platinum black
Recently Published Documents


TOTAL DOCUMENTS

226
(FIVE YEARS 9)

H-INDEX

28
(FIVE YEARS 1)

Polymers ◽  
2021 ◽  
Vol 13 (17) ◽  
pp. 3004
Author(s):  
Nadya Stankova ◽  
Anastas Nikolov ◽  
Ekaterina Iordanova ◽  
Georgi Yankov ◽  
Nikolay Nedyalkov ◽  
...  

We report on a new approach toward a laser-assisted modification of biocompatible polydimethylsiloxane (PDMS) elastomers relevant to the fabrication of stretchable multielectrode arrays (MEAs) devices for neural interfacing technologies. These applications require high-density electrode packaging to provide a high-resolution integrating system for neural stimulation and/or recording. Medical grade PDMS elastomers are highly flexible with low Young’s modulus < 1 MPa, which are similar to soft tissue (nerve, brain, muscles) among the other known biopolymers, and can easily adjust to the soft tissue curvatures. This property ensures tight contact between the electrodes and tissue and promotes intensive development of PDMS-based MEAs interfacing devices in the basic neuroscience, neural prosthetics, and hybrid bionic systems, connecting the human nervous system with electronic or robotic prostheses for restoring and treating neurological diseases. By using the UV harmonics 266 and 355 nm of Nd:YAG laser medical grade PDMS elastomer is modified by ns-laser ablation of in water. A new approach of processing is proposed to (i) activate the surface and to obtain tracks with (ii) symmetric U-shaped profiles and (iii) homogeneous microstructure This technology provides miniaturization of the device and successful functionalization by electroless metallization of the tracks with platinum (Pt) without preliminary sensitization by tin (Sn) and chemical activation by palladium (Pd). As a result, platinum black layers with a cauliflower-like structure with low values of sheet resistance between 1 and 8 Ω/sq are obtained.


2021 ◽  
Vol 6 (2) ◽  
pp. 131-143
Author(s):  
Evgeny N. Kabachkov ◽  
Evgeny N. Kurkin ◽  
Nikolay N. Vershinin ◽  
Igor L. Balikhin ◽  
Viktor I. Berestenko ◽  
...  

Catalysts of carbon monoxide oxidation were synthesized by deposition of platinum on titanium nitride (TiN). Two substrates with an average particle size of 18 and 36 nm were obtained by hydrogen reduction of titanium tetrachloride in a stream of microwave plasma of nitrogen. The surface of the catalysts was studied by X-ray photoelectron spectroscopy (XPS). The data obtained by us in the present work indicate the presence of oxynitride as a transition layer between nitride and oxide. It was found that the CO oxidation rate on the 9–15 wt. % Pt loaded TiN catalysts is 120 times higher than that on the platinum black with a specific surface of 30 m2g–1. Increase in the reaction rate of CO oxidation on Pt/TiN catalysts as compared to platinum black can be associated with both an increase in the concentration of CO molecules adsorbed and a decrease in the activation energy of the reaction. Catalysts are promising for use in catalytic air purification systems.


Nanomaterials ◽  
2020 ◽  
Vol 11 (1) ◽  
pp. 37
Author(s):  
Somasekhar R. Chinnadayyala ◽  
Sungbo Cho

Individuals with diabetes can benefit considerably from continuous blood glucose monitoring. To address this challenge, a proof-of-concept was performed for continuous glucose monitoring (CGM) based on an enzymeless porous nanomaterial (pNM)-modified microneedle electrode array (MNEA). The pNM sensing layer was electrochemically deposited on MNs by applying a fixed negative current of −2.5 mA cm˗2 for 400 s. The pNM-modified MNEA was packed using a biocompatible Nafion ionomer. The fabricated MNEAs were 600 × 100 × 150 µm in height, width, and thickness, respectively. The surfaces of the modified MNs were characterized by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The fabricated MNEAs showed a wide dynamic range (1–30 mM) in phosphate-buffered saline (PBS) and in artificial interstitial fluid (ISF), with good sensitivities (PBS: 1.792 ± 0.25 µA mM−1 cm−2, ISF: 0.957 ± 0.14 µA mM−1 cm−2) and low detection limits (PBS: 7.2 µM, ISF: 22 µM). The sensor also showed high stability (loss of 3.5% at the end of 16 days), selectivity, and reproducibility (Relative standard deviations (RSD) of 1.64% and 0.70% for intra- and inter-assay, respectively) and a good response time (2 s) with great glucose recovery rates in ISF (98.7–102%).


Micromachines ◽  
2020 ◽  
Vol 11 (8) ◽  
pp. 732
Author(s):  
Xinrong Li ◽  
Yilin Song ◽  
Guihua Xiao ◽  
Jingyu Xie ◽  
Yuchuan Dai ◽  
...  

Epilepsy is a common neurological disorder. There is still a lack of methods to accurately detect cortical activity and locate lesions. In this work, a flexible electrocorticography (ECoG) electrode array based on polydimethylsiloxane (PDMS)-parylene was fabricated to detect epileptiform activity under glutamate (Glu) and gamma-aminobutyric acid (GABA) modulation on primary somatosensory cortex of rats. The electrode with a thickness of 20 μm has good flexibility to establish reliable contact with the cortex. Fourteen recording sites with a diameter of 60 μm are modified by electroplating platinum black nanoparticles, which effectively improve the performance with lower impedance, obtaining a sensitive sensing interface. The electrode enables real-time capturing changes in neural activity under drug modulation. Under Glu modulation, neuronal populations showed abnormal excitability, manifested as hypsarrhythmia rhythm and continuous or periodic spike wave epileptiform activity, with power increasing significantly. Under GABA modulation, the excitement was inhibited, with amplitude and power reduced to normal. The flexible ECoG electrode array could monitor cortical activity, providing us with an effective tool for further studying epilepsy and locating lesions.


2020 ◽  
Vol 127 (2) ◽  
pp. 291-299 ◽  
Author(s):  
Rajendra P. Shukla ◽  
Robert H. Belmaker ◽  
Yuly Bersudsky ◽  
Hadar Ben-Yoav

AbstractOlanzapine is a thienobenzodiazepine compound. It is one of the newer types of antipsychotic drugs used in the treatment of schizophrenia and other psychotic disorders. Several methods have been reported for analyzing olanzapine in its pure form or combined with other drugs and in biological fluids. These methods include high-performance liquid chromatography and liquid chromatography-tandem mass spectroscopy. Although many of the reported methods are accurate and sensitive, they require the use of sophisticated equipment, lack in situ analysis, and require expensive reagents. Moreover, several of these methods are cumbersome, require prolonged sample pretreatment, strict control of pH, and long reaction times. Here we present the development of a miniaturized electrochemical sensor that will enable minimally invasive, real-time, and in situ monitoring of olanzapine levels in microliter volumes of serum samples. For this purpose, we modified a microfabricated microelectrode with a platinum black film to increase the electrocatalytic activity of the microelectrode towards olanzapine oxidation; this improved the overall selectivity and sensitivity of the sensor. We observed in recorded voltammograms the anodic current dose response characteristics in microliter volumes of olanzapine-spiked serum samples that resulted in a limit of detection of 28.6 ± 1.3 nM and a sensitivity of 0.14 ± 0.02 µA/cm2 nM. Importantly, the platinum black-modified microelectrode exhibited a limit of detection that is below the clinical threshold (65–130 nM). Further miniaturizing and integrating such sensors into point-of-care devices provide real-time monitoring of olanzapine blood levels; this will enable treatment teams to receive feedback and administer adjustable olanzapine therapy.


2019 ◽  
Vol 145 ◽  
pp. 111661 ◽  
Author(s):  
Long-Chun Wang ◽  
Ming-Hao Wang ◽  
Chao-Fan Ge ◽  
Bo-Wen Ji ◽  
Zhe-Jun Guo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document