weibull modulus
Recently Published Documents


TOTAL DOCUMENTS

134
(FIVE YEARS 25)

H-INDEX

20
(FIVE YEARS 3)

Materials ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7474
Author(s):  
Mi-Hyang Cho ◽  
Hyo-Joung Seol

Glazing is the final heat treatment process in the manufacturing of a monolithic zirconia prosthesis. Herein, the effect of cooling rate during zirconia glazing was investigated. A 3 mol% yttria-stabilized tetragonal zirconia polycrystal was glazed at the general cooling rate suggested by the manufacturer, as well as at higher and lower cooling rates, and the differences in flexural strength, hardness, optical properties, and crystal structure were evaluated. A higher cooling rate did not affect the flexural strength, hardness, grain size, optical properties, or crystal structure; however, the Weibull modulus decreased by 1.3. A lower cooling rate did not affect the flexural strength, optical properties, or crystal structure; however, the Weibull characteristic strength increased by 26.7 MPa and the Weibull modulus increased by 0.9. The decrease in hardness and the increase in grain size were statistically significant; however, the numerical differences were negligible. This study revealed that a lower cooling rate provides more reliable flexural strength. Therefore, glazing can proceed at a general cooling rate, which takes 3–4 min; however, glazing at a lower cooling rate will provide a more consistent flexural strength if desired, despite being time-consuming.


2021 ◽  
Vol 19 (6) ◽  
pp. 73-78
Author(s):  
Jaafar M. Moosa ◽  
Haider G. Abdulzahraa ◽  
Shihab A. Zaidan ◽  
Hafidh Y. Abed

The objective of this work is to study the effect of adding varying ratios of Nano Alumina to the glazing powder on glazing layer of restorative dental ceramic. The effect of addition is examined by applying Vickers hardness and surface roughness tests on the glazing layer. The specimens have been cut in a cubic form. The specimens were placed in the furnace for sintering up to temperature of 1450 oC. One specimen is glazed with glazing materials and the remaining three specimens are glazed with glazing materials but supported with varying ratios of Nano Alumina (10, 15 and 25 wt%) and all these specimens sintered at 850 oC. It was found that Vickers hardness is increased with increasing the ratios of Nano Alumina but the surface roughness decreased with increasing the ratios of Nano Alumina. Weibull modulus increased with Alumina additive increases for glass coating layer.


Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 3870
Author(s):  
Simon Guggenbühl ◽  
Abdulmonem Alshihri ◽  
Nadin Al-Haj Husain ◽  
Mutlu Özcan

The aim of this study was to evaluate four test methods on the adhesion of resin composite to resin composite, and resin composite to glass ceramic. Resin composite specimens (N = 180, Quadrant Universal LC) were obtained and distributed randomly to test the adhesion of resin composite material and to ceramic materials (IPS e.max CAD) using one of the four following tests: (a) Macroshear SBT: (n = 30), (b) macrotensile TBT: (n = 30), (c) microshear µSBT: (n = 30) and (d) microtensile µTBT test (n = 6, composite-composite:216 sticks, ceramic-composite:216 sticks). Bonded specimens were stored for 24 h at 23 °C. Bond strength values were measured using a universal testing machine (1 mm/min), and failure types were analysed after debonding. Data were analysed using Univariate and Tukey’s, Bonneferroni post hoc test (α = 0.05). Two-parameter Weibull modulus, scale (m), and shape (0) were calculated. Test method and substrate type significantly affected the bond strength results, as well as their interaction term (p < 0.05). Resin composite to resin composite adhesion using SBT (24.4 ± 5)a, TBT (16.1 ± 4.4)b and µSBT (20.6 ± 7.4)a,b test methods presented significantly lower mean bond values (MPa), compared to µTBT (36.7 ± 8.9)b (p < 0.05). When testing adhesion of glass ceramics to resin composite, µSBT (6.6 ± 1)B showed the lowest and µTBT (24.8 ± 7)C,D the highest test values (MPa) (SBT (14.6 ± 5)A,D and TBT (19.9 ± 5)A,B) (p < 0.05). Resin composite adhesion to ceramic vs. resin composite did show significant difference for the test methods SBT and µTBT (resin composite (24.4 ± 5; 36.7 ± 9 MPa) vs. glass ceramic (14.6 ± 5; 25 ± 7 MPa)) (p > 0.05). Among substrate–test combinations, Weibull distribution presented the highest shape values for ceramic–resin in µSBT (7.6) and resin–resin in µSBT (5.7). Cohesive failures in resin–resin bond were most frequently observed in SBT (87%), followed by TBT (50%) and µSBT (50%), while mixed failures occurred mostly in ceramic–resin bonds in the SBT (100%), TBT (90%), and µSBT (90%) test types. According to Weibull modulus, failure types, and bond strength, µTBT tests might be more reliable for testing resin-based composites adhesion to resin, while µSBT might be more suitable for adhesion testing of resin-based composites to ceramic materials.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Wojciech Grzebieluch ◽  
Marcin Mikulewicz ◽  
Urszula Kaczmarek

Objective. The aim was to evaluate the flexural strength, flexural modulus, microhardness, Weibull modulus, and characteristic strength of six resin composite blocks (Grandio Blocs-GR, Tetric CAD-TE, Brilliant Crios-CR, Katana Avencia-AV, Cerasmart-CS, and Shofu Block HC-HC). Methods. Flexural strength and flexural modulus were measured using a three-point bending test and microhardness using the Vickers method. Weibull analysis was also performed. Results. The materials showed flexural strength ranging from 120.38 (HC) to 186.02 MPa (GR), flexural modulus from 8.26 (HC) to 16.95 GPa (GR), and microhardness from 70.85 (AV) to 140.43 (GR). Weibull modulus and characteristic strength ranged from 16.35 (CS) to 34.98 (TE) and from 123.45 MPa (HC) to 190.3 MPa (GR), respectively. Conclusions. GR, TE, and CR presented significantly higher flexural strength, modulus, Weibull modulus, and characteristic strength than the others.


Author(s):  
Donglin Zhao ◽  
Tong Guo ◽  
Xiaomeng Fan ◽  
Chao Chen ◽  
Yue Ma

AbstractThe effect of pyrolytic carbon (PyC) thickness on the tensile property of mini T800 carbon fiber reinforced SiC matrix composites (C/SiC) was studied. PyC interphase was prepared by chemical vapor infiltration (CVI) process using C3H6–Ar as gas source, the PyC thickness was adjusted from 0 to 400 nm, and then the SiC matrix was prepared by CVI process using methyltrichlorosilane (MTS)–H2–Ar as precursor and gas source. The results showed that the tensile strength of mini T800-C/SiC increased first and then decreased with the increase of the PyC thickness. When the thickness of PyC was 100 nm, the average strength reached the maximum value of 393 ± 70 MPa. The Weibull modulus increased from 2.0 to 8.06 with the increase of PyC thickness, and the larger the Weibull modulus, the smaller the dispersion, which indicated that the regulation of PyC thickness was conducive to improve tensile properties.


2021 ◽  
Vol 52 (4) ◽  
pp. 1503-1515
Author(s):  
W.-S. Lei ◽  
G. Qian ◽  
Z. Yu ◽  
P. Zhang

Forests ◽  
2020 ◽  
Vol 11 (11) ◽  
pp. 1232
Author(s):  
Alberto Villarino ◽  
Jorge López-Rebollo ◽  
Natividad Antón

The mechanical behavior of test pieces extracted from two specimens of Pinus halepensis Mill., from the same geographical area and close to each other, was examined in this study. Using a methodology based on Digital Image Correlation (DIC) and implemented during compression strength testing, the modulus of elasticity in compression parallel to the grain (MOEc) was obtained. In addition, the value of compressive strength (MORc) was obtained for this type of wood. The research was complemented with a reliability study, determined using the Weibull modulus, from the MORc values. A microstructural and behavioral study of the most representative pieces after failure was also conducted to correlate breakage with the behavior of the pieces during the tests monitored by DIC, to link both studies. DIC was shown to be an ideal and low-cost technique for the determination of the studied properties, and obtained average values of MOEc of 50.72 MPa and MORc of 9693 MPa. These values represent fundamental data for design and calculations of wooden structures. A reliability value of between 11 and 12 was obtained using the Weibull modulus for this type of wood.


2020 ◽  
Author(s):  
Donglin Zhao ◽  
Tong Guo ◽  
X.M. Fan ◽  
Chao Chen ◽  
Yue Ma

Abstract The effect of pyrolytic carbon (PyC) thickness on the tensile property of mini T800-carbon fiber reinforced SiC matrix composites (mini-C/SiC) was studied in this work. PyC interphase was prepared by chemical vapor infiltration (CVI) process using C3H6-Ar as gas source, and the PyC thickness was adjusted from 0 to 400 nm, then the SiC matrix was prepared by CVI process using methyltrichlorosilane (MTS)-H2-Ar as precursor and gas source. The results showed that the tensile strength of mini-C/SiC increased first and then decreased with the increase of the PyC thickness. When the thickness of PyC was 100 nm, the average strength reached the maximum value of 393±70 MPa. The Weibull modulus increased from 2.0 to 8.06 with the increase of PyC thickness, the larger the Weibull modulus, the smaller the dispersion, which indicated that the regulation of PyC thickness is conducive to improve tensile properties.


2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Edmara T. P. Bergamo ◽  
Everardo N. S. de Araújo-Júnior ◽  
Adolfo C. O. Lopes ◽  
Paulo G. Coelho ◽  
Abbas Zahoui ◽  
...  

The reduced hardware design of narrow implants increases the risk of fracture not only of the implant itself but also of the prosthetic constituents. Hence, the current study is aimed at estimating the probability of survival of anterior crowns supported by different narrow implant systems. Three different narrow implant systems of internal conical connections were evaluated (Ø3.5×10 mm): (i) Active (Nobel Biocare), (ii) Epikut (S.I.N. Implant System), and (iii) BLX (Straumann). Abutments were torqued to the implants, and standardized maxillary incisor crowns were cemented. The assemblies were subjected to step-stress accelerated life testing (SSALT) in water through load application of 30 degrees off-axis lingually at the incisal edge of the crowns using a flat tungsten carbide indenter until fracture or suspension. The use level probability Weibull curves and reliability for completion of a mission of 100,000 cycles at 80 N and 120 N were calculated and plotted. Weibull modulus and characteristic strength were also calculated and plotted. Fractured samples were analyzed in a stereomicroscope. The beta (β) values were 1.6 (0.9-3.1) and 1.4 (0.9-2.2) for BLX and Active implants, respectively, and 0.5 (0.3-0.8) for the Epikut implant, indicating that failures were mainly associated with fatigue damage accumulation in the formers, but more likely associated with material strength in the latter. All narrow implant systems showed high probability of survival (≥95%, CI: 85-100%) at 80 and 120 N, without significant difference between them. Weibull modulus ranged from 6 to 14. The characteristic strength of Active, Epikut, and BLX was 271 (260-282) N, 216 (205-228) N, and 275 (264-285) N, respectively. The failure mode predominantly involved abutment and/or abutment screw fracture, whereas no narrow implant was fractured. Therefore, all narrow implant systems exhibited a high probability of survival for anterior physiologic masticatory forces, and failures were restricted to abutment and abutment screw.


Sign in / Sign up

Export Citation Format

Share Document