Fast Preparation of Ultrathin FIB Lamellas for MEMs-Based In Situ TEM Experiments

2016 ◽  
Vol 850 ◽  
pp. 722-727 ◽  
Author(s):  
Hui Wang ◽  
Shang Gang Xiao ◽  
Qiang Xu ◽  
Tao Zhang ◽  
Henny Zandbergen

The preparation of thin lamellas by focused ion beam (FIB) for MEMS-based in situ TEM experiments is time consuming. Typically, the lamellas are of ~5μm*10μm and have a thickness less than 100nm. Here we demonstrate a fast lamellas’ preparation method using special fast cutting by FIB of samples prepared by conventional TEM sample preparation by argon ion milling or electrochemical polishing methods. This method has been applied successfully on various materials, such as ductile metallic alloy Ti68Ta27Al5, brittle ceramics K0.5Na0.5NbO3-6%LiNbO3 and semiconductor Si. The thickness of the lamellas depends on the original TEM sample.

Author(s):  
Hagit Barda ◽  
Irina Geppert ◽  
Avraham Raz ◽  
Rémy Berthier

Abstract An experimental setup is presented, that allows in-situ Transition Electron Microscopy (TEM) investigation of void formation and growth within fully embedded interconnect structure, as a response to an external bias. A special TEM holder is employed to perform in-situ I-V measurements across the Via, simultaneously monitoring the morphological and chemical changes surrounding the void. This work presents in detail a Focused Ion Beam (FIB) based sample preparation method that allows the analysis of a Cu single Via structure found in the advanced microelectronic 14nm FinFET technology, as well as preliminary TEM observations.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Seo-Jin Kim ◽  
Byung-Kyu Park ◽  
Christopher H. Kang

Abstract In semiconductor manufacturing technology, copper has been widely used for BEOL process due to better conductivity than aluminum. TEM (Transmission Electron Microscopy) characterization has been played in key role to understand the process of semiconductor manufacturing. Gallium base Focused Ion Beam (FIB) is widely used on TEM sample preparation. The experiment to understand the impact of gallium which is from sample preparation process on Cu layer was performed. In-situ TEM studies have shown real time material characteristic of Cu at various temperature [1]. We observed the gallium aggregation phenomenon on Cu layer at round the temperature of 400°C. This thermal aggregation of gallium on Cu layer has been confirmed by EDS analysis in the study. Detectable amount of gallium was found in whole area in the sample before heating the sample at in-situ TEM work. This paper also introduces alternative solutions to resolve this gallium aggregation in copper layer including the sample preparation technique using Xe Plasma Focused Ion Beam (PFIB) [2]. This Xe PFIB showed the substantial improvement of specimen quality for the in-situ TEM experiment of sample preparation.


2019 ◽  
Vol 126 (6) ◽  
pp. 065702 ◽  
Author(s):  
M. A. Gribelyuk ◽  
J. Mody ◽  
E. Kaganer ◽  
S. S. Furkay ◽  
J. Miller ◽  
...  

2018 ◽  
Author(s):  
C.S. Bonifacio ◽  
P. Nowakowski ◽  
M.J. Campin ◽  
M.L. Ray ◽  
P.E. Fischione

Abstract Transmission electron microscopy (TEM) specimens are typically prepared using the focused ion beam (FIB) due to its site specificity, and fast and accurate thinning capabilities. However, TEM and high-resolution TEM (HRTEM) analysis may be limited due to the resulting FIB-induced artifacts. This work identifies FIB artifacts and presents the use of argon ion milling for the removal of FIB-induced damage for reproducible TEM specimen preparation of current and future fin field effect transistor (FinFET) technologies. Subsequently, high-quality and electron-transparent TEM specimens of less than 20 nm are obtained.


Micron ◽  
2014 ◽  
Vol 58 ◽  
pp. 25-31 ◽  
Author(s):  
Neda Dalili ◽  
Peng Li ◽  
Martin Kupsta ◽  
Qi Liu ◽  
Douglas G. Ivey

2013 ◽  
Vol 19 (4) ◽  
pp. 1080-1091 ◽  
Author(s):  
Felipe Rivera ◽  
Robert Davis ◽  
Richard Vanfleet

AbstractTransmission electron microscopy (TEM) and focused ion beam (FIB) are proven tools to produce site-specific samples in which to study devices from initial processing to causes for failure, as well as investigating the quality, defects, interface layers, etc. However, the use of polymer substrates presents new challenges, in the preparation of suitable site-specific TEM samples, which include sample warping, heating, charging, and melting. In addition to current options that address some of these problems such as cryo FIB, we add an alternative method and FIB sample geometry that address these challenges and produce viable samples suitable for TEM elemental analysis. The key feature to this approach is a larger than usual lift-out block into which small viewing windows are thinned. Significant largely unthinned regions of the block are left between and at the base of the thinned windows. These large unthinned regions supply structural support and thermal reservoirs during the thinning process. As proof-of-concept of this sample preparation method, we also present TEM elemental analysis of various thin metallic films deposited on patterned polycarbonate, lacquer, and poly-di-methyl-siloxane substrates where the pattern (from low- to high-aspect ratio) is preserved.


Author(s):  
C.S. Bonifacio ◽  
P. Nowakowski ◽  
R. Li ◽  
M.L. Ray ◽  
P.E. Fischione ◽  
...  

Abstract Fast and accurate examination from the bulk to the specific area of the defect in advanced semiconductor devices is critical in failure analysis. This work presents the use of Ar ion milling methods in combination with Ga focused ion beam (FIB) milling as a cutting-edge sample preparation technique from the bulk to specific areas by FIB lift-out without sample-preparation-induced artifacts. The result is an accurately delayered sample from which electron-transparent TEM specimens of less than 15 nm are obtained.


Sign in / Sign up

Export Citation Format

Share Document