scholarly journals Tooth discoloration induced by calcium-silicate-based pulp-capping materials

2015 ◽  
Vol 09 (02) ◽  
pp. 165-170 ◽  
Author(s):  
Da-A Yun ◽  
Su-Jung Park ◽  
Seok-Ryun Lee ◽  
Kyung-San Min

ABSTRACT Objectives: The aim of this study was to evaluate tooth discoloration induced by contact with various calcium silicate-based pulp capping materials in the presence or absence of blood in vitro. Materials and Methods: Eighty bovine samples were divided into six experimental groups and two control groups according to the type of material used (ProRoot [PR], Endocem [EC], or EndocemZr [ECZ]) and the presence or absence of contamination with blood. A spectrophotometer was used to calculate the color difference (ΔE) between the baseline measurement (after placement of materials) and measurements taken 1, 2, 4, and 8 weeks. The results were analyzed with repeated measures analysis of variance, Tukey's post-hoc tests and independent t-tests (P = 0.05). Results: The PR group and EC group showed significantly higher mean values of ΔE than the negative control group after 2 weeks (P < 0.05), whereas ECZ did not. There were larger ΔE values when there was contact with blood, especially in PR and EC group (P < 0.05). Conclusions: ECZ which contains zirconium oxide as a radiopacifier showed less discoloration irrespective of blood contamination compared to PR and EC.

2021 ◽  
Author(s):  
Mehdi Dastorani ◽  
Muhammad javad Aliee ◽  
Raheleh Halabian ◽  
Mostafa Solati ◽  
Mohammadsadegh Alemrajabi

Abstract Background: This study aimed to assess the cytotoxicity of four commonly used endodontic sealers namely AH Plus, AdSeal, Endoseal MTA, and GuttaFlow Bioseal against human gingival fibroblasts (HGFs). Methods: After culturing the HGFs, they were exposed to the respective sealers in set form and in five different weights, after sterilization. The cytotoxicity of the sealers was evaluated after 1, 3 and 7 days using the methyl thiazolyl tetrazolium (MTT) assay. Data were analyzed by repeated measures ANOVA. Results: After 24 h, all sealers showed low cytotoxicity. However, all sealers in 250 mg and 500 mg weights showed significantly higher cytotoxicity than the negative control group at 72 h, and 7 days (P<0.05) except for AdSeal in 80 mg weight (P>0.05). AH Plus was significantly more cytotoxic than other sealers at 3 and 7 days (P<0.05) while AdSeal had the closest results to the negative control group, and showed significantly higher biocompatibility than other sealers in 250 mg concentration. Conclusion: AdSeal showed the highest biocompatibility while AH Plus had the highest cytotoxicity among the tested sealers. Thus, its application may delay the healing of periapical lesions.


Author(s):  
Ralf Krug ◽  
C. Ortmann ◽  
S. Reich ◽  
B. Hahn ◽  
G. Krastl ◽  
...  

Abstract Objectives To assess tooth discoloration induced by different hydraulic calcium silicate-based cements (HCSCs), including effects of blood and placement method. Materials and methods Eighty bovine teeth cut to a length of 18 mm (crown 8 mm, root 10 mm) were randomly assigned to 10 groups (n = 8), receiving orthograde apical plug treatment (APT). Apical plugs were 4 mm in length and made of ProRoot MTA (Dentsply), Medcem MTA (Medcem), TotalFill BC RRM Fast Set Putty (Brasseler), or Medcem Medical Portland Cement (Medcem) plus bismuth oxide (Bi2O3) with and without bovine blood. Further, orthograde (with or without preoperative adhesive coronal dentin sealing) and retrograde APT were compared. Teeth were obturated with gutta-percha and sealer, sealed with composite and stored in distilled water. Tooth color was measured on apical plug, gutta-percha/sealer, and crown surface before treatment versus 24 h, 1, 3, 6, 12, and 24 months after treatment by spectrophotometry. Color difference (ΔE) values were calculated and analyzed by Shapiro–Wilk test, ANOVA with post hoc tests, Friedman test, t test, and post hoc tests with Bonferroni correction (α = .05). Results Tooth discoloration occurred in all groups with no significant differences between HCSCs (p > .05). After 24 months, color changes were prominent on roots but insignificant on crowns. Blood contamination induced a significantly decreased luminescence (p < .05). Blood had a stronger impact on tooth color than Bi2O3. No relevant effects of retrograde placement (p > .05) or preoperative dentin sealing (p > .05) were detected. Conclusions Apical plugs of the tested HCSCs cause discoloration of bovine roots, but not discoloration of bovine tooth crowns within a 24-month period. Clinical relevance APT should be performed carefully while avoiding direct contact with the coronal dentin, and in that case no aesthetic impairments occur.


2018 ◽  
Vol 12 (3) ◽  
pp. 196-200
Author(s):  
Ajita Rathi ◽  
Prateeksha Chowdhry ◽  
Mamta Kaushik ◽  
Pallavi Reddy ◽  
Roshni Roshni ◽  
...  

Background. The present study was undertaken to evaluate the incidence of dentinal cracks during root canal preparation with different periodontal ligament simulating materials in vitro. Methods. Seventy freshly extracted human mandibular first premolars were selected and divided into 7 groups in terms of simulating material: group 1: polyether impression material; group 2: polyvinyl acetate adhesive; group 3: polyvinyl siloxane impression material; group 4: cyanoacrylate adhesive; group 5: epoxy resin adhesive; group 6: positive control, without any periodontal ligament simulation; and group 7: negative control, where neither a periodontal ligament simulating material was used nor canal preparation was carried out. Root canal preparation was carried out in all the groups followed by sectioning of roots at 3 mm, 6 mm and 9 mm. The sections were evaluated under a stereomicroscope at ×2.5 for the presence or absence of cracks. Chi-squared test was used to compare the appearance of defective roots between the different experimental groups. Results. The least number of cracks were found in the negative control group, followed by group 1 where polyether impression material was used for periodontal ligament simulation. The difference was significant with a P-value of 0.002 for coronal sections. Conclusion. Under the limitation of the present study, polyether and polyvinyl siloxane (light body) can both be used for simulation of periodontal ligament.


2016 ◽  
Vol 848 ◽  
pp. 567-572 ◽  
Author(s):  
Lin Wang ◽  
Shen Hua Song ◽  
Zheng Zhi Wu ◽  
Li Hong Duan ◽  
Chun Bao Wang

In order to evaluate the cytocompatibility and hemolytic properties of n-HA/PEEK biocomposites the nanohydroxyapatite/polyetheretherketone (n-HA/PEEK) biocomposites were successfully prepared. The mechanical properties of the biocomposites were proximal to human bone, at the same time, they had the optimal value with the HA volume content of 5%. The PEEK and n-HA/PEEK biocomposites with different HA content extraction medium was prepared with fresh medium. Simple DMEM culture solution was taken as negative control group. The pure PEEK and 5vol.%, 15vol.%, 30vol.% n-HA/PEEK biocomposites were the testing group. The relative proliferation rate of L929 cells was determined on the 1st, 2nd, 3rd and 6th days with CCK-8 assay. The cytotoxicity of n-HA/PEEK biocomposites were evaluated according to ISO 10993-5: 2009. The L929 cells morphology and growth on the 1st, 2nd, 3rd and 6th days were determined under inverted microscope. The hemolysis test in vitro of n-HA/PEEK biocomposites were evaluated through measuring erythrocyte lysis and ferro-hemoglobin freeing degree with indirect contact method basing on ISO 10993-4:2009. The experimental results showed that the growth and morphology of cells in pure PEEK and n-HA/PEEK biocomposites extraction medium had no difference from negative control group. Cytotoxicity test showed that PEEK and n-HA/PEEK biocomposites did not have obvious toxicity on L929 cells, and the cytotoxicity of these extracts was in grade 0-1. Hemolysis test suggested that PEEK and n-HA/PEEK biocomposites did not have obvious hemolysis reaction, and the hemolysis rate of PEEK and n-HA/PEEK biocomposites were 2.37%, 1.71%, 1.05% and 1.32% respectively, which are less than the national standard (5%). It may be concluded that the n-HA/PEEK biocomposites did not have obvious cytotoxicity and hemolysis reaction, which demonstrated that n-HA/PEEK biocomposites had good cytocompatibility.


2020 ◽  
Vol 6 (3) ◽  
pp. 157
Author(s):  
Adinningtyas Intansari ◽  
Al Munawir ◽  
Laksmi Indreswari

Physalia utriculus is one of the invertebrate marine biota that is often found in Indonesia. Some symptoms of venoming due to jellyfish stings cause pain, itching, and hemolysis. In Indonesia, 13 cases of jellyfish stings were reported in 2005-2009 with three people dying in Java, Bali, and Bangka. Cocoa beans (Theobroma cacao L.) contain fat, carbohydrates, proteins, and polyphenol compounds that are useful as antioxidants. Polyphenols in the form of epicathechins, catechins, and procyanidins serve to provide protection to hemolysis. The purpose of this study was to determine the potential of ethanol extract of cacao (Theobroma cacao L.) in inhibiting the damage of erythrocyte induced by Physalia utriculus in vitro. This study used 28 samples of erythrocytes divided into seven groups, namely the normal control group, negative controls, and treatment with cocoa ethanol extract 0.2%, 0.1%, 0.04%, and 0.02%. Each subsequent group induced venom Physalia utriculus. The results showed that the average speed of erythrocyte lysis in the treatment group by giving cocoa ethanol extract 0.2%, 0.1%, 0.04%, and 0.02% respectively (seconds ± standard deviation) was 858,25 ± 94,44; 1.000,5 ± 159,93; 678,5 ± 19,71; and 1.006 ± 159,50. The mean speed of erythrocyte lysis in the negative control group was 1,025 ± 164.63 and the positive control group with the administration of N-Acetylcystein can last up to one hour after administration of venoms. Test for normality and homogeneity shows that data is normally distributed and homogeneous. One Way Annova analysis shows the significance value of p <0.05, then a post hoc analysis test was performed with the Bonferoni method to find out the differences in significance in each group. In this study it can be concluded that the administration of cocoa ethanol extract has no potential to inhibit erythrocyte damage that has been venomed by Physalia utriculus in vitro. Keywords: Physalia utriculus, cacao, erythrocyte damage


2021 ◽  
Author(s):  
Muhammet Kerim Ayar ◽  
Onder Yesil

ABSTRACTObjectiveIn order to reduce the amount of aerosol during the use of dental adhesives, which are widely used in minimally invasive procedures, the effects of air stream-free adhesive drying methods on the enamel bond strength of resin adhesive systems were evaluated.Materials and MethodsThe four adhesive drying techniques used were an air-stream, a micro-applicator, a cotton pellet and an absorbent paper. Adhesive systems were Single Bond Universal and Optibond All-in-one. The group in which the adhesive was not dried served as the negative control group. Enamel shear bond strength was performed with a universal tester with a crosshead speed of 1 mm/min (n=12). A two-way analysis of variance and the Tukey post-hoc test were used for analysis of the SBS data.ResultsFor both adhesives, drying the adhesive with cotton pellet or micro-applicator provided a SBS mean values similar to air-stream drying, while statistically significantly lower SBS mean values were observed in the negative control group and in the absorbent paper-dry group compared to the air-drying group.ConclusionsDrying the adhesive with micro-applicator and cotton pellets creates less aerosol and thus can be used in the COVID-19 pandemic as it provides enamel bonding strength similar to air drying.CLINICAL SIGNIFICANCETo provide safer dental care during COVID-19 pandemic, it is highly recommended to use non-aerosol-generating alternatives, instead of aerosolgenerating dental procedures. In this study, we found that the aerosol generation-free methods for adhesive-drying such as cotton pellet and micro applicator drying methods provide similar enamel bonding with conventional drying method. We think that our findings will contribute to the realization of safer adhesive dentistry practice, especially during the COVID-19 pandemic.


2020 ◽  
Author(s):  
Manisha Nepal ◽  
Snigdha Shubham ◽  
Rupam Tripathi ◽  
Jwolan Khadka ◽  
Deepa Kunwar ◽  
...  

Abstract Background The present study compares the apical microleakage of three different root-end filling materials in which the retrograde cavity is prepared by two different burs. Methods Eighty extracted single rooted maxillary and mandibular premolars were taken. Root canal treatment was completed. Apical 3 mm of all the teeth were resected with diamond disk. The tooth were divided into four groups with two subgroups for each group containing 10 tooth (N= 10) as: Group IA (Negative Control and IB (Positive Control); Group IIA and IIB: Prepared with round carbide bur and round diamond bur respectively, filled with GIC; Group IIIA and IIIB: Prepared with round carbide bur and round diamond bur respectively, filled with MTA; Group IVA and IVB: Prepared with round carbide bur and round diamond bur, filled with Biodentine. After applying two coats of nail varnish leaving apical 3 mm (except for negative control group) all teeth were immersed in 2% methylene blue for 3 days and again in 65% nitric acid for next 3 days for extraction of dye. The obtained solution was then transferred to eppendorf tube and centrifuged in microcentrifuges at 14,000 revolution per minutes (RPM) for 5 minutes. Optical density or absorbance of the supernatant solution was measured with UV spectrophotometer at 550 nm. Results The absorbance of the supernatant solution after dye extraction is decreasing in the order of positive control> GIC> MTA> Biodentine> negative control group. The significant difference was observed between GIC and MTA (p=0.0001) and GIC and Biodentine (p=0.0001) with two different burs but statistically non-significant difference was observed between MTA and Biodentine with Carbide bur (p=0.127) and Diamond bur (p=0.496) respectively. Conclusions Within the limitations of the present study, it can be concluded that Biodentine and MTA showed less microleakage as compared to GIC. There is no significant difference between mean microleakage of MTA and Biodentine. However, the mean OD of the Biodentine was least of all evaluated materials. Preparation of the root-end using round carbide bur as well as round diamond burs showed comparable microleakage for all three filling materials.


2020 ◽  
Vol 54 (4) ◽  
pp. 336-342
Author(s):  
Philipp Körner ◽  
Jana A Schleich ◽  
Daniel B. Wiedemeier ◽  
Thomas Attin ◽  
Florian J. Wegehaupt

<b><i>Objectives:</i></b> This in vitro study aimed to evaluate and compare the effect of two different bioactive glasses, a hydroxyapatite-containing, fluoride-free toothpaste (HTP) and a fluoride toothpaste (FTP) on the remineralization behavior of initial caries lesions. <b><i>Materials and Methods:</i></b> A total of 100 bovine enamel samples were randomly allocated to five groups of 20 samples each: NC = negative control group (artificial saliva); HTP = HTP group (Karex); FTP = FTP group (Elmex caries protection, 1,400 ppm); FTP + BG<sub>nano</sub> = FTP followed by Actimins bioactive glass; FTP + BG<sub>amorph</sub> = FTP followed by Schott bioactive glass. Radiographic documentation (advanced transversal microradiography; aTMR) was applied before and after all samples were exposed to a demineralizing gel for 10 days. Over a period of 28 days, samples were covered twice a day (every 12 h) with a toothpaste slurry of the respective test group or with artificial saliva in NC for 60 s and brushed with 15 brushing strokes. Samples in FTP + BG<sub>nano</sub> and FTP + BG<sub>amorph</sub> were additionally treated with the respective bioactive glass slurry for 30 s after brushing with the FTP. In the meantime, all samples were stored in artificial saliva. After 28 days, the structure of all samples was assessed again using aTMR and compared to the values measured after demineralization. The statistical evaluation of the integrated mineral loss was performed using Kruskal-Wallis test followed by a post hoc Conover test. <b><i>Results:</i></b> The FTP revealed the significantly highest increase of mineral content while the HTP showed the significantly lowest remineralization. Compared to artificial saliva, the use of the HTP or the combined application of FTP followed by bioactive glasses (FTP + BG<sub>nano</sub> and FTP + BG<sub>amorph</sub>) showed no significant remineralization. <b><i>Conclusion:</i></b> Under remineralizing in vitro conditions, brushing with 1,400 ppm FTP induced significantly more remineralization compared to storage in artificial saliva. The additional administration of both bioactive glasses as well as the substitutional brushing with an HTP resulted in significantly less remineralization compared to brushing with 1,400 ppm FTP.


Author(s):  
P. M. Sonkusale ◽  
Pratik N. Inglepatil ◽  
Siddharth V. Jamadade

A total of 75 day old broiler chicks were divided into three equal groups. Group A served as negative control. Group B (positive control) and C (treatment group) were intoxicated with oral administration of CCl4 @ 1 ml/kg body weight after every 3rd day during 15-28 days of age. Group C was given AV/LCP/18 @ 0.10 ml / chick / day in drinking water during 29th-42nd day of age. At the end of experiment, significantly (P is less than 0.01) higher mean body weight and lower FCR was observed in treatment group C as compared to positive control group B. Similarly, significantly (P is less than 0.05) decreased levels of SGOT, SGPT, cholesterol, triglycerides, creatinine and higher mean values of serum protein profile along with mild degenerative changes in liver and kidney of broilers in group C were observed as compared to group B indicating therapeutic efficacy of AV/LCP/18 in ameliorating the toxic effects or FLKS induced by CCl4 in commercial broilers


2020 ◽  
Vol 7 ◽  
Author(s):  
Julia M. Souza ◽  
Érica A. A. de Carvalho ◽  
Ana Carolina B. B. Candido ◽  
Rafael P. de Mendonça ◽  
Maria Fernanda da Silva ◽  
...  

The efficacy of Licochalcone A (LicoA) and its two analogs were reported against Leishmania (Leishmania) amazonensis and Leishmania (Leishmania) infantum in vitro, and in experimental model of L. (L.) infantum in vitro. Initially, LicoA and its analogs were screened against promastigote forms of L. (L.) amazonensis. LicoA was the most active compound, with IC50 values of 20.26 and 3.88 μM at 24 and 48 h, respectively. Against amastigote forms, the IC50 value of LicoA was 36.84 μM at 48 h. In the next step, the effectivity of LicoA was evaluated in vitro against promastigote and amastigote forms of L. (L.) infantum. Results demonstrated that LicoA exhibited leishmanicidal activity in vitro against promastigote forms with IC50 values of 41.10 and 12.47 μM at 24 and 48 h, respectively; against amastigote forms the IC50 value was 29.58 μM at 48 h. Assessment of cytotoxicity demonstrated that LicoA exhibited moderate mammalian cytotoxicity against peritoneal murine macrophages; the CC50 value was 123.21 μM at 48 h and showed about 30% of hemolytic activity at concentration of 400 μM. L. (L.) infantum-infected hamsters and treated with LicoA at 50 mg/kg for eight consecutive days was able to significantly reduce the parasite burden in both liver and spleen in 43.67 and 39.81%, respectively, when compared with negative control group. These findings suggest that chalcone-type flavonoids can be a promising class of natural products to be considered in the search of new, safe, and effective compounds capable to treat canine visceral leishmaniosis (CVL).


Sign in / Sign up

Export Citation Format

Share Document