scholarly journals MicroRNAs - A New Generation Molecular Targets for Treating Cellular Diseases

Theranostics ◽  
2013 ◽  
Vol 3 (12) ◽  
pp. 927-929 ◽  
Author(s):  
Ramasamy Paulmurugan
2013 ◽  
Vol 2013 ◽  
pp. 1-18 ◽  
Author(s):  
Neil Vargesson

Thalidomide remains one of the world’s most notorious drugs due to the severe birth defects it induced in children between 1957 and 1962. Yet, to some this drug is a lifesaver, as it now enjoys renaissance in the treatment for a wide range of conditions including leprosy, multiple myeloma, Behcet’s disease, and some cancers. However, thalidomide has also been linked to causing a new generation of thalidomide survivors in Brazil, where the drug is used to treat leprosy. Surprisingly how thalidomide causes birth defects and how it acts in the treatment of clinical conditions are still far from clear. In the past decade great strides in our understanding of the actions of the drug, as well as molecular targets, have been made. The purpose of this review is to look at the recent work carried out into understanding how thalidomide causes birth defects, it’s molecular targets and the challenges that remain to be elucidated. These challenges include identifying clinically relevant but nonteratogenic forms of the drug, and the mechanisms underlying phocomelia and species specificity.


2013 ◽  
Vol 59 (3) ◽  
pp. 267-294 ◽  
Author(s):  
A.E. Fedosov ◽  
S.A. Moshkovskii ◽  
K.G. Kuznetsova ◽  
B.M. Olivera

A review describes general trends in research of conotoxins that are peptide toxins isolated from sea gastropods of the Conus genus, since the toxins were discovered in 1970 . There are disclosed a conotoxin classification, their structure diversity and different ways of action to their molecular targets, mainly, ion channels. In the applied aspect of conotoxin research, drug discovery and development is discussed, the drugs being based on conotoxin structure. A first exemplary drug is a ziconotide, which is an analgesic of new generation.


2020 ◽  
Vol 60 (1) ◽  
pp. 241-255 ◽  
Author(s):  
Kazuhiko Matsuda ◽  
Makoto Ihara ◽  
David B. Sattelle

Neonicotinoids have been used to protect crops and animals from insect pests since the 1990s, but there are concerns regarding their adverse effects on nontarget organisms, notably on bees. Enhanced resistance to neonicotinoids in pests is becoming well documented. We address the current understanding of neonicotinoid target site interactions, selectivity, and metabolism not only in pests but also in beneficial insects such as bees. The findings are relevant to the management of both neonicotinoids and the new generation of pesticides targeting insect nicotinic acetylcholine receptors.


2016 ◽  
Author(s):  
Sean Michael Boyle ◽  
Tom Guda ◽  
Christine Krause Pham ◽  
Sana Khalid Tharadra ◽  
Anupama Dahanukar ◽  
...  

SUMMARYDespite shortcomings, N,N-Diethyl-3-methylbenzamide (DEET) has remained the gold-standard of insect repellents for >60 years. There are significant impediments to finding improved substitutes because the molecular targets causing repellency are unclear, new chemistries will require significant human-safety testing, and predicted costs for development are exorbitant. Here we identify shared structural features important for repellency and using a supervised chemical-informatics method screen insilico >400,000 compounds to identify >100 natural compounds as candidate repellents. We select 4 candidates that are affordable, 3 approved as safe for human food use, and demonstrate that they are strong olfactory and gustatory repellents to both mosquitoes and Drosophila. The chemicals do not dissolve plastic and have a mild and pleasant odor. These repellents are representative of a new generation of affordable substitutes for DEET that can be rapidly deployed globally because of excellent human-safety profiles, and have great potential in reducing deadly diseases by reducing mosquito-human contact.


Author(s):  
D. Cherns

The use of high resolution electron microscopy (HREM) to determine the atomic structure of grain boundaries and interfaces is a topic of great current interest. Grain boundary structure has been considered for many years as central to an understanding of the mechanical and transport properties of materials. Some more recent attention has focussed on the atomic structures of metalsemiconductor interfaces which are believed to control electrical properties of contacts. The atomic structures of interfaces in semiconductor or metal multilayers is an area of growing interest for understanding the unusual electrical or mechanical properties which these new materials possess. However, although the point-to-point resolutions of currently available HREMs, ∼2-3Å, appear sufficient to solve many of these problems, few atomic models of grain boundaries and interfaces have been derived. Moreover, with a new generation of 300-400kV instruments promising resolutions in the 1.6-2.0 Å range, and resolutions better than 1.5Å expected from specialist instruments, it is an appropriate time to consider the usefulness of HREM for interface studies.


Author(s):  
Jorge Perdigao

In 1955, Buonocore introduced the etching of enamel with phosphoric acid. Bonding to enamel was created by mechanical interlocking of resin tags with enamel prisms. Enamel is an inert tissue whose main component is hydroxyapatite (98% by weight). Conversely, dentin is a wet living tissue crossed by tubules containing cellular extensions of the dental pulp. Dentin consists of 18% of organic material, primarily collagen. Several generations of dentin bonding systems (DBS) have been studied in the last 20 years. The dentin bond strengths associated with these DBS have been constantly lower than the enamel bond strengths. Recently, a new generation of DBS has been described. They are applied in three steps: an acid agent on enamel and dentin (total etch technique), two mixed primers and a bonding agent based on a methacrylate resin. They are supposed to bond composite resin to wet dentin through dentin organic component, forming a peculiar blended structure that is part tooth and part resin: the hybrid layer.


Author(s):  
S. J. Krause ◽  
W.W. Adams ◽  
S. Kumar ◽  
T. Reilly ◽  
T. Suziki

Scanning electron microscopy (SEM) of polymers at routine operating voltages of 15 to 25 keV can lead to beam damage and sample image distortion due to charging. Imaging polymer samples with low accelerating voltages (0.1 to 2.0 keV), at or near the “crossover point”, can reduce beam damage, eliminate charging, and improve contrast of surface detail. However, at low voltage, beam brightness is reduced and image resolution is degraded due to chromatic aberration. A new generation of instruments has improved brightness at low voltages, but a typical SEM with a tungsten hairpin filament will have a resolution limit of about 100nm at 1keV. Recently, a new field emission gun (FEG) SEM, the Hitachi S900, was introduced with a reported resolution of 0.8nm at 30keV and 5nm at 1keV. In this research we are reporting the results of imaging coated and uncoated polymer samples at accelerating voltages between 1keV and 30keV in a tungsten hairpin SEM and in the Hitachi S900 FEG SEM.


Author(s):  
Thomas J. Deerinck ◽  
Maryann E. Martone ◽  
Varda Lev-Ram ◽  
David P. L. Green ◽  
Roger Y. Tsien ◽  
...  

The confocal laser scanning microscope has become a powerful tool in the study of the 3-dimensional distribution of proteins and specific nucleic acid sequences in cells and tissues. This is also proving to be true for a new generation of high contrast intermediate voltage electron microscopes (IVEM). Until recently, the number of labeling techniques that could be employed to allow examination of the same sample with both confocal and IVEM was rather limited. One method that can be used to take full advantage of these two technologies is fluorescence photooxidation. Specimens are labeled by a fluorescent dye and viewed with confocal microscopy followed by fluorescence photooxidation of diaminobenzidine (DAB). In this technique, a fluorescent dye is used to photooxidize DAB into an osmiophilic reaction product that can be subsequently visualized with the electron microscope. The precise reaction mechanism by which the photooxidation occurs is not known but evidence suggests that the radiationless transfer of energy from the excited-state dye molecule undergoing the phenomenon of intersystem crossing leads to the formation of reactive oxygen species such as singlet oxygen. It is this reactive oxygen that is likely crucial in the photooxidation of DAB.


Author(s):  
S.J. Krause ◽  
W.W. Adams

Over the past decade low voltage scanning electron microscopy (LVSEM) of polymers has evolved from an interesting curiosity to a powerful analytical technique. This development has been driven by improved instrumentation and in particular, reliable field emission gun (FEG) SEMs. The usefulness of LVSEM has also grown because of an improved theoretical and experimental understanding of sample-beam interactions and by advances in sample preparation and operating techniques. This paper will review progress in polymer LVSEM and present recent results and developments in the field.In the early 1980s a new generation of SEMs produced beam currents that were sufficient to allow imaging at low voltages from 5keV to 0.5 keV. Thus, for the first time, it became possible to routinely image uncoated polymers at voltages below their negative charging threshold, the "second crossover", E2 (Fig. 1). LVSEM also improved contrast and reduced beam damage in sputter metal coated polymers. Unfortunately, resolution was limited to a few tenths of a micron due to the low brightness and chromatic aberration of thermal electron emission sources.


Author(s):  
John L. Hutchison

Over the past five years or so the development of a new generation of high resolution electron microscopes operating routinely in the 300-400 kilovolt range has produced a dramatic increase in resolution, to around 1.6 Å for “structure resolution” and approaching 1.2 Å for information limits. With a large number of such instruments now in operation it is timely to assess their impact in the various areas of materials science where they are now being used. Are they falling short of the early expectations? Generally, the manufacturers’ claims regarding resolution are being met, but one unexpected factor which has emerged is the extreme sensitivity of these instruments to both floor-borne and acoustic vibrations. Successful measures to counteract these disturbances may require the use of special anti-vibration blocks, or even simple oil-filled dampers together with springs, with heavy curtaining around the microscope room to reduce noise levels. In assessing performance levels, optical diffraction analysis is becoming the accepted method, with rotational averaging useful for obtaining a good measure of information limits. It is worth noting here that microscope alignment becomes very critical for the highest resolution.In attempting an appraisal of the contributions of intermediate voltage HREMs to materials science we will outline a few of the areas where they are most widely used. These include semiconductors, oxides, and small metal particles, in addition to metals and minerals.


Sign in / Sign up

Export Citation Format

Share Document