accelerometer cut points
Recently Published Documents


TOTAL DOCUMENTS

61
(FIVE YEARS 16)

H-INDEX

14
(FIVE YEARS 2)

2022 ◽  
Vol 120 ◽  
pp. 104126
Author(s):  
Bethany Forseth ◽  
Jordan A. Carlson ◽  
Erik A. Willis ◽  
Brian C. Helsel ◽  
Lauren T. Ptomey

PLoS ONE ◽  
2021 ◽  
Vol 16 (6) ◽  
pp. e0252615
Author(s):  
Karin Bammann ◽  
Nicola K. Thomson ◽  
Birte Marie Albrecht ◽  
Duncan S. Buchan ◽  
Chris Easton

The study of physical activity in older adults is becoming more and more relevant. For evaluation of physical activity recommendations, intensity-specific accelerometer cut-points are utilized. However, research on accelerometer cut-points for older adults is still scarce. The aim of the study was to generate placement-specific cut-points of ActiGraph GT3X+ activity counts and raw measures of acceleration to determine physical activity intensity in older adults. A further aim was to compare the validity of the generated cut-points for a range of different physical activities. The study was a single experimental trial using a convenience sample. Study participants were 20 adults aged 59 to 73 years. Accelerometers were worn at six different placements (one on each wrist, one on each ankle, and two at the hip) and breath-by-breath indirect calorimetry was used as the reference for energy. The experiment comprised of two parts; a) The first required participants to walk on a treadmill at incremental speeds (3.0–5.0 km·h-1), and b) Five different everyday activities (reading, cleaning, shopping, cycling, aerobics) were staged in the laboratory setting. Accelerometer cut-points (activity counts, raw data) were derived for each of the investigated placements by linear regression using the treadmill part. Performance of the cut-points was assessed by applying the cut-points to the everyday activities. We provide cut-points for six placements and two accelerometer metrics in the specific age group. However, the derived cut-points did not outperform published ones. More research and innovative approaches are needed for improving internal and external validity of research results across populations and age groups.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3326
Author(s):  
Jairo H. Migueles ◽  
Cristina Cadenas-Sanchez ◽  
Juan M. A. Alcantara ◽  
Javier Leal-Martín ◽  
Asier Mañas ◽  
...  

Accelerometers’ accuracy for sedentary time (ST) and moderate-to-vigorous physical activity (MVPA) classification depends on accelerometer placement, data processing, activities, and sample characteristics. As intensities differ by age, this study sought to determine intensity cut-points at various wear locations people more than 70 years old. Data from 59 older adults were used for calibration and from 21 independent participants for cross-validation purposes. Participants wore accelerometers on their hip and wrists while performing activities and having their energy expenditure measured with portable calorimetry. ST and MVPA were defined as ≤1.5 metabolic equivalents (METs) and ≥3 METs (1 MET = 2.8 mL/kg/min), respectively. Receiver operator characteristic (ROC) analyses showed fair-to-good accuracy (area under the curve [AUC] = 0.62–0.89). ST cut-points were 7 mg (cross-validation: sensitivity = 0.88, specificity = 0.80) and 1 count/5 s (cross-validation: sensitivity = 0.91, specificity = 0.96) for the hip; 18 mg (cross-validation: sensitivity = 0.86, specificity = 0.86) and 102 counts/5 s (cross-validation: sensitivity = 0.91, specificity = 0.92) for the non-dominant wrist; and 22 mg and 175 counts/5 s (not cross-validated) for the dominant wrist. MVPA cut-points were 14 mg (cross-validation: sensitivity = 0.70, specificity = 0.99) and 54 count/5 s (cross-validation: sensitivity = 1.00, specificity = 0.96) for the hip; 60 mg (cross-validation: sensitivity = 0.83, specificity = 0.99) and 182 counts/5 s (cross-validation: sensitivity = 1.00, specificity = 0.89) for the non-dominant wrist; and 64 mg and 268 counts/5 s (not cross-validated) for the dominant wrist. These cut-points can classify ST and MVPA in older adults from hip- and wrist-worn accelerometers.


Author(s):  
Philipp Birnbaumer ◽  
Pavel Dietz ◽  
Estelle Dorothy Watson ◽  
Gudani Mukoma ◽  
Alexander Müller ◽  
...  

Estimation of the intensity of physical activity (PA) based on absolute accelerometer cut points (Cp) likely over- or underestimates intensity for a specific individual. The purpose of this study was to investigate the relationship between absolute moderate intensity Cp and the first ventilatory threshold (VT1). A group of 24 pregnant and 15 nonpregnant women who performed a submaximal incremental walking test with measures of ventilatory parameters and accelerations from three different accelerometers on the wrist (ActiGraph wGT3X-BT, GENEActiv, Axivity AX3) and one on the hip (Actigraph wGT3X-BT) were analyzed. Cp were determined corresponding to 3 metabolic equivalents of task (MET), using the conventional MET definition (Cp3.5) (3.5 mL/kg×min) and individual resting metabolic rate (Cpind). The ventilatory equivalent (VE/VO2) was used to determine VT1. Accelerations at VT1 were significantly higher (p < 0.01) compared to Cp3.5 and Cpind in both groups. Cp3.5 and Cpind were significantly different in nonpregnant (p < 0.01) but not in pregnant women. Walking speed at VT1 (5.7 ± 0.5/6.2 ± 0.8 km/h) was significantly lower (p < 0.01) in pregnant compared to nonpregnant women and correspondent to 3.8 ± 0.7/4.9 ± 1.4 conventional METs. Intensity at absolute Cp was lower compared to the intensity at VT1 independent of the device or placement in pregnant and nonpregnant women. Therefore, we recommend individually tailored cut points such as the VT1 to better assess the effect of the intensity of PA.


2020 ◽  
Vol 52 (7S) ◽  
pp. 408-408
Author(s):  
Amber G. Cook ◽  
Natalie L. King ◽  
Poram Choi ◽  
Supreete Ghosh ◽  
Fabio Bertapelli ◽  
...  

Sensors ◽  
2020 ◽  
Vol 20 (10) ◽  
pp. 2776 ◽  
Author(s):  
Michael J. Duncan ◽  
Alexandra Dobell ◽  
Mark Noon ◽  
Cain C. T. Clark ◽  
Clare M. P. Roscoe ◽  
...  

(1) Background: This study sought to calibrate triaxial accelerometery, worn on both wrists, waist and both ankles, during children’s physical activity (PA), with particular attention to object control motor skills performed at a fast and slow cadence, and to cross-validate the accelerometer cut-points derived from the calibration using an independent dataset. (2) Methods: Twenty boys (10.1 ±1.5 years) undertook seven, five-minute bouts of activity lying supine, standing, running (4.5kmph−1) instep passing a football (fast and slow cadence), dribbling a football (fast and slow cadence), whilst wearing five GENEActiv accelerometers on their non-dominant and dominant wrists and ankles and waist. VO2 was assessed concurrently using indirect calorimetry. ROC curve analysis was used to generate cut-points representing sedentary, light and moderate PA. The cut-points were then cross-validated using independent data from 30 children (9.4 ± 1.4 years), who had undertaken similar activities whilst wearing accelerometers and being assessed for VO2. (3) Results: GENEActiv monitors were able to discriminate sedentary activity to an excellent level irrespective of wear location. For moderate PA, discrimination of activity was considered good for monitors placed on the dominant wrist, waist, non-dominant and dominant ankles but fair for the non-dominant wrist. Applying the cut-points to the cross-validation sample indicated that cut-points validated in the calibration were able to successfully discriminate sedentary behaviour and moderate PA to an excellent standard and light PA to a fair standard. (4) Conclusions: Cut-points derived from this calibration demonstrate an excellent ability to discriminate children’s sedentary behaviour and moderate intensity PA comprising motor skill activity.


2020 ◽  
Vol 28 (2) ◽  
pp. 255-261
Author(s):  
Quinn Malone ◽  
Steven Passmore ◽  
Michele Maiers

Different techniques used to analyze and reduce accelerometer data may impact its interpretation. To determine which variables were impacted by changing analysis parameters, the authors performed a secondary analysis of data gained from a clinical trial conducted on older adults (aged ≥65 years; M = 71.1 and SD = 5.3; n = 100) with neck and back disabilities and compared the effects of two different cut- point sets (Matthews and Freedson sets) commonly used to analyze older adult accelerometry data. The Matthews set was found to assign significantly greater moderate-to-vigorous physical activity per day than the Freedson set in all comparisons. This suggests that, if moderate-to-vigorous physical activity per unit time is a primary outcome measure, the choice of which analysis method is used should be carefully considered. Further results from analyses of dependent variables, time in moderate-to-vigorous physical activity bouts of >10 min/day, mean bout length, and number of bouts per day are discussed.


2020 ◽  
Vol 109 (9) ◽  
pp. 1825-1830 ◽  
Author(s):  
Michael J. Duncan ◽  
Emma L. J. Eyre ◽  
Val Cox ◽  
Clare M. P. Roscoe ◽  
Mark A. Faghy ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document