scholarly journals Reliability of the weight-bearing ankle dorsiflexion range of motion measurement using a smartphone goniometer application

PeerJ ◽  
2021 ◽  
Vol 9 ◽  
pp. e11977
Author(s):  
Helena Zunko ◽  
Renata Vauhnik

Background Weight-bearing ankle dorsiflexion range of motion measurement (weight-bearing lunge test) is gaining in popularity because it mimics lower extremity function in daily physical activities. The purpose of the study is to assess the intra-rater and the inter-rater reliability of the weight-bearing ankle dorsiflexion range of motion measurement with a flexed knee using a smartphone application Spirit Level Plus installed on an Android smartphone. Methods Thirty-two young, healthy subjects participated in the study and were measured in four sessions by two examiners. One measurement was taken on each ankle in every session. Eight measurements were taken from each participant. A total of 256 were taken from all the participants. The measurements for the individual subject were repeated no sooner than 24 hours after the first session. In order to assess the reliability, intraclass correlation coefficients (ICC), standard error measurements (SEM) and minimal detectable change (MDC) at the 95% confidence interval were calculated. Results Statistical data analysis revealed moderate intra-rater reliability for the right ankle (ICC = 0.72, 95% CI [0.49–0.85]) and good intra-rater reliability for the left ankle (ICC = 0.82, 95% CI [0.66–0.91]). Inter-rater reliability is moderate for the right (ICC = 0.73, 95% CI [0.52–0.86]) and the left ankle (ICC = 0.65, 95% CI [0.39–0.81]). Conclusion The observed method is moderately reliable and appropriate when the main objective is to assess ankle dorsiflexion mobility in weight-bearing when weight-bearing is not contraindicated. The concurrent validity of the Spirit Level Plus application is excellent.


2020 ◽  
Vol 10 (11) ◽  
pp. 3759
Author(s):  
Carlos Romero-Morales ◽  
Carlos López-Nuevo ◽  
Carlos Fort-Novoa ◽  
Patricia Palomo-López ◽  
David Rodríguez-Sanz ◽  
...  

Ankle sprains have been defined as the most common injury in sports. The aim of the present study was to investigate the ankle taping for the reduction of ankle dorsiflexion range of motion (ROM) and inter-limb in elite soccer and basketball players U18 in a single training session. Methods: A cross-sectional pilot study was performed on 38 male healthy elite athletes divided into two groups: a soccer group and a basketball group. Ankle dorsiflexion ROM and inter-limb asymmetries in a weight-bearing lunge position were assessed in three points: with no-tape, before the practice and immediately after the practice. Results: For the soccer group, significant differences (p < 0.05) were observed for the right ankle, but no differences for the asymmetry variable. The basketball group reported significant differences (p < 0.05) for the right ankle and symmetry. Conclusions: Ankle taping decreased the ankle dorsiflexion ROM in youth elite soccer and basketball players U18. These results could be useful as a prophylactic approach for ankle sprain injury prevention. However, the ankle ROM restriction between individuals without taping and individuals immediately assessed when the tape was removed after the training was very low.



Author(s):  
McCall Christian ◽  
Riley Koenig ◽  
Zachary Winkelmann ◽  
Kenneth Games

Purpose: Lower extremity (LE) pain accounts for 13-20% of injuries in the active population. LE pain has been contributed to inflexibility and fascial restrictions. Deep oscillation therapy (DOT) has been proposed to improve range of motion and reduce pain following musculoskeletal injuries. Therefore, our objective was to determine the effectiveness of DOT on ankle dorsiflexion range of motion (ROM) and pain in individuals with and without lower-leg pain. Methods: We used a single blind, pre-post experimental study in a research laboratory. Thirty-two active participants completed this study. Sixteen individuals reporting lower-leg pain and sixteen non-painful individuals completed the study. Participants received a single session of DOT performed by one researcher to their affected limb or matched limb. The intervention parameters included a 1:1 mode and 70-80% dosage. The intervention began by stimulating the lymphatic channels at the cisterna chyli, the inguinal lymph node, and the popliteal lymph node at a frequency of 150 Hz all for a minute each. Next, the researcher treated the triceps surae complex for 11 minutes at three different frequencies. Finally, the participant was treated distal to the popliteal lymph node at 25 Hz for 5 minutes. The main outcome measures included pain using the VAS and ankle dorsiflexion ROM with the weight-bearing lunge test (WBLT). Statistical analyses included descriptive statistics and F-test comparisons between and within groups. Results: The average WBLT measures for all participants increased 0.6 cm, which not to the minimal detectable change for passive ankle dorsiflexion ROM. Significant differences from pre-post measures were identified for pain on the VAS. Conclusion: While increases in ROM were identified, the difference was not clinically important. DOT was successful in decreasing lower-leg pain



2021 ◽  
Vol 9 (6) ◽  
pp. 4045-4050
Author(s):  
Aayushi Rathi ◽  
◽  
Priya Sahasrabuddhe ◽  

Background: Measurement of range of motion is a crucial parameter in the physiotherapeutic evaluation and follow up. Ankle dorsiflexion is important for functional activities like running, jogging, waking, stair climbing. Restricted ankle dorsiflexion is seen in various lower limb injuries. Therefore, assessment of dorsiflexion is important to assess function. Goniometer, tape measure, mobile goniometer, inclinometer is used to measure ankle dorsiflexion range of motion in weight bearing and non-weight bearing positions. Weight bearing dorsiflexion has reported higher intra and inter-rater reliability as compared to non-weight bearing ankle dorsiflexion. All these measures may be taken by the same and by different therapists in the management of one patient. Therefore, it is necessary to determine if the measurements used are reliable both within and between the therapists. Material and Methods: 50 healthy subjects were recruited and their role was explained in the study. Written consent was taken from all the subjects. Weight bearing lunge was done in which the subject was asked to stand with the heel in contact with the ground and the great toe 10 cm away from the wall and the knee touching the wall. Inclinometer, standard goniometer, mobile goniometer and tape measure were administered to check for ankle dorsifexion range of motion. Results: ICC for inter rater reliability was almost perfect for tape measure and goniometer (0.968 and 0.837 respectively) and it was substantial for inclinometer and mobile goniometer (0.746 and 0.796 respectively). ICC for intra rater reliability was almost perfect for tape measure, inclinometer and goniometer (0.965,0.894 and 0.837 respectively) and it was substantial for mobile goniometer (0.802). Conclusion: The inter-rater reliability of tape measure, goniometer is almost perfect and for mobile goniometer, inclinometer is substantial. The intra rater reliability of tape measure, inclinometer, goniometer is almost perfect and mobile goniometer is substantial. KEY WORDS: Dorsiflexion, Mobile goniometer, Tape measure, Goniometer, Inclinometer, Reliability.



Author(s):  
Henriëtte A. W. Meijer ◽  
Maurits Graafland ◽  
Miryam C. Obdeijn ◽  
Marlies P. Schijven ◽  
J. Carel Goslings

Abstract Purpose To determine the validity of wrist range of motion (ROM) measurements by the wearable-controlled ReValidate! wrist-rehabilitation game, which simultaneously acts as a digital goniometer. Furthermore, to establish the reliability of the game by contrasting ROM measurements to those found by medical experts using a universal goniometer. Methods As the universal goniometer is considered the reference standard, inter-rater reliability between surgeons was first determined. Internal validity of the game ROM measurements was determined in a test–retest setting with healthy volunteers. The reliability of the game was tested in 34 patients with a restricted range of motion, in whom the ROM was measured by experts as well as digitally. Intraclass-correlation coefficients (ICCs) were determined and outcomes were analyzed using Bland–Altman plots. Results Inter-rater reliability between experts using a universal goniometer was poor, with ICCs of 0.002, 0.160 and 0.520. Internal validity testing of the game found ICCs of − 0.693, 0.376 and 0.863, thus ranging from poor to good. Reliability testing of the game compared to medical expert measurements, found that mean differences were small for the flexion–extension arc and the radial deviation-ulnar deviation arc. Conclusion The ReValidate! game is a reliable home-monitoring device digitally measuring ROM in the wrist. Interestingly, the test–retest reliability of the serious game was found to be considerably higher than the inter-rater reliability of the reference standard, being healthcare professionals using a universal goniometer. Trial registration number (internal hospital registration only) MEC-AMC W17_003 #17.015.



PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e9687
Author(s):  
Vanina Costa ◽  
Óscar Ramírez ◽  
Abraham Otero ◽  
Daniel Muñoz-García ◽  
Sandra Uribarri ◽  
...  

Background Elbow and wrist chronic conditions are very common among musculoskeletal problems. These painful conditions affect muscle function, which ultimately leads to a decrease in the joint’s Range Of Motion (ROM). Due to their portability and ease of use, goniometers are still the most widespread tool for measuring ROM. Inertial sensors are emerging as a digital, low-cost and accurate alternative. However, whereas inertial sensors are commonly used in research studies, due to the lack of information about their validity and reliability, they are not widely used in the clinical practice. The goal of this study is to assess the validity and intra-inter-rater reliability of inertial sensors for measuring active ROM of the elbow and wrist. Materials and Methods Measures were taken simultaneously with inertial sensors (Werium™ system) and a universal goniometer. The process involved two physiotherapists (“rater A” and “rater B”) and an engineer responsible for the technical issues. Twenty-nine asymptomatic subjects were assessed individually in two sessions separated by 48 h. The procedure was repeated by rater A followed by rater B with random order. Three repetitions of each active movement (elbow flexion, pronation, and supination; and wrist flexion, extension, radial deviation and ulnar deviation) were executed starting from the neutral position until the ROM end-feel; that is, until ROM reached its maximum due to be stopped by the anatomy. The coefficient of determination (r2) and the Intraclass Correlation Coefficient (ICC) were calculated to assess the intra-rater and inter-rater reliability. The Standard Error of the Measurement and the Minimum Detectable Change and a Bland–Altman plots were also calculated. Results Similar ROM values when measured with both instruments were obtained for the elbow (maximum difference of 3° for all the movements) and wrist (maximum difference of 1° for all the movements). These values were within the normal range when compared to literature studies. The concurrent validity analysis for all the movements yielded ICC values ≥0.78 for the elbow and ≥0.95 for the wrist. Concerning reliability, the ICC values denoted a high reliability of inertial sensors for all the different movements. In the case of the elbow, intra-rater and inter-rater reliability ICC values range from 0.83 to 0.96 and from 0.94 to 0.97, respectively. Intra-rater analysis of the wrist yielded ICC values between 0.81 and 0.93, while the ICC values for the inter-rater analysis range from 0.93 to 0.99. Conclusions Inertial sensors are a valid and reliable tool for measuring elbow and wrist active ROM. Particularly noteworthy is their high inter-rater reliability, often questioned in measurement tools. The lowest reliability is observed in elbow prono-supination, probably due to skin artifacts. Based on these results and their advantages, inertial sensors can be considered a valid assessment tool for wrist and elbow ROM.



Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 71 ◽  
Author(s):  
Ke-Vin Chang ◽  
Wei-Ting Wu ◽  
Mei-Chu Chen ◽  
Yi-Chi Chiu ◽  
Der-Sheng Han ◽  
...  

Objective: This study aimed to determine the intra-rater and inter-rater reliability and validity of a hybrid device, combining virtual reality goggles, a magnetometer and an inclinometer application for smartphones, to measure craniocervical range. Summary of Background Data: Accurate evaluation of craniocervical range of motion is important for early detection of certain diseased conditions and monitoring the progress of interventions. The universal goniometer is widely used for the measurement but it requires experienced practitioners. Whether a combination of virtual reality goggles and smartphone applications can provide the same or better performance compared with the goniometer is still unknown. Methods: Forty-one healthy adults from the department of physical medicine and rehabilitation were recruited for craniocervical range examination (flexion, extension, side-bending to the right or left and rotating to the right or left) by using the hybrid device and universal goniometer. Using the hybrid device, repeated measurements were performed twice by a primary rater and once by a second rater. The primary rater also conducted a measurement using the universal goniometer in the same cohort. The intra-rater and inter-rater reliability (intra-class correlation coefficient (ICC)) were calculated using the two-way random effect model, whereas the validity was examined by the Pearson correlation coefficient and Bland-and-Altman plot. The interval between the first and second sessions of the measurement for intra-rater reliability was set at 30 min. Results: Excellent intra-rater (ICC ≥ 0.925) and inter-rater (ICC ≥ 0.880) reliability was noted for the hybrid device. The minimal detectable changes from intra-observer and inter-observer comparisons ranged between 4.12° and 7.42° in all six directions. The Bland-and-Altman plot revealed small mean differences (≤1.68°) between the hybrid device and universal goniometer. Both instruments had highly correlated measurements of craniocervical motion (r values ≥ 0.918). Conclusion: For healthy participants, excellent intra-rater and inter-rater reliability was noted for the hybrid device, and the measurements were consistent with the universal goniometer measurements. Future studies are needed to examine whether the device can perform similarly for patients with neck disorders.



Author(s):  
Matthew C. Hoch ◽  
Johanna M. Hoch ◽  
Cameron J. Powden ◽  
Emily H. Gabriel ◽  
Lauren A. Welsch

Background: The anterior reach distance and symmetry of the Y-Balance Test (YBT) has been associated with increased injury risk in collegiate athletes. Examining the influence of dorsiflexion range of motion (DROM) and single-limb balance (SLB) on YBT performance may identify underlying factors associated with injury risk. Objective: The purpose of this study is to determine if YBT anterior reach is related to DROM or SLB in collegiate varsity and club sport athletes. Methods: A convenience sample of 124 university varsity and club sport athletes (females: 99, age: 20.0 ± 1.6 years, height: 168.9 ± 12.5 kg, body mass: 68.8 ± 14.0 kg) completed the anterior direction of the YBT, weight-bearing DROM, and SLB components (firm and foam surface) of the Balance Error Scoring System on both limbs at one testing session. Relative symmetry was calculated by subtracting values of the left limb from the right limb. Results: For the left and right limb, normalized anterior reach distance was moderately correlated to DROM (R = .55, p < .001). Anterior reach distance and symmetry was weakly correlated to SLB and SLB symmetry (R = −.16 to −.03). Conclusion: There was a positive relationship between YBT anterior reach and weight-bearing DROM which was also observed in the between-limb symmetry. However, weak relationships were exhibited between YBT anterior reach and SLB. These findings may be useful for future injury prevention initiatives in athletic settings.



2020 ◽  
Vol 100 (4) ◽  
pp. 645-652
Author(s):  
David Hernández-Guillén ◽  
José-María Blasco

Abstract Background Ankle range of motion declines with age, affecting mobility and postural control. Objective The objective of this study was to investigate the effects of a talus mobilization-based intervention among healthy community-dwelling older adults presenting with limited weight-bearing ankle dorsiflexion range of motion and determine how ankle mobility evolved over the treatment. Design This was a randomized clinical trial. Setting This study was conducted in an outpatient clinic. Participants Community-dwelling, older adults over 60 years of age who had limited ankle mobility participated in this study. Interventions The experimental intervention consisted of 6 sessions of manual therapy applied in the ankle joint. The control group received the same volume of sham treatment. Measurements The primary outcome was the weight-bearing ankle dorsiflexion range of motion as measured using the lunge test. Data were collected at 9 time points: baseline, after each session, and follow-up. Results A total of 36 participants were analyzed. A single session of mobilization increased ankle range of motion by 8 degrees (95% confidence interval = 6 to 11). At the end of the sixth session, this effect had increased slightly to 11 degrees (95% confidence interval = 9 to 13). Significant between-group differences were found throughout the intervention. Limitations Optimal dose and effects from follow-up evaluations for treatment volumes of fewer than 6 sessions remain unknown. Conclusions Six sessions of a talus mobilization-based intervention in healthy community-dwelling older adults found that the greatest mobility gain in terms of the weight-bearing ankle dorsiflexion range of motion is produced after the first session. Additional sessions produce smaller improvements with a slight upward trend. Importantly, the restoration of joint mobility is enhanced over time after the end of the intervention.



2018 ◽  
Vol 21 (02) ◽  
pp. 1850009
Author(s):  
Yohei Kanno ◽  
Hajime Toda ◽  
Tsutomu Horiuchi ◽  
Masaki Katayose

Objective: The aim of this study was to establish intra-rater and inter-rater reliability of a measurement method for the pathway of the supraspinatus intramuscular tendon by 3.0 tesla MRI images. Methods: The scapula and intramuscular tendon extraction DICOM data was made to extract only a scapula domain and intramuscular tendon domain. The shear force angle anterior posterior (SFA-AP) was measured as the pathway of supraspinatus intramuscular tendon with respect to the glenoid plane on three-dimensional (3D) models of the bone and intramuscular tendon. SFA-AP of supraspinatus was measured on 3D models of the bone and intramuscular tendon. The mean and standard deviation of SFA-AP of supraspinatus was calculated. Intra-rater reliability and inter-rater reliability were evaluated by the intraclass correlation coefficient (ICC), the standard error of the mean (SEM) and the minimal detectable change (MDC). Inter-rater reliability was evaluated by three raters. Results: As for intra-rater reliability, SFA-AP of supraspinatus measured averaged [Formula: see text], with ICC (1,1) of 0.978, with ICC (1,3) of 0.993, with SEM of 0.53, with MDC of 1.46[Formula: see text]. As for inter-rater reliability, SFA-AP of supraspinatus measured averaged [Formula: see text] (rater1), SFA-AP measured averaged [Formula: see text] (rater2), SFA-AP measured averaged [Formula: see text] (rater3), with ICC (2,1) of 0.896, with ICC (2,3) of 0.963, with SEM of 1.11, with MDC of 3.09[Formula: see text]. Conclusions: 3D models of the bone and intramuscular tendon were evaluated as intra-rater and inter-rater reliabilities. SFA-AP of supraspinatus is guaranteed by one measurement.