scholarly journals Sosialisasi Sistem Penerangan Listrik dan Perhitungan Tarif Listrik Tahun 2020 pada Pemuda Muhammadiyah Cabang Pulo Brayan Darat

2021 ◽  
Vol 1 (1) ◽  
pp. 104-108
Author(s):  
Abdullah Abdullah ◽  
Cholish Cholish ◽  
Moh. Zainul Haq ◽  
Ferdinan Rinaldo Tampubolon ◽  
Rischa Devita

The increasing use of electrical energy in society in 2020 is closely related to the pandemic problem that is occurring. Increased household activity causes a surge in energy in the household sector. This increase in energy consumption needs to be balanced by providing exposure to the utilization of existing electrical equipment in households. The lighting system give an important role in energy consumption in the household sector. The dedication carried out is by providing knowledge on the use of the lighting system, the rules in PUIL 2000 and the calculation of the Basic Electricity Tariff (TDL) in 2020. Submission of this will certainly increase public understanding of energy savings so that it can contribute to overcoming the problem of electricity devisit occur.

2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC


2018 ◽  
Vol 9 (1) ◽  
pp. 1-7
Author(s):  
Redaksi Tim Jurnal

PT PJB Muara Karang power plant is an industry with a large electrical energy consumption for auxiliary power. In ISO50001 itensitas Energy Consumption (IKE) is a great need to audit energy consumption. In the contract the company's performance also set a percentage of personal use should not exceed 6% of the electricity production. Currently Posentase usage of own consumption at power plant unit 5 is greater than the power plant unit 4. It is necessary for an energy audit for the usage of its own in order to decrease the percentage of personal use in the power plant 5 0.5% of the current conditions and find energy savings opportunities in the power plant unit 5.To analyze this problem using energy audits, analyzes the performance test method using "gate cycle" and testing the quality of the voltage source by using the power quality measurement analysis. Having found the equipment with the largest energy comsumtion fish bone tools used to find the main cause of this disorder.


Author(s):  
Frank J. Agraz ◽  
John Maneri

The continual rising cost of energy, existing outdated lighting technology, and inefficient lighting designs have given property owners the opportunity to improve their facilities by retrofitting their existing luminaires with an energy efficient lighting system. A lighting retrofit uses the existing electrical infrastructure to replace, relocate, or convert existing luminaires with the latest generation of cost-effective components. New lighting technology has emerged within the last 6 years that generates energy savings of 40% to 50% while maintaining existing light levels. These upgraded and field-tested solutions lower energy consumption, generate a healthy financial return on investment, and can improve both the quality and quantity of light in the task area. As with any other solution, a cost-effective lighting system must be designed and engineered carefully to accommodate the needs of each work space. Simply installing a new lamp into an existing luminaire will not necessarily guarantee substantial energy savings or an improved lighting environment. In any space that uses electric lighting, the lighting designer must evaluate potential solutions for energy consumption, maintenance concerns, delivered light levels, hostile environments, and the overall economic impact of installing and long-term operation of the new system. In this paper, the author will discuss energy efficient lighting design criteria and how a lighting designer properly engineers a retrofit project to deliver energy savings without sacrificing light levels. The discussion includes a summary of both traditional and emerging technologies, and the long-term impact on energy consumption, maintenance, return on investment, lighting quality, and delivered light levels. Paper published with permission.


2018 ◽  
Vol 248 ◽  
pp. 03001
Author(s):  
Maria Isfus Senjawati ◽  
Lusi Susanti ◽  
Hilma Raimona Zadry ◽  
Prima Fithri

Increased energy consumption can lead to depletion of fossil energy reserves that can pose a threat to energy supply in Indonesia. One way to increase the intensity of energy savings is to make changes in consumer behavior. The development of gender roles, abilities, and attention led most researchers to argue that women are more consistent in attention to environmental change than men. Women are more concerned with environmental quality and participate in environmental activities. Thus, this research tries to determine the influence of psychological factors on the behavior of household electrical energy consumption in term of gender differences. This study used questionnaires distributed using Google Docs to household electrical respondents several in Indonesia. Referring to ABC (Antecedents-Behaviour-Consequences) model of consumer behavior, the total of 808, questionnaires from 526 male respondents and 282 female respondents were successfully collected. The data were processed by the Partial Least Square Equation Modeling Model (SEM-PLS) using Smart-PLS software. The study concluded that,if given the consequences, women have higher influence to the behavior of electrical energy consumption than men. Overall psychological factors have a positive and significant influence on the behavior of electric energy consumption in Indonesia.


2020 ◽  
Vol 8 (6) ◽  
pp. 4030-4033

Around 40% of the electrical energy produced worldwide is consumed by the Buildings of Residential as well as Commercial types. Efficient usage and optimization of electrical energy leads to Nearly Zero Energy (NZE) Green Buildings and it helps in Economic growth and Social development in all countries. Apart from providing reduced energy consumption, Building energy optimization also minimizes the total energy costs, maximizes energy savings and consequently contribute less greenhouse gases to the environment. Though the installation cost of NZE Green building is quite high, the investment can be regained within the payback period with savings in the energy consumption. In this paper an Eco-friendly, Energy optimized, NZE Green building is designed by using efficient building simulation program known as BEOpt through HVAC technologies by considering various designing parameters at the designing stage and the distinguishments in the energy consumption, energy saving per year and CO2 emissions between conventional building and the designed prototype of NZE Green building are addressed.


2021 ◽  
Vol 65 (1) ◽  
pp. 113-118
Author(s):  
Hamdi Sunnetci ◽  
Deniz Yilmaz

In these days, people spend 87% of their time indoors. Therefore, buildings are responsible for 36% of the total energy consumption and 40% of the CO2 emissions in the world. Besides, energy expenditures can be reduced, especially through improvements in public buildings used by many people. In this study, an annual energy consumption was conducted for an Olympic ice-skating rink and sports complex in Istanbul with a capacity of 900 spectators, was analyzed. Annual energy consumption of the building was 2 915 032 kWh electrical energy and 157 944 m3 natural gas. It was foreseen that 40 000kWh energy savings can be achieved annually with the evaporative pre-cooling system.


2021 ◽  
Vol 4 (1) ◽  
pp. 71-80
Author(s):  
Isty Cahyani Ismail ◽  
Ramli Rahim ◽  
Baharuddin Hamzah

One of the largest energy consumers in the world is buildings. The energy consumption comes from the lighting system. Energy use in buildings is generally 25% for lighting systems. The strategy used in building design is to reduce energy consumption while maintaining the best comfort in a building. The application of energy-saving concepts from the building sector is optimizing the lighting system by integrating natural and artificial lighting systems. This study aims to determine the light intensity in the integrated lighting system of natural and artificial manually and also to find out how much energy can be saved with the integrated lighting system manually. The research location is at the Mega Bank Makassar Tower Building. The research sample was selected by purposive sampling and the sixth floor was chosen as the research location. In this study, simulations were carried out using the DIAlux 4.13 program to integrate natural and artificial light and to calculate the amount of energy efficiency in the workspace. To obtain optimal light intensity and energy savings, a simulation was carried out by turning off half the light points in the workspace, especially the light points around the building openings. The simulation results show that the average integrated lighting quality meets the minimum lighting requirements and can save energy usage by up to 50%. Keywords: energy efficiency; integration lighting; workspace


Author(s):  
Mohamed A. Umbark ◽  
Samah Khalifa Alghoul ◽  
Elhadi I. Dekam

More than one-third of the electricity generated in the world is being consumed in the residential sector. This study aims to model, simulate, and estimate electrical energy consumption in three different building styles. That is in order to compare and contrast energy consumption categories and their related social and architectural aspects for an unaddressed region that have its particular weather conditions and its special social and environmental aspects. The simulation is done by detailed modeling of the buildings using EnergyPlus. The results demonstrate that water heating systems account for almost one-fifth of the annual energy consumption. Cooling loads were found to be more than 5 times the heating loads. The peak of energy consumption was recorded to be in July, while the lowermost recorded in April and in November. The Apartment style requires the lowest annual energy consumption by an amount of 10 kWh/m2 per person followed by the Duplex house with 13 kWh/m2 per person, while the Single-Story house comes with the highest energy consumption of 18 kWh/m2 per person. These represent local power consumption of 69, 79, and 90 kWh/m2, respectively. On average, the water heating, space cooling, plus interior lights consume about 60% of total energy requirements with a mostly equal share for each, while the equipment has the maximum share of 35% of the total, leaving about 5% for the rest. The results of this study may be used as a reference line in the future for the calculations of energy savings in similar regions.


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7454
Author(s):  
Sławomir Zalewski

The operation of a concurrent lighting system using LED luminaires is based on the detection of individual road users, the recognition of their lighting needs and adjusting the operating state of the individual lighting devices that make up the system to the expectations of each user. The luminaire’s lighting divided into three independently controlled parts allows reducing electrical energy consumption up to 33% in comparison to a conventional concurrent road lighting system.