Bond Strength of Different Adhesive Luting Materials to Zirconia Ceramics

2012 ◽  
Vol 512-515 ◽  
pp. 447-450
Author(s):  
Qi Liu ◽  
Long Quan Shao ◽  
Chen Hu ◽  
Yuan Fu Yi ◽  
Bin Deng ◽  
...  

To investigate the bond strength of different adhesive luting materials bond to zirconia ceramics. 40 (30mm×5mm×5mm) Cercon Smart Ceramics samples were divided into groups: (1) glass-ionomer bonded (control group), (2) Clearfil™ Repair bonded, (3) Panavia F bonded, (4) Variolink N bonded. Tensile bond strength and shear bond strength were evaluated after 24h storage at 37°C in distilled water. Each group had 10 samples for different test. Data were evaluated using ANOVA analysis (α=0.05). The experiment groups are statistically significant differences with control group (P<0.05). The shear bond strength of the Glass ionomer FX Ι, the Clearfil™ Repair, Panavia F and Variolink N groups were 14.23±4.48 MPa, 21.95±1.32 MPa, 31.16±1.50 MPa and 43.54±1.97 MPa, separately. Comparisons among groups were significant differences (P<0.001). Variolink N bonded ceramics achieved highest tensile and shear bond strength. Different adhesive materials significantly influence the bond strength of zirconia ceramics.

2004 ◽  
Vol 12 (3) ◽  
pp. 200-204 ◽  
Author(s):  
Gisele Maria Correr ◽  
Angela S. Caldo-Teixeira ◽  
Roberta Caroline Bruschi Alonso ◽  
Regina Maria Puppin-Rontani ◽  
Mário Alexandre Coelho Sinhoreti ◽  
...  

The aim of this study was to evaluate the effect of saliva contamination (SCT) and re-etching time (RET) on the shear bond strength (SBS) of the Fluroshield sealant. Forty-five extracted third molars were sectioned and flattened until reach an enamel surface area. Then, all samples were etched for 30 sec with 35% phosphoric acid and then they were distributed into 9 groups (n=10) according to SCT and RET (seconds), respectively: G1- control (no SCT and no RET); G2- 30s and 0s; G3- 60s and 0s; G4-30s and 2s; G5- 30s and 5s; G6- 30s and 15s; G7-60s and 2s; G8- 60s and 5s; G9- 60s and 15s. The sealant was applied according to the manufacturer's instructions. The samples were stored in distilled water at 37ºC for 72h and subjected to the SBS test. The results indicated that there was no statistically significant difference between the groups (p>0.05). However, it could be noticed that: 1- the longer the SCT, the lower the SBS values; 2 - the longer the RET, the higher the SBS values. It could be concluded that there was a tendency to the shortest SCT (30s) associated to the longest RET (5 and 15s) to reach similar SBS values for the control group.


2013 ◽  
Vol 1 (2) ◽  
pp. 175
Author(s):  
Bernardo Urbanetto Peres ◽  
Felipe Weidenbach Degrazzia ◽  
Renésio Armindo Ghers ◽  
Fabíola Rossato Arrais ◽  
Vilmar Antonio Ferrazzo

PURPOSE: To evaluate the shear bond strength (SBS) of metallic brackets bonded with Transbond Plus Self-Etching Primer (TPSEP) and Transbond Plus Color Change (TPCC) under contamination with a mixture of saliva and blood. MATERIALS AND METHODS: 42 human premolars were randomly divided into 2 groups (n=21). Group 1 (G1) were bonded under no contamination, and Group 2 (G2) was contaminated with saliva/blood before bonding. Both groups were bonded according to the manufacturer’s instructions and were cleaned with pumice before bonding. The shear bond strength (SBS) tests were performed after 24 hours in distilled water at 37°C and after thermocycling. RESULTS: Both groups showed a homogeneous distribution in the Levene’s test (p>0.05). The main shear bond strength value of G1 was 8.89 MPa with a standard deviation of 2.27; the value for G2 was 6.00 MPa with a standard deviation of 2.62 MPa. There was a significant difference between G1 and G2 (t-student test p<0.05). IRA scores indicated that the main value was IRA 0, and no significant difference (α=0.05) was found between the groups. CONCLUSION: Contamination of blood mixed with saliva significantly decreases the shear bond strength, but even so, the performance is clinically acceptable.


2020 ◽  
pp. 030157422095904
Author(s):  
Sanad Kumar Singh Solanki ◽  
Yogesh Gupta ◽  
Varunjeet Chaudhary ◽  
Thiyam Nickychandra ◽  
Shubhuda Pai ◽  
...  

Aims and Objectives: To evaluate the influence of the two adhesion boosters (assure universal bonding resin and enhance adhesion booster) on the shear bond strengths of indirectly bonded lingual brackets. Materials and Methods: A total of 120 extracted human teeth were randomly divided into 3 groups (n = 40), each group contained equal number of anterior and posterior teeth (anterior = 20, posterior = 20), and their lingual surfaces were etched by using 37% phosphoric acid. The bracket was bonded indirectly without using adhesion booster in group 1 (control group). In group 2, the adhesion booster A (enhance adhesion booster) and adhesion booster B (assure universal bonding resin) in group 3 were applied, respectively, before the bonding. The universal testing machine was used to measure the maximum bond strength. Student’s t-test followed by the one-way analysis of variance was used to compare shear bond strength among the groups. Results: The shear bond strength was found to be highest in group 3, followed by group 2, and it was least in controls. There were highly significant differences statistically in shear bond strength among the groups 1, 2, and 3 ( P = .001). Conclusion: Shear bond strength was admissible in all the groups. The application of the assure universal bonding resin significantly increased the bond strength of lingual brackets in indirect bonding.


2019 ◽  
Vol 13 (01) ◽  
pp. 075-081 ◽  
Author(s):  
Tool Sriamporn ◽  
Ploypim Kraisintu ◽  
Lily Pachanin See ◽  
Somporn Swasdison ◽  
Awiruth Klaisiri ◽  
...  

Abstract Objective The aim of this study was to evaluate the effect of neutralizing agents on the shear bond strength of hydrofluoric (HF)–etched porcelain in nonaging and aging conditions. Subjects and Methods One hundred and twenty feldspathic porcelain specimens were prepared and divided into six groups to undergo different surface conditioning methods—group 1: control; group 2: HF; group 3: HF + calcium hydroxide; group 4: HF + calcium carbonate; group 5: HF + calcium gluconate; and group 6: HF + ultrasonic. All samples were immersed in 37°C distilled water for 24 h. Half of the samples were thermocycled in water for 5,000 cycles. The shear bond strength test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min. Data were statistically analyzed by two-way ANOVA and Tukey's multiple comparison test at a 95% confidence level. The surface micromorphology and surface elements were analyzed using scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDX), respectively. Results The shear bond strengths of groups 2–6 were significantly higher than the control group in both aging and nonaging conditions (p < 0.05). There were no significant differences among all of the HF-etched porcelain groups (p > 0.05). SEM images of groups 2–6 illustrated similar patterns of irregularity on the specimen surfaces. Elemental analysis of EDX demonstrated identical elements on surfaces of specimens of groups 2–6. Conclusion Within the limitations of this study, shear bond strength values between HF-etched porcelain, HF-etching followed by application of neutralizing agents, and HF-etching followed by ultrasonic cleaning were not significantly different in both nonaging and aging conditions.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yomna A. Nabawy ◽  
Tarek N. Yousry ◽  
Nadia M. El-Harouni

Abstract Background Increased risk of enamel demineralization during and after orthodontic treatment raises the demand for better preventive measures including combinations of laser, CPP-ACP, and fluoride. The combination of Er,Cr:YSGG laser with CPP-ACP was proved to have a synergetic effect compared to each of them alone. Shear bond strength (SBS) of orthodontic brackets bonded to the enamel surface after being treated with preventive measures is critical. The aim of this study was to compare the SBS and failure mode of metallic brackets bonded to teeth with no pretreatment and pretreated enamel surface, either with Er,Cr:YSGG laser alone or combined with CPP-ACP. Methods Sixty sound extracted human premolar teeth were allocated randomly to 3 groups: In Group 1 (control), teeth were etched and bonded directly; in Group 2, laser pretreatment of the enamel surface was done followed by etching and bonding as in the control group; in Group 3, the enamel surface was lased then CPP-ACP was applied according to the manufacturer instructions, etched and bonded. SBS and Adhesive remnant index (ARI) were evaluated. Results No significant differences were found between the 3 groups neither in the SBS nor in the ARI scores. Conclusions The use of combined Er,Cr:YSGG laser with CPP-ACP as a preventive measure before bonding orthodontic brackets does not endanger the bracket’s bonding strength.


2009 ◽  
Vol 56 (3) ◽  
pp. 117-122 ◽  
Author(s):  
Vladimir Mitic

Introduction. A great number of techniques have been used for bonding orthodontic brackets to the tooth surfaces. Glass ionomer cements are frequently used material for this purpose. The aim of this study was to measure the shear bond strength of orthodontic brackets bonded with glass ionomer cement Ortho Fuji LC and remained adhesive on the enamel surface after brackets debonding. Material and methods. A total of 40 extracted premolars for orthodontic reasons in different gender patients, 10-16 years old, were randomly divided into four groups. Using glass ionomer cement Ortho Fuji LC (Tokyo, Japan) stainless steel brackets were bonded to the teeth with the average surface area of the bracket base of 14.7 mm2. The shear bond strengths were measured at a crosshead speed of 1 mm per minute, and the load applied at the time of fracture was recorded using electronic dynamometer. Remained adhesive on the enamel after bracket debonding was evaluated using the adhesive remnant index (ARI). Results. Shear bond strength had the highest value for the group where enamel was etched right before bonding bracket (9.14 MPa), than in the group 2 (7.43 MPa), while in the groups 1 (6.72 MPa) and 3 (6.22 MPa), where etching was not performed, bond strength was lower. Conclusion. Shear bond strength of orthodontic brackets bonded with glass ionomer cement Ortho Fuji LC had higher values when the enamel was etched than without etching.


2017 ◽  
Vol 22 (4) ◽  
pp. 53-60 ◽  
Author(s):  
Nasrin Farhadian ◽  
Loghman Rezaei-Soufi ◽  
Seyed Farzad Jamalian ◽  
Maryam Farhadian ◽  
Shahrzad Tamasoki ◽  
...  

ABSTRACT Introduction: Many patients seeking orthodontic treatment already have incipient enamel lesions and should be placed under preventive treatments. The aim of this in vitro study was to evaluate the effect of CPP-ACP paste and CO2 laser irradiation on demineralized enamel microhardness and shear bond strength of orthodontic brackets. Methods: Eighty caries-free human premolars were subjected to a demineralization challenge using Streptococcus mutans. After demineralization, the samples were randomly divided into five equal experimental groups: Group 1 (control), the brackets were bonded without any surface treatment; Group 2, the enamel surfaces were treated with CPP-ACP paste for 4 minutes before bonding; Group 3, the teeth were irradiated with CO2 laser beams at a wavelength of 10.6 µm for 20 seconds. The samples in Groups 4 and 5 were treated with CO2 laser either before or through CPP-ACP application. SEM photomicrographs of a tooth from each group were taken to observe the enamel surface. The brackets were bonded to the buccal enamel using a conventional method. Shear bond strength of brackets and ARI scores were measured. Vickers microhardness was measured on the non-bonded enamel surface. Data were analyzed with ANOVA and Tukey test at the p< 0.05 level. Results: The mean shear bond strength and microhardness of the laser group were higher than those in the control group and this difference was statistically significant (p< 0.05). All groups showed a higher percentage of ARI score 4. Conclusion: CO2 laser at a wavelength of 10.6 µm significantly increased demineralized enamel microhardness and enhanced bonding to demineralized enamel.


2013 ◽  
Vol 07 (01) ◽  
pp. 055-060 ◽  
Author(s):  
Mehmet Akin ◽  
Sertac Aksakalli ◽  
Faruk Ayhan Basciftci ◽  
Abdullah Demir

ABSTRACTObjective: The purpose of this study was to determine the effect of 10% carbamide peroxide and 38% hydrogen peroxide bleaching agents on the shear bond strength of orthodontic brackets using self-etching primer systems.Methods: Forty five freshly extracted human premolar teeth were randomly divided into 3 groups of 15 teeth each: control (group 1), 10% carbamide peroxide at-home bleached (group 2), and 38% hydrogen peroxide in-office bleached (group 3). Three weeks later, all brackets were bonded using a self-etching primer system. The shear bond strength of these brackets was measured and recorded in MPa. Adhesive remnant index (ARI) scores were determined after the brackets failed. Data were analyzed using Kruskal- Wallis test, pairwise comparisons were made using the Mann-Whitney U test and ARI scores were analyzed using a chi-square test at a significance level of P<.05.Results: The shear bond strengths of group 1 (mean: 17.7 ± 9.7 MPa) were significantly higher (P<.05) than those of group 3 (mean: 9.9 ± 5.4 MPa). No significant differences were found between group 2 (mean: 12.3 ± 4.7) and either group 1 or group 3 (P>.05). ARI scores did not differ significantly among the 3 groups.Conclusions: The use of 10% carbamide peroxide bleaching does not significantly reduce shear bond strength values. In contrast, use of 38% hydrogen peroxide bleaching significantly reduces these values. (Eur J Dent 2013;7:55-60)


2020 ◽  
Vol 8 (3) ◽  
pp. 66
Author(s):  
Paul Nahas ◽  
Samir Nammour ◽  
Elie Gerges ◽  
Toni Zeinoun

(1) Background: Bonding composite to tooth structure is still evolving with a substitute for phosphoric acid being the main challenge. Lately, a self-adhering composite (SAC) was developed, promising to simplify bonding to tooth structure. Unfortunately, retention especially to dentin, was not as good as the gold standard three steps bonding system. During the last 2 decades, lasers were used to enhance shear bond strength of composite to tooth structure. However, the literature provided limited information regarding laser efficiency in the immediate, as well as the long term, adhesion success of SACs to dentin. The purpose of our study was to define the optimal irradiation conditions to improve the adhesion of self-adhering flowable resin composite to dentin exposed to Er:YAG and Er,Cr:YSGG laser irradiation. (2) Methods: Seventy-two freshly extracted human third molars, prepared to have flat dentinal surfaces, were randomly divided into three groups (n = 24) including a control group (Group 1) in which dentin was left without laser irradiation. The other two groups (Group 2 and 3) received standardized irradiation at a speed of 1 mm/second with Er:YAG (60 mJ; SSP mode = 50 μs; 10 Hz; fluency of 9.4 J/cm2; beam diameter: 0.9 mm; air 6 mL/min; and water 4 mL/min), and Er,Cr:YSGG: 1.5 W; fluency of 17.8 J/cm2; turbo handpiece with MX5 short insert; 20 Hz under air/water spray (65% air, 55% water). Self-adhering flowable resin was applied to dentin in all groups. Half of the specimens were stored in water for 24 h while the other half underwent 3000 thermal cycles. Later, all specimens received a shear bond strength test. Fracture observation was done first under a stereomicroscope then by using a scanning electron microscope. (3) Results: The mean values of shear bond strength for both laser-treated dentin groups (Er:YAG laser: 13.10 ± 1.291, and Er,Cr:YSGG: 14.04 ± 5.233) were higher than in the control group 1 (8.355 ± 2.297) before thermocycling. After thermocycling, shear bond strength decreased in all groups as follows: 10.03 ± 1.503, 10.53 ± 2.631, and 02.75 ± 1.583 for Er:YAG, Er,Cr:YSGG, and nonirradiated dentin, respectively. Shear bond strength values showed a significant difference between the control group (Group 1) and both lasers groups (Group 2 and 3). Statistical analysis of stereomicroscope observation revealed no significant difference between laser irradiation and failure mode (p < 0.136). SEM observation of the dentin surface in both laser-irradiated groups showed opened tubules, absence of smear layer as well as an increase of resin infiltration into dentinal tubules. (4) Conclusion: Er:YAG and Er,Cr:YSGG lasers enhance self-adhering flowable resin shear bond strength values and improve its longevity by eliminating the smear layer, opening dentinal tubules and increasing resin infiltration into the microstructure.


Materials ◽  
2019 ◽  
Vol 12 (23) ◽  
pp. 3922
Author(s):  
Francisco da Silva Araújo Milagres ◽  
Dauro Douglas Oliveira ◽  
Giordani Santos Silveira ◽  
Emanuelle de Fátima Ferreira Oliveira ◽  
Alberto Nogueira da Gama Antunes

The aim of this study was to evaluate the shear bond strength of orthodontic tubes adhered to ceramics with the Transbond™ XT bonding resin (3M, Maplewood, MN, USA) while varying the surface treatment. Then, the adhesive remaining index (ARI) was verified, and the representative fracture patterns were evaluated via scanning electron microscopy. Forty-eight zirconia blocks were divided into three groups, varying the number of layers of the 10-methacryloyloxy-decyl dihydrogen phosphate (MDP) primer: one, two, or three applications. In addition, 16 lithium disilicate IPS E.max ceramic disks (Ivoclar Vivadent, Schaan, Liechtenstein) were conditioned with 10% hydrofluoric acid for 20 s and underwent a single-layer primer application regimen. The four groups were further stratified to undergo bond testing after either 24 h (control) or 5000 cycles in a thermocycling machine. A shear bond strength test was performed (0.5 mm/min), and the MPa values obtained were submitted to a two-way analysis of variance and Tukey’s test. There was no statistical difference among the control group ceramics that received the varying surface treatments. After thermocycling, it was verified that both the E.max disks and the zirconia ceramics with three primer applications obtained the highest bond strength values. In the 24 h groups, a total displacement of the resin from the orthodontic tubes was observed (ARI of 1). After thermocycling, the highest prevalence of an ARI of 5 (adhesive failure) was observed among the zirconia ceramics with single-coat primer application, followed by those with triple-coat primer application (mixed failure). Three applications of the MDP-containing ceramic primer achieved the best result in the present study. Zirconia surface should be treated with three coats of MDP primer to achieve a level of bond strength similar to silica-rich phase ceramic.