scholarly journals Chromium and cadmium removal from synthetic wastewater by Electrocoagulation process

2020 ◽  
Vol 9 (2) ◽  
pp. 375-382

Electrocoagulation (EC) is one of the efficient electrochemical approaches for industrial wastewater treatment. The present work aims to reach optimum conditions for achieving simultaneous removal of chromium and cadmium ions from synthetic wastewater by EC through assessment of different parameters like electrodes material, electrode configuration, initial pH, current density, initial temperature, and initial contaminate concentration. In addition, a comparison between chemical coagulation and EC efficiency for Chromium and cadmium removal was presented. Results showed that the (Fe-Al), an anode and cathode, achieved better removal efficiency than other electrodes configurations (Fe-Fe / Al-Fe / Al- Al). Also, the increase of initial temperature and current density enhanced the removal efficiency. In contrast, the increase in the initial concentration reduced the removal efficiency. The complete removal of Chromium achieved through the use of Fe-Al electrodes and current density was 12.50 mA/cm2 with solution pH of 5.8, temperature was 25oC and an initial concentration of 280 mg/L. On the other hand, Cadmium’s complete removal was achieved through the use of Fe-Allectrodes, at pH of 5.8, applied current 1.4 A and 60oC. Therefore, EC was proved to be better approach than conventional coagulation in case of treatment of wastewater containing different types of heavy metals ions with high initial concentrations.

2021 ◽  
Vol 10 (3) ◽  
pp. 415-424
Author(s):  
Aji Prasetyaningrum ◽  
Dessy Ariyanti ◽  
Widayat Widayat ◽  
Bakti Jos

Electroplating wastewater contains high amount of heavy metals that can cause serious problems to humans and the environment. Therefore, it is necessary to remove heavy metals from electroplating wastewater. The aim of this research was to examine the electrocoagulation (EC) process for removing the copper (Cu) and lead (Pb) ions from wastewater using aluminum electrodes. It also analyzes the removal efficiency and energy requirement rate of the EC method for heavy metals removal from wastewater. Regarding this matter, the operational parameters of the EC process were varied, including time (20−40 min), current density (40−80 A/m2), pH (3−11), and initial concentration of heavy metals. The concentration of heavy metals ions was analyzed using the atomic absorption spectroscopy (AAS) method. The results showed that the concentration of lead and copper ions decreased with the increase in EC time. The current density was observed as a notable parameter. High current density has an effect on increasing energy consumption. On the other hand, the performance of the electrocoagulation process decreased at low pH. The higher initial concentration of heavy metals resulted in higher removal efficiency than the lower concentration. The removal efficiency of copper and lead ions was 89.88% and 98.76%, respectively, at 40 min with electrocoagulation treatment of 80 A/m2 current density and pH 9. At this condition, the specific amounts of dissolved electrodes were 0.2201 kg/m3, and the energy consumption was 21.6 kWh/m3. The kinetic study showed that the removal of the ions follows the first-order model.


2019 ◽  
Vol 26 (1) ◽  
pp. 24-34 ◽  
Author(s):  
Mohammed Alameen Salem ◽  
Najwa Majeed

Cadmium is one of the heavy metal found in the wastewater of many industries. The electrocoagulation offers many advantages for the removal of cadmium over other methods. So the removal of cadmium from wastewater by using electrocoagulation was studied to investigate the effect of operating parameters on the removal efficiency. The studied parameters were the initial pH, initial concentration, and applied voltage. The study experiments were conducted in a batch reactor with  with two pairs of aluminum electrodes with dimension  and 2mm in thick with 1.5 cm space between them. The optimum removal was obtained at pH =7, initial concentration = 50 mg/L, and applied voltage = 20 V and it was 90%.


2017 ◽  
Vol 2017 ◽  
pp. 1-10 ◽  
Author(s):  
Zhitao Han ◽  
Bojun Liu ◽  
Shaolong Yang ◽  
Xinxiang Pan ◽  
Zhijun Yan

The experiments were performed in a lab-scale countercurrent spraying reactor to study the NOxremoval from simulated gas stream by cyclic scrubbing using NaClO solution. The effects of NaClO concentration, initial solution pH, coexisting gases (5% CO2and 13% O2), NOxconcentration, SO2concentration, and absorbent temperature on NOxremoval efficiency were investigated in regard to marine exhaust gas. When NaClO concentration was higher than 0.05 M and initial solution pH was below 8, NOxremoval efficiency was relatively stable and it was higher than 60%. The coexisting CO2(5%) had little effect on NOxremoval efficiency, but the outlet CO2concentration decreased slowly with the initial pH increasing from 6 to 8. A complete removal of SO2and NO could be achieved simultaneously at 293 K, initial pH of 6, and NaClO concentration of 0.05 M, while the outlet NO2concentration increased slightly with the increase of inlet SO2concentration. NOxremoval efficiency increased slightly with the increase of absorbent temperature. The relevant reaction mechanisms for the oxidation and absorption of NO with NaClO were also discussed. The results indicated that it was of great potential for NOxremoval from marine exhaust gas by wet scrubbing using NaClO solution.


2014 ◽  
Vol 15 ◽  
pp. 89-93 ◽  
Author(s):  
R Ulambayar ◽  
J Oyuntsetseg ◽  
A Tsiiregzen ◽  
D Bayaraa

Trivalent chromium (Cr3+) removal from aqueous solution  by electrocoagulation using iron electrodes material was investigated in this paper. Effects of current density, initial concentration of Cr 3+, operating time,  pH, electrode distance, and operating cost have been investigated. At higher current density and solution pH, remarkable removal of Cr3+ was observed. Experiments have been show that the maximum removal percentage of the Cr3+ 99.89 % was at initial concentration 1000mg/L,  current density 9.34mA/cm2 and reaction time 1 hours. Energy consumption was calculated  for Cr3+ removal at different time. The method is observed to be very effective in the removal Cr3+ ion from aqueous solution. Electrocoagulation process need simple equipment, designable any size, use any chemical substances and low operating cost.DOI: http://doi.dx.org/10.5564/mjc.v15i0.330 Mongolian Journal of Chemistry 15 (41), 2014, p89-93


2016 ◽  
Vol 73 (11) ◽  
pp. 2704-2712 ◽  
Author(s):  
Mohammed J. K. Bashir ◽  
Tham Mau Han ◽  
Lim Jun Wei ◽  
Ng Choon Aun ◽  
Salem S. Abu Amr

As the ponding system used to treat palm oil mill effluent (POME) frequently fails to satisfy the discharge standard in Malaysia, the present study aimed to resolve this problem using an optimized electrocoagulation process. Thus, a central composite design (CCD) module in response surface methodology was employed to optimize the interactions of process variables, namely current density, contact time and initial pH targeted on maximum removal of chemical oxygen demand (COD), colour and turbidity with satisfactory pH of discharge POME. The batch study was initially designed by CCD and statistical models of responses were subsequently derived to indicate the significant terms of interactive process variables. All models were verified by analysis of variance showing model significances with Prob > F < 0.01. The optimum performance was obtained at the current density of 56 mA/cm2, contact time of 65 min and initial pH of 4.5, rendering complete removal of colour and turbidity with COD removal of 75.4%. The pH of post-treated POME of 7.6 was achieved, which is suitable for direct discharge. These predicted outputs were subsequently confirmed by insignificant standard deviation readings between predicted and actual values. This optimum condition also permitted the simultaneous removal of NH3-N, and various metal ions, signifying the superiority of the electrocoagulation process optimized by CCD.


2011 ◽  
Vol 6 (1) ◽  
Author(s):  
M. Behbahani ◽  
M.R. Alavi Moghaddam ◽  
M. Arami

The aim of this study is to examine the effect of operational parameters on fluoride removal using electrocoagulation method. For this purpose, various operational parameters including initial pH, initial fluoride concentration, applied current, reaction time, electrode connection mode, anode material, electrolyte salt, electrolyte concentration, number of electrodes and interelectrode distance were investigated. The highest defluoridation efficiency achieved at initial pH 6. In the case of initial fluoride concentration, maximum removal efficiency (98.5%) obtained at concentration of 25mg/l. The increase of applied current and reaction time improved defluoridation efficiency up to 99%. The difference of fluoride removal efficiencies between monopolar and bipolar series and monopolar parallel were significant, especially at reaction time of 5 min. When aluminum used as anode material, higher removal efficiency (98.5%) achieved compared to that of iron anode (67.7%). The best electrolyte salt was NaCl with the maximum defluoridation efficiency of 98.5% compared to KNO3 and Na2SO4. The increase of NaCl had no effect on defluoridation efficiency. Number of electrodes had little effect on the amounts of Al3+ ions released in the solution and as a result defluoridation efficiency. Almost the same fluoride removal efficiency obtained for different interelectrode distances.


2018 ◽  
Vol 19 (4) ◽  
pp. 1066-1072
Author(s):  
Q. H. Jin ◽  
C. Y. Cui ◽  
H. Y. Chen ◽  
Y. Wang ◽  
J. F. Geng ◽  
...  

Abstract Adsorption (ADS) and dielectrophoresis (DEP) techniques were combined (ADS/DEP) to efficiently remove As(V) in industrial wastewater. Fly ash, activated carbon, corncob and plant ash were tested to determine the best adsorbent by their adsorption capacity. Plant ash showed the highest adsorption capacity compared with the others. Different parameters such as solution pH and adsorbent dose were explored. The maximum As(V) removal efficiency was 91.4% at the optimized conditions (pH 9.0, adsorbent dose 5 g/L) when the initial concentration of As(V) was 15 mg/L. With the ADS/DEP technique, the plant ash particles with adsorbed As(V) were trapped on the electrodes in a DEP device. The ADS/DEP process could increase the removal efficiency of As(V) to 94.7% at 14 V even when the initial concentration of As(V) was 15 mg/L. And the residual concentration of As(V) decreased to 0.34 mg/L after two series of the ADS/DEP process. The adsorbents before and after DEP were examined by scanning electron microscope (SEM) and energy dispersive X-ray (EDX) analysis. After the DEP process, the weight percentage of As(V) on the adsorbent surface increased to 0.96% from 0.5%. The ADS/DEP process could be a new efficient way to remove arsenic pollutant at high concentrations.


2019 ◽  
Vol 84 (7) ◽  
pp. 713-727 ◽  
Author(s):  
Jiteng Wan ◽  
Chunji Jin ◽  
Banghai Liu ◽  
Zonglian She ◽  
Mengchun Gao ◽  
...  

Even in a trace amounts, the presence of antibiotics in aqueous solution is getting more and more attention. Accordingly, appropriate technologies are needed to efficiently remove these compounds from aqueous environments. In this study, we have examined the electrochemical oxidation (EO) of sulfamethoxazole (SMX) on a Co modified PbO2 electrode. The process of EO of SMX in aqueous solution followed the pseudo-first-order kinetics, and the removal efficiency of SMX reached the maximum value of 95.1 % within 60 min. The effects of major factors on SMX oxidation kinetics were studied in detail by single-factor experiments, namely current density (1?20 mA cm-2), solution pH value (2?10), initial concentration of SMX (10?500 mg L-1) and concentration of electrolytes (0.05?0.4 mol L-1). An artificial neural network (ANN) model was used to simulate this EO process. Based on the obtained model, particle swarm optimization (PSO) was used to optimize the operating parameters. The maximum removal efficiency of SMX was obtained at the optimized conditions (e.g., current density of 12.37 mA cm-2, initial pH value of 4.78, initial SMX concentration of 74.45 mg L-1, electrolyte concentration of 0.24 mol L-1 and electrolysis time of 51.49 min). The validation results indicated that this method can ideally be used to optimize the related parameters and predict the anticipated results with acceptable accuracy.


2004 ◽  
Vol 49 (5-6) ◽  
pp. 341-354 ◽  
Author(s):  
C.M. Lee ◽  
C.C. Wang

The aim of this study is to isolate denitrifying bacteria utilizing ɛ-caprolactam as the substrate, from a polyacrylonitrile fibre manufactured wastewater treatment system. The aim is also to compare the performance of PAN (polyacrylonitrile) mixed bacteria cultures acclimated to ɛ-caprolactam and isolated pure strain for treating different initial e-caprolactam concentrations from synthetic wastewater under anoxic conditions. The result showed that the PAN mixed bacteria cultures acclimated to e-caprolactam could utilize 1538.5 mg/l of ɛ-caprolactam as a substrate for denitrification. Sufficient time and about 2200 mg/l of nitrate were necessary for the complete ɛ-caprolactam removal. Paracoccus thiophilus was isolated from the polyacrylonitrile fibre manufactured wastewater treatment system and it could utilize 1722.5 mg/l of ɛ-caprolactam as a substrate for denitrification. About 3500 mg/l of nitrate was necessary for the complete removal of ɛ-caprolactam. When the initial ɛ-caprolactam concentration was below 784.3 mg/l, the removal efficiency of ɛ-caprolactam by Paracoccus thiophilus was better than that for the PAN mixed bacteria cultures. The growth of Paracoccus thiophilus was better. However, when the initial ɛ-caprolactam concentration was as high as 1445.8 mg/l, both the ɛ-caprolactam removal efficiency by Paracoccus thiophilus and Paracoccus thiophilus specific growth rate were similar to the PAN mixed bacteria cultures.


2017 ◽  
Vol 19 (2) ◽  
pp. 67-71 ◽  
Author(s):  
Ha Manh Bui

Abstract The COD removal efficiency from an instant coffee processing wastewater using electrocoagulation was investigated. For this purpose, the response surface methodology was employed, using central composing design to optimize three of the most important operating variables, i.e., electrolysis time, current density and initial pH. The results based upon statistical analysis showed that the quadratic models for COD removal were significant at very low probability value (<0.0001) and high coefficient of determination (R2 = 0.9621) value. The statistical results also indicated that all the three variables and the interaction between initial pH and electrolysis time were significant on COD abatement. The maximum predicted COD removal using the response function reached 93.3% with electrolysis time of 10 min, current density of 108.3 A/m2 and initial pH of 7.0, respectively. The removal efficiency value was agreed well with the experimental value of COD removal (90.4%) under the optimum conditions.


Sign in / Sign up

Export Citation Format

Share Document