Relative Sensitivity of Escherichia coli O157 Detection from Bovine Feces and Rectoanal Mucosal Swabs

2014 ◽  
Vol 77 (6) ◽  
pp. 972-976 ◽  
Author(s):  
K. J. WILLIAMS ◽  
M. P. WARD ◽  
O. DHUNGYEL ◽  
L. VAN BREDA

The need to quantify the potential human health risk posed by the bovine reservoir of Escherichia coli O157 has led to a wealth of prevalence studies and improvements in detection methods over the last two decades. Rectoanal mucosal swabs have been used for the detection of E. coli O157 fecal shedding, colonized animals, and those predisposed to super shedding. We conducted a longitudinal study to compare the detection of E. coli O157 from feces and rectoanal mucosal swabs (RAMS) from a cohort of dairy heifers. We collected 820 samples that were tested by immunomagnetic separation of both feces and RAMS. Of these, 132 were detected as positive for E. coli O157 from both samples, 66 were detected as positive from RAMS only, and 117 were detected as positive from feces only. The difference in results between the two sample types was statistically significant (P < 0.001). The relative sensitivities of detection by immunomagnetic separation were 53% (confidence interval, 46.6 to 59.3) from RAMS and 67% (confidence interval, 59.6 to 73.1) from fecal samples. No association between long-term shedding (P = 0.685) or super shedding (P = 0.526) and detection by RAMS only was observed.

2007 ◽  
Vol 70 (5) ◽  
pp. 1072-1075 ◽  
Author(s):  
T. P. STEPHENS ◽  
G. H. LONERAGAN ◽  
W. E. CHANEY ◽  
L. A. BRANHAM ◽  
M. M. BRASHEARS

A method to validate enumeration of Escherichia coli O157 in fecal samples from feedlot cattle was developed in these studies. Due to background flora, bovine fecal sample enumeration cannot be performed by simple direct plating techniques. Known quantities of E. coli O157:H7 were inoculated into feces, and populations were determined by direct plating of the cocktail (studies 1, 2, and 3) and manure and cocktail (studies 4 and 5) mixtures and compared with a most-probable-number (MPN)–immunomagnetic separation (IMS) method. The three-tube MPN combined preenrichment in gram-negative broth with confirmation using IMS. Five separate enumeration studies (study 1, sterile feces inoculated with 102 E. coli O157:H7 per g; study 2, nonsterile feces inoculated with 103 E. coli O157:H7 per g; study 3, nonsterile feces inoculated with 101 E. coli O157:H7 per g; study 4, sterile feces inoculated with 104 streptomycin-resistant E. coli O157:H7 per g; and study 5, sterile feces inoculated with 102 streptomycin-resistant E. coli O157:H7 per g) were conducted. These studies were performed to determine the precision, accuracy, and specificity at low and high levels of pathogen contamination in feces, using direct plating compared with the MPN-IMS methodology tested. There was an overall difference (P < 0.01) between direct plating and MPN-IMS methodologies, but this difference was biologically negligible due to the difference in least-squares means (0.29 ± 0.10) being so low. The direct plating and MPN-IMS methods were correlated (r = 0.93). These results suggest that using the MPN-IMS procedures is an effective method of estimating E. coli O157 populations in naturally infected bovine fecal samples.


2005 ◽  
Vol 68 (8) ◽  
pp. 1566-1574 ◽  
Author(s):  
TERRANCE M. ARTHUR ◽  
JOSEPH M. BOSILEVAC ◽  
XIANGWU NOU ◽  
MOHAMMAD KOOHMARAIE

Currently, several beef processors employ test-and-hold systems for increased quality control of ground beef. In such programs, each lot of product must be tested and found negative for Escherichia coli O157:H7 prior to release of the product into commerce. Optimization of three testing attributes (detection time, specificity, and sensitivity) is critical to the success of such strategies. Because ground beef is a highly perishable product, the testing methodology used must be as rapid as possible. The test also must have a low false-positive result rate so product is not needlessly discarded. False-negative results cannot be tolerated because they would allow contaminated product to be released and potentially cause disease. In this study, two culture-based and three PCR-based methods for detecting E. coli O157:H7 in ground beef were compared for their abilities to meet the above criteria. Ground beef samples were individually spiked with five genetically distinct strains of E. coli O157: H7 at concentrations of 17 and 1.7 CFU/65 g and then subjected to the various testing methodologies. There was no difference (P > 0.05) in the abilities of the PCR-based methods to detect E. coli O157:H7 inoculated in ground beef at 1.7 CFU/65 g. The culture-based systems detected more positive samples than did the PCR-based systems, but the detection times (21 to 48 h) were at least 9 h longer than those for the PCR-based methods (7.5 to 12 h). Ground beef samples were also spiked with potentially cross-reactive strains. The PCR-based systems that employed an immunomagnetic separation step prior to detection produced fewer false-positive results.


2006 ◽  
Vol 69 (12) ◽  
pp. 2851-2855 ◽  
Author(s):  
A. ECHEVERRY ◽  
G. H. LONERAGAN ◽  
M. M. BRASHEARS

Although Escherichia coli O157:H7 prevalence estimates in cattle have increased over time due to improvements in detection methods, fecal sample transport conditions from farm to microbiological laboratories for further analysis may be a factor for prevalence underestimation. The objective of this study was to compare and determine the survival characteristics of E. coli O157:H7 in bovine feces under various storage conditions that could be encountered during transport. Fecal pats were inoculated with a four-strain cocktail of antibiotic-resistant E. coli O157:H7 to contain ∼1 × 105 CFU/g. Inoculated and control samples were taken after 0, 24, 48, 120, and 168 h at each storage temperature and examined for presence and numbers of E. coli O157:H7. Each sample was subdivided and placed at each of the four following temperatures: 37, 23, 4.4°C, and in a plastic cooler with refrigerant packs (0, 4, 4, 21, and 23°C at five sampling times, respectively) to simulate transportation conditions. A statistically significant decrease in the population of the pathogen was observed after 48 h in samples held at 37°C(P < 0.01) and after 168 h at 4.4°C(P = 0.02). At 37°C, E. coli O157:H7 was not detected after 48 h, either by direct plating (P < 0.01) or by immunomagnetic separation. Overall, the results of this study showed that E. coli O157:H7 survived without significant detriment in bovine fecal material inside the cooler for up to 168 h. These results indicate that shipment and storage under these conditions before microbiological analysis would be acceptable and should not affect pathogen detection.


2006 ◽  
Vol 69 (5) ◽  
pp. 1007-1011 ◽  
Author(s):  
MICHAEL N. GUERINI ◽  
TERRANCE M. ARTHUR ◽  
STEVEN D. SHACKELFORD ◽  
MOHAMMAD KOOHMARAIE

Since the mid-1990s, the beef industry has used a process called test and hold, wherein beef trim and ground beef are tested to keep products contaminated with Escherichia coli O157:H7 out of commerce. Current O157:H7 detection methods rely on a threshold level of bacterial growth for detection, which is dependent on the growth medium used. Twelve media were examined for growth and doubling time: buffered peptone water (BPW), SOC (which contains tryptone, yeast extract, KCl, MgCl2, and glucose), buffered peptone water plus SOC (BPW-SOC), Bacto-NZYM, RapidChek E. coli O157:H7 medium, BioControl EHEC8 culture medium, Neogen Reveal for E. coli O157:H7—Eight Hour medium (Neogen Reveal 8), BAX System medium for E. coli O157:H7 (BAX), BAX System medium for E. coli O157:H7 MP (BAX-MP), modified E. coli broth, nutrient medium, and tryptic soy broth (TSB). All media were tested at 37 or 42°C under static or shaking conditions. The eight media with the highest total CFU per milliliter and most rapid doubling times were BPW-SOC, NZYM, RapidChek, EHEC8, Neogen Reveal 8, BAX, BAX-MP, and TSB. The ability of these eight media to enrich E. coli O157:H7 in ground beef was further evaluated through time-course experiments using immunomagnetic separation. Of these media, TSB was the easiest to prepare, had a wide application base, and was the least expensive. In the test-and-hold process, the normal ratio of medium to product is 1:10. In this study, a 1:3 ratio worked as well as a 1:10 ratio. Processors using test-and-hold procedures could use 1 liter of TSB to enrich for E. coli O157:H7 in a 375-g sample instead of the usual 3.375 liters, thus saving reagents, time, and labor while maintaining accuracy.


2007 ◽  
Vol 70 (10) ◽  
pp. 2230-2234 ◽  
Author(s):  
T. W. THOMPSON ◽  
T. P. STEPHENS ◽  
G. H. LONERAGAN ◽  
M. F. MILLER ◽  
M. M. BRASHEARS

Rapid enzyme-linked immunosorbent assays (ELISAs) are approved for detection of Escherichia coli O157 in beef products. However, these kits have also been used in the industry to detect this pathogen on hides or in feces of cattle, although this use has not been validated. The objective of this study was to compare commercially available ELISAs (E. coli Now, Reveal, and VIP) with immunomagnetic separation along with selective media to detect E. coli O157 on hides, in feces, and in medium- and low-level-inoculated ground beef and carcasses (simulated by using briskets) samples. Naturally infected hide and fecal samples were subjected to both the immunomagnetic separation method and ELISAs for the detection of E. coli O157. Additionally, E. coli O157 inoculated and noninoculated ground beef and beef briskets were used to simulate meat and carcass samples. When comparing the detection results from the ELISAs (E. coli Now, Reveal, and VIP) to the immunomagnetic separation method, poor agreement was observed for fecal samples (kappa = 0.10, 0.02, and 0.03 for E. coli Now, Reveal, and VIP, respectively), and fair-to-moderate agreement was observed for hide samples (kappa = 0.30, 0.51, and 0.29 for E. coli Now, Reveal, and VIP, respectively). However, there was near-perfect agreement between the immunomagnetic separation method and ELISAs for ground beef (kappa = 1, 1, and 0.80 for E. coli Now, Reveal, and VIP, respectively) and brisket (kappa = 1, 1, and 1 for E. coli Now, Reveal, and VIP, respectively) samples. Assuming immunomagnetic separation is the best available method, these data suggest that the ELISAs are not useful in detecting E. coli O157 from hide or fecal samples. However, when ELISAs are used on ground beef and beef brisket samples they can be used with a high degree of confidence.


1999 ◽  
Vol 65 (4) ◽  
pp. 1397-1404 ◽  
Author(s):  
Lawrence Goodridge ◽  
Jinru Chen ◽  
Mansel Griffiths

ABSTRACT In this paper we describe evaluation and characterization of a novel assay that combines immunomagnetic separation and a fluorescently stained bacteriophage for detection of Escherichia coliO157:H7 in broth. When it was combined with flow cytometry, the fluorescent-bacteriophage assay (FBA) was capable of detecting 104 cells/ml. A modified direct epifluorescent-filter technique (DEFT) was employed in an attempt to estimate bacterial concentrations. Using regression analysis, we calculated that the lower detection limit was between 102 and 103cells/ml; however, the modified DEFT was found to be an unreliable method for determining bacterial concentrations. The results of this study show that the FBA, when combined with flow cytometry, is a sensitive technique for presumptive detection of E. coliO157:H7 in broth cultures.


2011 ◽  
Vol 74 (1) ◽  
pp. 6-12 ◽  
Author(s):  
F. SAVOYE ◽  
P. FENG ◽  
C. ROZAND ◽  
M. BOUVIER ◽  
A. GLEIZAL ◽  
...  

Enterohemorrhagic Escherichia coli O157:H7 is an important pathogen associated with infections caused by consumption of undercooked raw meat. Sensitive and rapid detection methods for E. coli O157:H7 are essential for the meat industry to ensure a safe meat supply. This study was conducted to compare the sensitivity of the VIDAS ultraperformance E. coli test (ECPT UP) with a noncommercial real-time (RT) PCR method and the U.S. Department of Agriculture, Food Safety and Inspection Service (USDA-FSIS) reference method for detecting E. coli O157:H7 in raw ground beef. Optimal enrichment times and the efficacy of testing different types of raw meat, either as individual samples (25 g) or as composites (375 g), were examined. For 25-g samples of each type of raw ground beef tested, 6 h of enrichment was sufficient for both the VIDAS ECPT UP and RT-PCR methods, but for 375-g samples, 24 h of enrichment was required. Both the VIDAS ECPT UP and RT-PCR methods produced results similar to those obtained with the USDA-FSIS reference method after 18 to 24 h of enrichment. The primer specificity of the RT-PCR assay and the highly specific phage ligand used in the VIDAS ECPT UP for target recognition enabled the detection of low levels of E. coli O157:H7 in 25 g of various types of raw ground beef. The tests also allowed the detection of E. coli O157:H7 in composite raw ground beef and trimmings in samples of up to 375 g.


2015 ◽  
Vol 78 (2) ◽  
pp. 264-272 ◽  
Author(s):  
CLAUDIA NARVÁEZ-BRAVO ◽  
ALEJANDRO ECHEVERRY ◽  
MARKUS F. MILLER ◽  
ARGENIS RODAS-GONZÁLEZ ◽  
M. TODD BRASHEARS ◽  
...  

The objective of the study was to characterize virulence genes and subtype Escherichia coli O157:H7 and O157:H(−) isolates obtained from a vertically integrated feedlot slaughter plant in Mexico. A total of 1,695 samples were collected from feedlots, holding pens, colon contents, hides, and carcasses. E. coli O157:H7 detection and confirmation was carried out using conventional microbiology techniques, immunomagnetic separation, latex agglutination, and the BAX system. A total of 97 E. coli O157 strains were recovered and screened for key virulence and metabolic genes using multiplex and conventional PCR. Eighty-eight (91.72%) of the strains carried stx2, eae, and ehxA genes. Ten isolates (8.25%) were atypical sorbitol-fermenting strains, and nine were negative for the flicH7 gene and lacked eae, stx1, stx2, and ehxA. One sorbitol-positive strain carried stx2, eae, tir, toxB, and iha genes but was negative for stx1 and ehxA. Pulsed-field gel electrophoresis (PFGE) analysis yielded 49 different PFGE subtypes, showing a high genetic diversity; however, the majority of the typical isolates were closely related (80 to 90% cutoff). Atypical O157 isolates were not closely related within them or to typical E. coli O157:H7 isolates. Identical PFGE subtypes were found in samples obtained from colon contents, feedlots, holding pens, and carcasses. Isolation of a sorbitol-fermenting E. coli O157 positive for a number of virulence genes is a novel finding in Mexico. These data showed that genetically similar strains of E. coli O157:H7 can be found at various stages of beef production and highlights the importance of preventing cross-contamination at the pre- and postharvest stages of processing.


2002 ◽  
Vol 65 (7) ◽  
pp. 1172-1176 ◽  
Author(s):  
S. M. AVERY ◽  
A. SMALL ◽  
C.-A. REID ◽  
S. BUNCIC

Contamination of the brisket areas of the hides of healthy adult cattle with Shiga toxin–producing Escherichia coli O157 at slaughter in England was studied. In total, 73 cattle consignments comprising 584 animals delivered to one abattoir over 3 days during 1 week in July 2001 were studied: 26 cattle consignments arriving on Monday, 32 consignments arriving on Wednesday, and 15 consignments arriving on Friday. Consignment sizes ranged from 1 to 23 animals, with a mean consignment size of 8. The hide of the first animal to be slaughtered in each consignment was sampled by using a sponge swab moistened with 0.85% saline to rub an unmeasured brisket (ventral) area (ca. 30 by 30 cm). The process of isolating E. coli O157 from the swabs consisted of enrichment, screening with immunoprecipitation assay kits, and immunomagnetic separation. E. coli O157 was found on 24 of 73 (32.9%) cattle hides examined, and 21 of these 24 isolates produced Shiga toxins. The 24 E. coli O157 isolates produced six different pulsed-field gel electrophoresis profiles, and 18 (75%) of the isolates were of one prevalent clone. The high prevalence of one E. coli O157 clone on the hides of cattle at slaughter could be due to a high prevalence of that clone on the 18 farms involved (not investigated in the current study), in the postfarm transport or lairage environments, or both. Since the lairage environment, but not the farm of origin or the postfarm transport vehicle, was a factor common to all 18 cattle consignments, it could have played an important role in spreading the prevalent E. coli O157 clone to the cattle hides. Lairage pen floors and the stunning box floor were identified as the most probable sites along the unloading-to-slaughter route at which the brisket areas of cattle hides could become contaminated.


2020 ◽  
Vol 83 (8) ◽  
pp. 1444-1462 ◽  
Author(s):  
GENEVIÈVE COULOMBE ◽  
ANGELA CATFORD ◽  
AMALIA MARTINEZ-PEREZ ◽  
ENRICO BUENAVENTURA

ABSTRACT Foodborne diseases are a major cause of illness in Canada. One of the main pathogens causing cases and outbreaks of foodborne illness in Canada is Escherichia coli O157:H7. From 2008 to 2018, 11 outbreaks of E. coli O157:H7 infection in Canada were linked to leafy greens, including 7 (63.6%) linked to romaine lettuce, 2 (18.2%) linked to iceberg lettuce, and 2 (18.2%) linked to other or unspecified types of leafy greens. The consumption of lettuce in Canada, the behavior of E. coli O157:H7 on lettuce leaves, and the production practices used for romaine and iceberg lettuce do not seem to explain why a higher number of outbreaks of E. coli O157:H7 infection were linked to romaine than to iceberg lettuce. However, the difference in the shape of iceberg and romaine lettuce heads could be an important factor. Among the seven outbreaks linked to romaine lettuce in Canada between 2008 and 2018, an eastern distribution of cases was observed. Cases from western provinces were reported only twice. The consumption of romaine and iceberg lettuce by the Canadian population does not seem to explain the eastern distribution of cases observed, but the commercial distribution, travel distances, and the storage practices used for lettuce may be important factors. In the past 10 years, the majority of the outbreaks of E. coli O157:H7 infection linked to romaine lettuce occurred during the spring (March to June) and fall (September to December). The timing of these outbreaks may be explained by the availability of lettuce in Canada, the growing region transition periods in the United States, and the seasonality in the prevalence of E. coli O157:H7. The consumption of romaine lettuce by the Canadian population does not explain the timing of the outbreaks observed. HIGHLIGHTS


Sign in / Sign up

Export Citation Format

Share Document