the continuous development of economy and society, the frequency of electromechanical installation projects in various industries is getting higher and higher. With the continuous improvement of mechanization level, the requirements for business personnel engaged in mechanical and electrical installation engineering are getting higher and higher. Electromechanical installation is a very important part in construction engineering. Only through continuous innovation, technical renewal and transformation, can the engineering function be effectively guaranteed and the economic benefit be increased. As urban construction enters the fast lane, people's requirements for the quality of life are gradually improved. The installation of construction electromechanical projects is the most prominent link in construction engineering, so construction units should pay attention to the installation of engineering electromechanical projects. The emphasis of engineering electromechanical installation is the control of installation quality and the innovation of installation technology. Based on the author's practical experience, this article first emphasizes the necessity of electromechanical installation, and then explains the relationship between construction engineering and electromechanical installation in combination with engineering practice, aiming at emphasizing the irreplaceable role of electromechanical installation in construction engineering.</p>


Sign in / Sign up

Export Citation Format

Share Document