Numerical Simulation of Temperature Profile in a Compartment Fire with a Roof Opening

2012 ◽  
Vol 538-541 ◽  
pp. 989-992 ◽  
Author(s):  
Jin Mei Li ◽  
Qiang Li ◽  
Yan Lei Dong ◽  
Chang Hai Li

Fifteen numerical simulations are presented in this article to investigate the influence of roof opening size and fire source size on gas temperature profiles in a compartment. The fire source size has a significant impact on the temperature hot smoke layer. The temperature of hot smoke layer increases as the increase of fire source size. The roof opening has cooling function to gas temperature in the compartment especially for large roof opening. The temperatures of hot smoke layer decrease with the roof opening size increase in all cases.

2019 ◽  
Vol 492 (2) ◽  
pp. 2095-2118
Author(s):  
Dong-Woo Kim ◽  
Liam Traynor ◽  
Alessandro Paggi ◽  
Ewan O'Sullivan ◽  
Craig Anderson ◽  
...  

ABSTRACT Using the data products of the Chandra Galaxy Atlas (Kim et al.), we have investigated the radial profiles of the hot gas temperature in 60 early-type galaxies (ETGs). Considering the characteristic temperature and radius of the peak, dip, and break (when scaled by the gas temperature and virial radius of each galaxy), we propose a universal temperature profile of the hot halo in ETGs. In this scheme, the hot gas temperature peaks at RMAX = 35 ± 25 kpc (or ∼0.04 RVIR) and declines both inward and outward. The temperature dips (or breaks) at RMIN (or RBREAK) = 3–5 kpc (or ∼0.006 RVIR). The mean slope between RMIN (RBREAK) and RMAX is 0.3 ± 0.1. Allowing for selection effects and observational limits, we find that the universal temperature profile can describe the temperature profiles of 72 per cent (possibly up to 82 per cent) of our ETG sample. The remaining ETGs (18 per cent) with irregular or monotonically declining profiles do not fit the universal profile and require another explanation. The temperature gradient inside RMIN (RBREAK) varies widely, indicating different degrees of additional heating at small radii. Investigating the nature of the hot core (HC with a negative gradient inside RMIN), we find that HC is most clearly visible in small galaxies. Searching for potential clues associated with stellar, active galactic nucleus (AGN) feedback, and gravitational heating, we find that HC may be related to recent star formation. But we see no clear evidence that AGN feedback and gravitational heating play any significant role for HC.


2012 ◽  
Vol 224 ◽  
pp. 418-421 ◽  
Author(s):  
Jin Mei Li ◽  
Qiang Li ◽  
Jia Qing Zhang ◽  
Chang Hai Li

The influence of roof vent area and fire source area on smoke exhaust function of roof vent is provided in this paper. Numerical simulation results show that the temperature of hot smoke layer increases with the increases of heat release rate and decreases as the roof vent area increases. For the evaluation criterion with temperature difference, with the increase in roof vent area and fire source area, the smoke exhausts function of roof vent was enhanced. But for the evaluation criterion with efficiency of smoke exhaust, the smoke exhaust efficiency increases as the roof vent area increase and decreases with the increases of fire source area.


2009 ◽  
Vol 131 (3) ◽  
Author(s):  
Thomas Povey ◽  
Imran Qureshi

The importance of understanding the impact of hot-streaks, and temperature distortion in general, on the high pressure turbine is widely appreciated, although it is still generally the case that turbines are designed for uniform inlet temperature—often the predicted peak gas temperature. This is because there is an insufficiency of reliable experimental data both from operating combustors and from rotating turbine experiments in which a combustor representative inlet temperature profile has accurately been simulated. There is increasing interest, therefore, in experiments that attempt to address this deficiency. Combustor (hot-streak) simulators have been implemented in six rotating turbine test facilities for the study of the effects on turbine life, heat transfer, aerodynamics, blade forcing, and efficiency. Three methods have been used to simulate the temperature profile: (a) the use of foreign gas to simulate the density gradients that arise due to temperature differences, (b) heat exchanger temperature distortion generators, and (c) cold gas injection temperature distortion generators. Since 2004 three significant new temperature distortion generators have been commissioned, and this points to the current interest in the field. The three new distortion generators are very different in design. The generator designs are reviewed, and the temperature profiles that were measured are compared in the context of the available data from combustors, which are also collected. A universally accepted terminology for referring to and quantifying temperature distortion in turbines has so far not developed, and this has led to a certain amount of confusion regarding definitions and terminology, both of which have proliferated. A simple means of comparing profiles is adopted in the paper and is a possible candidate for future use. New whole-field combustor measurements are presented, and the design of an advanced simulator, which has recently been commissioned to simulate both radial and circumferential temperature nonuniformity profiles in the QinetiQ/Oxford Isentropic Light Piston Turbine Test Facility, is presented.


2013 ◽  
Vol 13 (9) ◽  
pp. 2223-2238 ◽  
Author(s):  
A. Boilley ◽  
J.-F. Mahfouf

Abstract. The Nice Côte d'Azur international airport is subject to horizontal low-level wind shears. Detecting and predicting these hazards is a major concern for aircraft security. A measurement campaign took place over the Nice airport in 2009 including 4 anemometers, 1 wind lidar and 1 wind profiler. Two wind shear events were observed during this measurement campaign. Numerical simulations were carried out with Meso-NH in a configuration compatible with near-real time applications to determine the ability of the numerical model to predict these events and to study the meteorological situations generating an horizontal wind shear. A comparison between numerical simulation and the observation dataset is conducted in this paper.


2012 ◽  
Vol 166-169 ◽  
pp. 2726-2730
Author(s):  
Bo Si Zhang ◽  
Shou Xiang Lu

Subway plays an important role in urban transport system. Fire as the major risk of the subway, is gaining increasing concern. In this study, fire simulation is performed to estimate fire safety of different compartments of the subway train. Result shows that the two compartments in the middle become dangerous at 150s and the compartments in the two ends are not safe at 300s approximately. The other two compartments are always safe during the simulation time.


Author(s):  
Anahita Ayasoufi ◽  
Theo G. Keith ◽  
Ramin K. Rahmani

An improvement is introduced to the conservation element and solution element (CE/SE) phase change scheme presented previously. The improvement addresses a well known weakness in numerical simulations of the enthalpy method when the Stefan number, (the ratio of sensible to latent heat) is small (less than 0.1). Behavior of the improved scheme, at the limit of small Stefan numbers, is studied and compared with that of the original scheme. It is shown that high dissipative errors, associated with small Stefan numbers, do not occur using the new scheme.


2012 ◽  
Vol 2 (1) ◽  
Author(s):  
Krzysztof Wołosz ◽  
Jacek Wernik

AbstractThe paper presents the part of the investigation that has been carried out in order to develop the pneumatic pulsator which is to be employed as an unblocking device at lose material silo outlets. The part of numerical simulation is reported. The fluid dynamics issues have been outlined which are present during supersonic airflow thought the head of the pulsator. These issues describe the pneumatic impact phenomenon onto the loose material bed present in the silo to which walls the pulsator is assembled. The investigation presented in the paper are industrial applicable and the result is the working prototype of the industrial pneumatic pulsator. The numerical simulation has led to change the piston shape which is moving inside the head of the pulsator, and therefore, to reduce the pressure losses during the airflow. A stress analysis of the pulsator controller body has been carried out while the numerical simulation investigation part of the whole project. The analysis has made possible the change of the controller body material from cast iron to aluminium alloy.


Author(s):  
Aleksei S. Tikhonov ◽  
Andrey A. Shvyrev ◽  
Nikolay Yu. Samokhvalov

One of the key factors ensuring gas turbine engines (GTE) competitiveness is improvement of life, reliability and fuel efficiency. However fuel efficiency improvement and the required increase of turbine inlet gas temperature (T*g) can result in gas turbine engine life reduction because of hot path components structural properties deterioration. Considering circumferential nonuniformity, local gas temperature T*g can reach 2500 K. Under these conditions the largest attention at designing is paid to reliable cooling of turbine vanes and blades. At present in design practice and scientific publications comparatively little attention is paid to detailed study of turbine split rings thermal condition. At the same time the experience of modern GTE operation shows high possibility of defects occurrence in turbine 1st stage split ring. This work objective is to perform conjugate numerical simulation (gas dynamics + heat transfer) of thermal condition for the turbine 1st stage split ring in a modern GTE. This research main task is to determine the split ring thermal condition by defining the conjugate gas dynamics and heat transfer result in ANSYS CFX 13.0 package. The research subject is the turbine 1st stage split ring. The split ring was simulated together with the cavity of cooling air supply from vanes through the case. Besides turbine 1st stage vanes and blades have been simulated. Patterns of total temperature (T*Max = 2000 °C) and pressure and turbulence level at vanes inlet (19.2 %) have been defined based on results of calculating the 1st stage vanes together with the combustor. The obtained results of numerical simulation are well coherent with various experimental studies (measurements of static pressure and temperature in supply cavity, metallography). Based on the obtained performance of the split ring cooling system and its thermal condition, the split ring design has been considerably modified (one supply cavity has been split into separate cavities, the number and arrangement of perforation holes have been changed etc.). All these made it possible to reduce considerably (by 40…50 °C) the split ring temperature comparing with the initial design. The design practice has been added with the methods which make it possible to define thermal condition of GTE turbine components by conjugating gas dynamics and heat transfer problems and this fact will allow to improve the designing level substantially and to consider the influence of different factors on aerodynamics and thermal state of turbine components in an integrated programming and computing suite.


Author(s):  
Mojtaba Fardi ◽  
Yasir Khan

The main aim of this paper is to propose a kernel-based method for solving the problem of squeezing Cu–Water nanofluid flow between parallel disks. Our method is based on Gaussian Hilbert–Schmidt SVD (HS-SVD), which gives an alternate basis for the data-dependent subspace of “native” Hilbert space without ever forming kernel matrix. The well-conditioning linear system is one of the critical advantages of using the alternate basis obtained from HS-SVD. Numerical simulations are performed to illustrate the efficiency and applicability of the proposed method in the sense of accuracy. Numerical results obtained by the proposed method are assessed by comparing available results in references. The results demonstrate that the proposed method can be recommended as a good option to study the squeezing nanofluid flow in engineering problems.


Geophysics ◽  
2021 ◽  
pp. 1-69
Author(s):  
Artur Posenato Garcia ◽  
Zoya Heidari

The dielectric response of rocks results from electric double layer (EDL), Maxwell-Wagner (MW), and dipolar polarizations. The EDL polarization is a function of solid-fluid interfaces, pore water, and pore geometry. MW and dipolar polarizations are functions of charge accumulation at the interface between materials with contrasting impedances and the volumetric concentration of its constituents, respectively. However, conventional interpretation of dielectric measurements only accounts for volumetric concentrations of rock components and their permittivities, not interfacial properties such as wettability. Numerical simulations of dielectric response of rocks provides an ideal framework to quantify the impact of wettability and water saturation ( Sw) on electric polarization mechanisms. Therefore, in this paper we introduce a numerical simulation method to compute pore-scale dielectric dispersion effects in the interval from 100 Hz to 1 GHz including impacts of pore structure, Sw, and wettability on permittivity measurements. We solve the quasi-electrostatic Maxwell's equations in three-dimensional (3D) pore-scale rock images in the frequency domain using the finite volume method. Then, we verify simulation results for a spherical material by comparing with the corresponding analytical solution. Additionally, we introduce a technique to incorporate α-polarization to the simulation and we verify it by comparing pore-scale simulation results to experimental measurements on a Berea sandstone sample. Finally, we quantify the impact of Sw and wettability on broadband dielectric permittivity measurements through pore-scale numerical simulations. The numerical simulation results show that mixed-wet rocks are more sensitive than water-wet rocks to changes in Sw at sub-MHz frequencies. Furthermore, permittivity and conductivity of mixed-wet rocks have weaker and stronger dispersive behaviors, respectively, when compared to water-wet rocks. Finally, numerical simulations indicate that conductivity of mixed-wet rocks can vary by three orders of magnitude from 100 Hz to 1 GHz. Therefore, Archie’s equation calibrated at the wrong frequency could lead to water saturation errors of 73%.


Sign in / Sign up

Export Citation Format

Share Document