Comparison of the Nucleic Acid Amplification System NASBA® and Agar Isolation for Detection of Pathogenic Campylobacters in Naturally Contaminated Poultry

1996 ◽  
Vol 59 (7) ◽  
pp. 683-687 ◽  
Author(s):  
M. UYTTENDAELE ◽  
R. SCHUKKINK ◽  
B. VAN GEMEN ◽  
J. DEBEVERE

A total of 160 poultry products were examined for the presence of pathogenic campylobacters using the traditional agar isolation method and the nucleic acid amplification system NASBA®, both after a 24-h selective enrichment. Pathogenic campylobacters could be isolated from 92 of 160 (57.5%) samples using agar isolation, among which 79 (49.37%) were identified as Campylobacter jejuni, six (3.75%) as C. coli, five (3.12%) as C. lari, and two (1.25%) as unclassified. The NASBA® assay provides a specific and sensitive method for detection of these campylobacters. A total of 149 samples (93.12%) gave similar results for both the traditional isolation procedure on modified Campylobacter charcoal desoxycholate agar and the NASBA® enzyme-linked gel assay detection system. Two false-negative results were obtained with the agar isolation procedure. Nine false-positive results were reported when the NASBA® system was used. However, the high sensitivity of the NASBA® method and indications that in some cases the traditional isolation procedure failed (abundance of a contaminating noncampylobacter bacteria which grew on the Campylobacter selective media) raises doubt about the true nature of these false-positive results. The NASBA® detection assay offers a rapid and useful analytical method when screening for the presence of pathogenic campylobacters. The complete procedure, including 24 h of selective enrichment, required 32 h.

1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


PEDIATRICS ◽  
1987 ◽  
Vol 79 (2) ◽  
pp. 203-205
Author(s):  
Mendel Tuchman ◽  
Margaret L. R. Ramnaraine ◽  
William G. Woods ◽  
William Krivit

During the last 3 years, random urine samples from 408 patients were tested for elevated homovanillic acid (HVA) and vanillylmandelic acid (VMA) levels to rule out the diagnosis of neuroblastoma. Thirty-seven of these patients had elevated HVA and/or VMA levels, and neuroblastoma was subsequently diagnosed. In three additional patients with negative test results (normal HVA and VMA levels), tumors were subsequently diagnosed (false-negative rate of 7.5%). Ten percent of the patients with neuroblastoma had normal HVA and 27.5% had normal VMA levels at the time of diagnosis. Only one patient (2.5%) with neuroblastoma had elevated VMA levels in the presence of normal HVA levels. More than 60% of the patients with neuroblastoma had urinary HVA and/or VMA levels higher than twice the upper limit of normal. No false-positive results were encountered. Age and stage distributions of the patients are shown, and the significance of the results is discussed.


The Lancet ◽  
1972 ◽  
Vol 299 (7764) ◽  
pp. 1341-1342 ◽  
Author(s):  
RonaldP. Ng ◽  
T.K. Chan ◽  
D. Todd

Biosensors ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 479
Author(s):  
Soumi Sukla ◽  
Prasenjit Mondal ◽  
Subhajit Biswas ◽  
Surajit Ghosh

Detecting dengue virus (DENV) infection in patients as early as possible makes the disease management convenient. Conventionally, DENV infection is diagnosed by ELISA-based methods, but sensitivity and specificity are major concerns. Reverse-transcription-PCR (RT-PCR)-based detection confirms the presence of DENV RNA; however, it is expensive, time-consuming, and skilled personnel are required. A fluorescence-based detection system that detects DENV RNA in patient’s serum directly, without any nucleic acid amplification step, has been developed. The method uses target-specific complementary sequence in the molecular beacon, which would specifically bind to the DENV RNA. The molecular beacons are approximately 40 bases long hairpin structures, with a fluorophore-quencher system attached at the terminal ends of the stem. These probes are biotinylated in the stem region, so that they can be immobilized on the streptavidin-tagged magnetic beads. These magnetic beads, coupled with biotinylated molecular beacons, are used for the detection of the target RNA in the serum by incubating the mixture. After incubation, beads are separated and re-suspended in a buffer. The measurement of fluorescence is taken in fluorometer after 15 min incubation at 50 °C. The whole work is carried out in a single tube. This rapid method can precisely detect dengue RNA within two hours, confirming ongoing DENV replication in the patient.


PLoS ONE ◽  
2021 ◽  
Vol 16 (6) ◽  
pp. e0252757
Author(s):  
Miyuki Mizoguchi ◽  
Sohei Harada ◽  
Koh Okamoto ◽  
Yoshimi Higurashi ◽  
Mahoko Ikeda ◽  
...  

Background A number of nucleic acid amplification tests (NAATs) for SARS-CoV-2 with different reagents have been approved for clinical use in Japan. These include research kits approved under emergency use authorization through simplified process to stabilize the supply of the reagents. Although these research kits have been increasingly used in clinical practice, limited data is available for the diagnostic performance in clinical settings. Methods We compared sensitivity, specificity, and cycle threshold (Ct) values obtained by NAATs using 10 kits approved in Japan including eight kits those receiving emergency use authorization using 69 frozen-stored clinical samples including 23 positive samples with various Ct values and 46 negative samples. Results Viral copy number of the frozen-stored samples determined with LightMix E-gene test ranged from 0.6 to 84521.1 copies/μL. While no false-positive results were obtained by any of these tests (specificity: 100% [95% CI, 88.9%-100%]), sensitivity of the nine tests ranged from 68.2% [95% CI, 45.1%-86.1%] to 95.5% [95% CI, 77.2%-99.9%] using LightMix E-gene test as the gold standard. All tests showed positive results for all samples with ≥100 copies/μL. Significant difference of Ct values even among tests amplifying the same genetic region (N1-CDC, N2) was also observed. Conclusion Difference in the diagnostic performance was observed among NAATs approved in Japan. Regarding diagnostic kits for emerging infectious diseases, a system is needed to ensure both rapidity of reagent supply and accuracy of diagnosis. Ct values, which are sometimes regarded as a marker of infectivity, are not interchangeable when obtained by different assays.


2021 ◽  
Vol 15 (10) ◽  
pp. 3356-3358
Author(s):  
Ambreen Fatima ◽  
Nidda Yaseen ◽  
Amna Fareed ◽  
Kashif Ali Samin ◽  
Shumaela Kanwal ◽  
...  

Background and Aim: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) rapid emergence postured significant challenges on the health system in recent years. The early detection of cases is thought to be critical in preventing this pandemic by coronavirus disease (COVID-19), especially important in the obstetrical population due to theirs numerous interactions with another parturient when hospitalized for delivery. Therefore, the present study aimed to assess the COVID antigen test performance in COVID-positive obstetrics patients. Materials and Methods: This cross-sectional study was conducted on 1296 Covid-19 asymptomatic women admitted to the Obstetrics and Gynaecology Department of Muhammad Teaching Hospital & Medical College, Peshawar and Fauji Foundation Hospital, Rawalpindi for the duration of six months from February 2021 to July 2021. Antigen-based test rapid diagnostic test (RDT) was used for screening out COVID-19 positive obstetrics patients or women through nasopharyngeal swabs. Women with negative rapid antigen test results were confirmed with RT-polymers chain reaction test of nucleic acid amplification tests (NAAT). Ethical approval and informed consent were taken from the hospital ethical committee and each individual respectively. All the known positive COVID-19 patients during admission were excluded. SPSS version 24 was used for data analysis. Results: The overall prevalence of rapid antigen-positive tested patients was 13.2% (171/1296). The prevalence of positive tested women through rapid antigen test, Nucleic Acid Amplification Test (NAAT), and RT-PCR were 27 (2.1%), 51 (3.9%), and 93 (7.2%) respectively. Of the total 1296 rapid antigen tests, 27 were positive, and the false-negative confirmed positive by NAAT was 144.Thus the sensitivity of the rapid antigen test was 15.8% and the negative predictive value was 93.7%. Of the total 298 Nucleic Acid Amplification Tested had sensitivity and negative predictive value of 89.6% and 99.06% respectively. RT-PCR was carried out on 972 patients, positive diagnosed cases were 36 while 15 were initially negative and were positive with the test was repeated. The sensitivity and negative predictive value was 71.45% and 95.8% respectively. Conclusion: Our study found that Ag-RDT plays a significant role in SARS-CoV-2 early detection in infected individuals, with high specificity and sensitivity to disease infectious stage, whether symptomatic or asymptomatic, and can be used as a decision supported tool. Early detection of COVID-19 status in women admitted for delivery could benefit neonatal protection care. Keywords: Covid-19; Rapid antigen test; RT-PCR test


PEDIATRICS ◽  
1996 ◽  
Vol 98 (1) ◽  
pp. 41-44
Author(s):  
Judy G. Saslow ◽  
Ernest M. Post ◽  
Carol A. Southard

Objective. As neonatal discharge before 24 hours of life becomes commonplace, the rejection of congenital hypothyroidism (CH) screening specimens obtained too early has created the need for numerous additional tests. We sought to determine whether the specimens obtained before 24 hours could be used safely. Methods. During a 31-day period we measured thyrotropin in all thyroid-screening specimens that had been obtained before 24 hours. We also examined the early specimens from every infant diagnosed in New Jersey with CH during 1993 or 1994. Results. Among the 663 specimens, those obtained at or before 12 hours and those from infants with birth weights less than 2500 g had too many low thyroxine results to be useful. Among the 515 specimens obtained at more than 12 to 24 hours from newborns weighing 2500 g or more, 37 (7%) had low thyroxine levels and 12 (2.3%) had thyrotropin levels of 20 µIU/mL (mU/L) or higher. Four hundred seventy-one of the 515 infants had subsequent specimens obtained at more than 24 hours, and none of the results were abnormal. There was no child weighing more than or equal to 2500 g who was diagnosed with CH in 1993 and 1994 whose specimen obtained at 24 hours or less was normal. Conclusions. Accepting specimens obtained at more than 12 to 24 hours from infants weighing 2500 g or more would have resulted in more than the usual number of false-positive results but no false-negative results. This would have decreased the requests for additional specimens by more than 90%.


Sign in / Sign up

Export Citation Format

Share Document