scholarly journals Sensors and instruments for oceanic dissolved carbon measurements

2009 ◽  
Vol 6 (1) ◽  
pp. 491-524 ◽  
Author(s):  
U. Schuster ◽  
A. Hannides ◽  
L. Mintrop ◽  
A. Körtzinger

Abstract. Highly accurate and precise measurements of marine carbon components are required in the study of the marine carbon cycle, particularly when investigating the causes for its variability from seasonal to interannual timescales. This is especially true in the investigation of the consequences of anthropogenic influences. The analysis of any component requires elaborate instrumentation, most of which is currently used onboard ships, either in manual mode or autonomous mode. Technological developments result in more and more instruments that have long-term reliability so that they can be deployed on surface moorings and buoys, whilst the great technological and operational challenges mean that only few sensors have been developed that can be used for sub-surface in situ measurements on floats, robots, or gliders. There is a special need for autonomous instruments and sensors that are able to measure a combination of different components, in order to increase the spatial and temporal coverage of marine carbon data. This paper describes analytical techniques used for the detection of the marine dissolved carbon components, both inorganic and organic: the fugacity of CO2, total dissolved inorganic carbon, pH, alkalinity, and dissolved organic carbon. By pointing out advantages, disadvantages, and challenges of the techniques employed in the analysis of each component, we aim to aid non-carbon marine scientists, sensor developers and technologists, in the decision where to tackle the challenges of further development.

Ocean Science ◽  
2009 ◽  
Vol 5 (4) ◽  
pp. 547-558 ◽  
Author(s):  
U. Schuster ◽  
A. Hannides ◽  
L. Mintrop ◽  
A. Körtzinger

Abstract. Highly accurate and precise measurements of marine carbon components are required in the study of the marine carbon cycle, particularly when investigating the causes for its variability from seasonal to interannual timescales. This is especially true in the investigation of the consequences of anthropogenic influences. The analysis of any marine carbon component requires elaborate instrumentation, most of which is currently used onboard ships, either in manual or automated mode. Technological developments result in more and more instruments that have sufficient long-term reliability so that they can be deployed on commercial ships, surface moorings, and buoys, whilst the great technological and operational challenges mean that only few sensors have been developed that can be used for sub-surface in situ measurements on floats, robots, or gliders. There is a special need for autonomous instruments and sensors that are able to measure a combination of different components, in order to increase the spatial and temporal coverage of marine carbon data. This paper describes analytical techniques used for the measurement of the marine dissolved carbon components, both inorganic and organic: the fugacity of CO2, total dissolved inorganic carbon, pH, alkalinity, and dissolved organic carbon. By pointing out advantages, disadvantages, and/or challenges of the techniques employed in the analysis of each component, we aim to aid non-carbon marine scientists, sensor developers and technologists, in the decision of which challenges to address in further development.


Author(s):  
Pieter Vermeesch ◽  
Martin Rittner ◽  
Irene Schimmelpfennig ◽  
Lucilla Benedetti ◽  
ASTER Team

205 Tl in the lorandite (TiAsS 2 ) mine of Allchar (Majdan, FYR Macedonia) is transformed to 205 Pb by cosmic ray reactions with muons and neutrinos. At depths of more than 300 m, muogenic production would be sufficiently low for the 4.3 Ma old lorandite deposit to be used as a natural neutrino detector. Unfortunately, the Allchar deposit currently sits at a depth of only 120 m below the surface, apparently making the lorandite experiment technically infeasible. We here present 25 erosion rate estimates for the Allchar area using in situ produced cosmogenic 36 Cl in carbonates and 10 Be in alluvial quartz. The new measurements suggest long-term erosion rates of 100–120 m Ma −1 in the silicate lithologies that are found at the higher elevations of the Majdanksa River valley, and 200–280 m Ma −1 in the underlying marbles and dolomites. These values indicate that the lorandite deposit has spent most of its existence at depths of more than 400 m, sufficient for the neutrinogenic 205 Pb component to dominate the muon contribution. Our results suggest that this unique particle physics experiment is theoretically feasible and merits further development.


Author(s):  
R. E. Herfert

Studies of the nature of a surface, either metallic or nonmetallic, in the past, have been limited to the instrumentation available for these measurements. In the past, optical microscopy, replica transmission electron microscopy, electron or X-ray diffraction and optical or X-ray spectroscopy have provided the means of surface characterization. Actually, some of these techniques are not purely surface; the depth of penetration may be a few thousands of an inch. Within the last five years, instrumentation has been made available which now makes it practical for use to study the outer few 100A of layers and characterize it completely from a chemical, physical, and crystallographic standpoint. The scanning electron microscope (SEM) provides a means of viewing the surface of a material in situ to magnifications as high as 250,000X.


Author(s):  
J. I. Bennetch

In a recent study of the superplastic forming (SPF) behavior of certain Al-Li-X alloys, the relative misorientation between adjacent (sub)grains proved to be an important parameter. It is well established that the most accurate way to determine misorientation across boundaries is by Kikuchi line analysis. However, the SPF study required the characterization of a large number of (sub)grains in each sample to be statistically meaningful, a very time-consuming task even for comparatively rapid Kikuchi analytical techniques.In order to circumvent this problem, an alternate, even more rapid in-situ Kikuchi technique was devised, eliminating the need for the developing of negatives and any subsequent measurements on photographic plates. All that is required is a double tilt low backlash goniometer capable of tilting ± 45° in one axis and ± 30° in the other axis. The procedure is as follows. While viewing the microscope screen, one merely tilts the specimen until a standard recognizable reference Kikuchi pattern is centered, making sure, at the same time, that the focused electron beam remains on the (sub)grain in question.


1975 ◽  
Vol 10 (1) ◽  
pp. 33-41 ◽  
Author(s):  
J. Butcher ◽  
M. Boyer ◽  
CD. Fowle

Abstract Eleven small ponds, lined with polyethylene, were used to assess the consequences of applications of *DursbanR at 0.004, 0.030, 0.100 and 1.000 ppm and AbateR at 0.025 and 0.100 ppm active ingredient. The treated ponds showed a more pronounced long-term increase in pH and dissolved oxygen and decreasing total and dissolved carbon dioxide in comparison with untreated ponds. Algal blooms were of longer duration in treated ponds than in controls. Total photosynthetic productivity was higher in treated ponds but bacterial numbers did not change significantly. Photosynthetic productivity was estimated by following the changes in total carbon dioxide.


2020 ◽  
Vol 20 ◽  
Author(s):  
L. Hajba ◽  
A. Guttman

: Adeno-associated virus (AAV) is one of the most promising viral gene delivery vectors with long-term gene expression and disease correction featuring high efficiency and excellent safety in human clinical trials. During the production of AAV vectors,there are several quality control (QC)parameters that should be rigorously monitored to comply with clini-cal safety and efficacy. This review gives a short summary of the most frequently used AVV production and purification methods,focusing on the analytical techniques applied to determine the full/empty capsid ratio and the integrity of the encapsidated therapeutic DNA of the products.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Sungmin O. ◽  
Rene Orth

AbstractWhile soil moisture information is essential for a wide range of hydrologic and climate applications, spatially-continuous soil moisture data is only available from satellite observations or model simulations. Here we present a global, long-term dataset of soil moisture derived through machine learning trained with in-situ measurements, SoMo.ml. We train a Long Short-Term Memory (LSTM) model to extrapolate daily soil moisture dynamics in space and in time, based on in-situ data collected from more than 1,000 stations across the globe. SoMo.ml provides multi-layer soil moisture data (0–10 cm, 10–30 cm, and 30–50 cm) at 0.25° spatial and daily temporal resolution over the period 2000–2019. The performance of the resulting dataset is evaluated through cross validation and inter-comparison with existing soil moisture datasets. SoMo.ml performs especially well in terms of temporal dynamics, making it particularly useful for applications requiring time-varying soil moisture, such as anomaly detection and memory analyses. SoMo.ml complements the existing suite of modelled and satellite-based datasets given its distinct derivation, to support large-scale hydrological, meteorological, and ecological analyses.


Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 368
Author(s):  
Lisdelys González-Rodríguez ◽  
Amauri Pereira de Oliveira ◽  
Lien Rodríguez-López ◽  
Jorge Rosas ◽  
David Contreras ◽  
...  

Ultraviolet radiation is a highly energetic component of the solar spectrum that needs to be monitored because is harmful to life on Earth, especially in areas where the ozone layer has been depleted, like Chile. This work is the first to address the long-term (five-year) behaviour of ultraviolet erythemal radiation (UVER) in Santiago, Chile (33.5° S, 70.7° W, 500 m) using in situ measurements and empirical modelling. Observations indicate that to alert the people on the risks of UVER overexposure, it is necessary to use, in addition to the currently available UV index (UVI), three more erythema indices: standard erythemal doses (SEDs), minimum erythemal doses (MEDs), and sun exposure time (tery). The combination of UVI, SEDs, MEDs, and tery shows that in Santiago, individuals with skin types III and IV are exposed to harmfully high UVER doses for 46% of the time that UVI indicates is safe. Empirical models predicted hourly and daily values UVER in Santiago with great accuracy and can be applied to other Chilean urban areas with similar climate. This research inspires future advances in reconstructing large datasets to analyse the UVER in Central Chile, its trends, and its changes.


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
La Li ◽  
Weijia Liu ◽  
Kai Jiang ◽  
Di Chen ◽  
Fengyu Qu ◽  
...  

AbstractZn-ion hybrid supercapacitors (SCs) are considered as promising energy storage owing to their high energy density compared to traditional SCs. How to realize the miniaturization, patterning, and flexibility of the Zn-ion SCs without affecting the electrochemical performances has special meanings for expanding their applications in wearable integrated electronics. Ti3C2Tx cathode with outstanding conductivity, unique lamellar structure and good mechanical flexibility has been demonstrated tremendous potential in the design of Zn-ion SCs, but achieving long cycling stability and high rate stability is still big challenges. Here, we proposed a facile laser writing approach to fabricate patterned Ti3C2Tx-based Zn-ion micro-supercapacitors (MSCs), followed by the in-situ anneal treatment of the assembled MSCs to improve the long-term stability, which exhibits 80% of the capacitance retention even after 50,000 charge/discharge cycles and superior rate stability. The influence of the cathode thickness on the electrochemical performance of the MSCs is also studied. When the thickness reaches 0.851 µm the maximum areal capacitance of 72.02 mF cm−2 at scan rate of 10 mV s−1, which is 1.77 times higher than that with a thickness of 0.329 µm (35.6 mF cm−2). Moreover, the fabricated Ti3C2Tx based Zn-ion MSCs have excellent flexibility, a digital timer can be driven by the single device even under bending state, a flexible LED displayer of “TiC” logo also can be easily lighted by the MSC arrays under twisting, crimping, and winding conditions, demonstrating the scalable fabrication and application of the fabricated MSCs in portable electronics.


Sign in / Sign up

Export Citation Format

Share Document