electromagnetic sensor
Recently Published Documents


TOTAL DOCUMENTS

240
(FIVE YEARS 43)

H-INDEX

20
(FIVE YEARS 3)

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Wu Lu ◽  
Ranran Ding ◽  
Bingjie Wu ◽  
Wenbin Zhao ◽  
Dong Huang ◽  
...  

This paper describes the design and implementation of an in-body electromagnetic sensor for patients with implanted pacemakers. The sensor can either be mounted on myocardial tissue and monitor the electrocardiography (ECG) with contact electrodes or implanted under the skin and monitor the ECG with coaxial leads. A 16-bit high-resolution analog front-end (AFE) and an energy-efficient 32-bit CPU are used for instantaneous ECG recording. Wireless data transmission between the sensor and clinician’s computer is achieved by an embedded low-power Bluetooth transmitter. In order to automatically recognize the working status of the pacemaker and alarm the episodes of arrhythmias caused by pacemaker malfunctions, pacing mode classification and fault diagnosis on the recorded ECG were achieved based on an AI algorithm, i.e., a resource allocation network (RAN). A prototype of the sensor was implemented on a human torso, and the in vitro test results prove that the sensor can work properly for the 1-4-meter transmission range.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Junxia Shang

With the gradual acceleration of modernization, metro projects have been opened for the development and construction of urban areas. How to ensure the smooth operation of subway project in public service has become the focus of urban public safety service research. In view of this content, this paper studies the subway field of urban rail transit operation and improves the public safety of urban rail transit operation. Firstly, the factors affecting the track traction power supply are analyzed, the anti-interference technology of ring array electromagnetic sensor is added, and the research scheme is formulated according to the track potential research standard to ensure the operation of the power supply system. Then, the electromagnetic sensor traction algorithm is used to detect the subway track power supply signal, and the working characteristics and advantages of single electromagnetic induction and double electromagnetic induction are analyzed. The experimental results show that compared with the traditional electromagnetic sensor power supply signal detection algorithm, the content of this paper can judge whether the power supply is normal according to electromagnetic induction, detect whether the subway traffic deviates from the track traction coordinates, and understand the size of the deviation from the track. It improves the efficiency of traction power supply detection, stabilizes the running track of subway traffic, and is conducive to the protection and development of urban public safety.


2021 ◽  
Vol 939 (1) ◽  
pp. 012009
Author(s):  
S Amirov ◽  
D Rustamov ◽  
N Yuldashev ◽  
U Mamadaliev ◽  
M Kurbanova

Abstract This article is devoted to the new electromagnetic sensor design of large direct and alternating currents with expanded functionality for the electro supply devices control and management systems on electrified railways. It’s analyzed that its nonlinear magnetic circuit with longitudinal magnetization based on the magnetization curve approximation. Also it’s shown that developed sensor sensitivity depends on working air gap sizes and modulating magnetic field induction.


2021 ◽  
Vol 11 ◽  
Author(s):  
Elisha Fredman ◽  
Bryan Traughber ◽  
Michael Kharouta ◽  
Tarun Podder ◽  
Simon Lo ◽  
...  

IntroductionAdvances in multiparametric MRI (mpMRI) combining anatomic and functional imaging can accurately identify foci of adenocarcinoma within the prostate, offering the possibility of partial gland therapy. We performed tandem prospective pilot trials to investigate the feasibility of focal prostate SBRT (f-SBRT) based on correlating diagnostic mpMRI and biopsies with confirmatory pathology in treatment planning.Materials and MethodsPatients with pathologic focal Gleason 6–7 disease and a corresponding PIRADS 4–5 lesion on mpMRI underwent targeted and comprehensive biopsies using MRI/ultrasound fusion under electromagnetic sensor navigation. After rigorous analysis for imaging biopsy concordance, five of 18 patients were eligible to proceed to f-SBRT. Chi-squared test was used for differences from expected outcomes, and concordance was estimated with binomial distribution theory and Wilson’s method.ResultsSix patients had Gleason 6 and 12 had Gleason 3 + 4 disease (mean PSA: 5.8 ng/ml, range: 2.2–8.4). Absolute concordance was 43.8% (95% CI: 0.20, 0.64). Patterns of discordance included additional sites of ipsilateral disease, bilateral disease, and negative target. Five were upstaged to a new NCCN risk category necessitating treatment escalation. The five patients with concordant pathology completed three-fraction f-SBRT with sparing of the surrounding normal structures (including contralateral neurovascular bundle), with no reported grade 2+ toxicities and favorable PSA responses (mean: 41% decrease).ConclusionsOn our pilot trials of f-SBRT planning using rigorous imaging and pathology concordance, image-guided confirmatory biopsies frequently revealed additional disease, suggesting the need for caution in partial-gland therapy. For truly focal disease, f-SBRT provided excellent dosimetry, minimal toxicity, and encouraging biochemical response. Clinical Trial Registration: www.clinicaltrials.gov, NCT02681614; NCT02163317.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Shintaro Mukohara ◽  
Yutaka Mifune ◽  
Atsuyuki Inui ◽  
Hanako Nishimoto ◽  
Takashi Kurosawa ◽  
...  

Abstract Background The accurate assessment of distal radioulnar joint (DRUJ) instability is still challenging as there is no established objective evaluation method. This study aimed to develop a noninvasive measurement method using a three-dimensional electromagnetic sensor system (EMS) to quantitatively assess and characterize the normal DRUJ movement in healthy volunteers. Methods The DRUJ movement was mimicked using both a block model and saw bone. Movement of the models was measured by EMS, and the accuracy and reproducibility of the measurements were assessed. In vivo measurement was performed in a sitting position with the elbow flexed and the forearm pronated. One sensor each was attached to the distal radial shaft and the ulnar head. The examiners fixed the distal radius and the carpal bones, moved the ulnar head from the dorsal to the volar side and measured the dorsovolar translation. The volar translation was measured by EMS and ultrasonography, and the correlation coefficient was calculated. The dorsovolar translation was evaluated in 14 healthy volunteers (7 men and 7 women) by three hand surgeons. The intraclass and inter-rater correlation coefficients (ICCs), the differences between the dominant and non-dominant sides and between men and women were assessed. Results The accuracy and reproducibility assessment results of the EMS showed high accuracy and reproducibility. In the comparison between EMS and ultrasonography, the correlation coefficient was 0.920 (p = 0.16 × 10-3). The ICC (1,5) for the intra-rater reliability was 0.856, and the ICC (2,5) for inter-rater reliability was 0.868. The mean ulnar head translation and difference between dominant and non-dominant sides were 6.00 ± 1.16 mm (mean ± SD) and − 0.12 ± 0.40 mm, respectively. There were no significant differences between any of the parameters. Conclusions A new measurement method using EMS could evaluate DRUJ movement with high accuracy, reproducibility, and intra- and inter-rater reliability. In healthy volunteers, the dorsovolar ulnar head translation was 6.00 mm. The difference between the dominant and non-dominant sides was < 1.0 mm with no significant difference. EMS provided an objective, non-invasive, real-time assessment of dynamic changes in the DRUJ. These findings could be useful in the treatment of patients with DRUJ instability.


2021 ◽  
Author(s):  
Leandro Beltrachini ◽  
Nicolas von Ellenrieder ◽  
Roland Eichardt ◽  
Jens Haueisen

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4434
Author(s):  
Zhenyu Bao ◽  
Jingyu Zhao ◽  
Pu Huang ◽  
Shanshan Yong ◽  
Xinan Wang

The influence of earthquake disasters on human social life is positively related to the magnitude and intensity of the earthquake, and effectively avoiding casualties and property losses can be attributed to the accurate prediction of earthquakes. In this study, an electromagnetic sensor is investigated to assess earthquakes in advance by collecting earthquake signals. At present, the mainstream earthquake magnitude prediction comprises two methods. On the one hand, most geophysicists or data analysis experts extract a series of basic features from earthquake precursor signals for seismic classification. On the other hand, the obtained data related to earth activities by seismograph or space satellite are directly used in classification networks. This article proposes a CNN and designs a 3D feature-map which can be used to solve the problem of earthquake magnitude classification by combining the advantages of shallow features and high-dimensional information. In addition, noise simulation technology and SMOTE oversampling technology are applied to overcome the problem of seismic data imbalance. The signals collected by electromagnetic sensors are used to evaluate the method proposed in this article. The results show that the method proposed in this paper can classify earthquake magnitudes well.


2021 ◽  
Author(s):  
Shintaro Mukohara ◽  
Yutaka Mifune ◽  
Atsuyuki Inui ◽  
Hanako Nishimoto ◽  
Kohei Yamaura ◽  
...  

Abstract Background The accurate assessment of distal radioulnar joint (DRUJ) instability is still challenging as there is no established objective evaluation method. This study aimed to develop a noninvasive measurement method using a three-dimensional electromagnetic sensor system (EMS) to quantitatively assess and characterize the normal DRUJ movement in healthy volunteers. Methods The DRUJ movement was mimicked using both a block model and saw bone. Movement of the models was measured by EMS, and the accuracy and reproducibility of the measurements were assessed. The movement was evaluated in 14 healthy volunteers (7 men and 7 women) by three hand surgeons. Measurement was done in a sitting position with the elbow flexed and the forearm pronated. One sensor each was attached to the distal radial shaft and the ulnar head. The examiners fixed the distal radius and moved the ulnar head from the dorsal to the volar side, measuring the dorsovolar ulnar head translation. The intraclass and interrater correlation coefficients (ICCs) were calculated using the average values of the measurements. The differences between the dominant and non-dominant sides and between men and women were also assessed. Results The accuracy and reproducibility assessment results of the EMS showed high accuracy and reproducibility. The ICC (1,5) for the intra-rater reliability was 0.856, and the ICC (2,5) for inter-rater reliability was 0.868. The mean ulnar head translation and difference between dominant and non-dominant sides were 6.00 ± 1.16 mm (Mean ± SD) and -0.12 ± 0.40 mm, respectively. There were no significant differences between any of the parameters.Conclusions A new measurement method using EMS could evaluate DRUJ movement with high accuracy, reproducibility, and intra- and inter-rater reliability. In healthy volunteers, the dorsovolar ulnar head translation was 6.00 mm. The difference between the dominant and non-dominant sides was < 1.0 mm with no significant difference. EMS provided an objective, non-invasive, real-time assessment of dynamic changes in the DRUJ. These findings could be useful in the treatment of patients with DRUJ instability.


Electronics ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 721
Author(s):  
Maha Aldoumani ◽  
Baris Yuce ◽  
Dibin Zhu

In this paper, the performance, modelling and application of a planar electromagnetic sensor are discussed. Due to the small size profiles and their non-contact nature, planar sensors are widely used due to their simple and basic design. The paper discusses the experimentation and the finite element modelling (FEM) performed for developing the design of planar coils. In addition, the paper investigates the performance of various topologies of planar sensors when they are used in inductive sensing. This technique has been applied to develop a new displacement sensor. The ANSYS Maxwell FEM package has been used to analyse the models while varying the topologies of the coils. For this purpose, different models in FEM were constructed and then tested with topologies such as circular, square and hexagon coil configurations. The described methodology is considered an effective way for the development of sensors based on planar coils with better performance. Moreover, it also confirms a good correlation between the experimental data and the FEM models. Once the best topology is chosen based on performance, an optimisation exercise was then carried out using uncertainty models. That is, the influence of variables such as number of turns and the spacing between the coils on the output inductance has been investigated. This means that the combined effects of these two variables on the output inductance was studied to obtain the optimum values for the number of turns and the spacing between the coils that provided the highest level of inductance from the coils. Integrated sensor systems are a pre-requisite for developing the concept of smart cities in practice due to the fact that the individual sensors can hardly meet the demands of smart cities for complex information. This paper provides an overview of the theoretical concept of smart cities and the integrated sensor systems.


Sign in / Sign up

Export Citation Format

Share Document