pixel pitch
Recently Published Documents


TOTAL DOCUMENTS

176
(FIVE YEARS 38)

H-INDEX

14
(FIVE YEARS 3)

2022 ◽  
Vol 17 (01) ◽  
pp. C01041
Author(s):  
A. Sarno ◽  
R.M. Tucciariello

Abstract Virtual clinical trials in X-ray breast imaging permit to compare different technical solutions and imaging modalities at reduced costs, involved personnel, reduced times and reduced radiation risks to patients. In this context, the detector characteristics (spatial resolution, noise level and efficiency) play a key role for an appropriate generation of simulated images. The project AGATA proposes to compute images as dose deposit maps in a detector layer of defined materials. Simulated images are then post-processed on the basis of suitable comparison between intrinsic characteristics of real and simulated detectors. With this scope, as first step for the post-processing manipulations, we evaluated the presampled modulation transfer function (MTF), the detector-response function and the noise power spectrum (NPS) of the simulated detectors. Two detectors were simulated: (1) 0.20 mm-thick a-Se direct flat panel with 70 µm pixel pitch and (2) CsI(Tl) indirect flat panel with 100 µm pixel pitch and scintillator layer 0.25 mm thick. In addition, the impact of simulating the de-excitation processes (Auger emission and fluorescence) was explored. Simulated detector characteristics were evaluated for W/Rh spectra between 25 kV and 31 kV. The in-silico platform used a Monte Carlo software based on Geant4 toolkit (vers. 6). First, the simulation and tracking of electrons generated from photoelectric or Compton interactions was shown to have neglectable influence on the pixel values for the explored spectra, with the produced electrons presenting short ranges with respect to the pixel dimension. In the case of the CsI detector, which has fluorescence energies higher than those of the simulated X-ray photons, the deexcitation processes have not noticeable influence on the calculated pixel values. On the other hand, the MTF of the a-Se detector resulted slightly lower when the fluorescence is simulated in the detector materials, due to the dose spread derived from the fluorescence photons, which can travel far from the initial ionization interaction. Regarding the a-Se detector, the noise power spectrum resulted lower with simulated deexcitation.


2021 ◽  
pp. 100181
Author(s):  
Wenqi Wang ◽  
Zhen Deng ◽  
Xinxin Li ◽  
Lili Han ◽  
Junyang Zhang ◽  
...  

2021 ◽  
Vol 6 (1) ◽  
pp. 68
Author(s):  
Jorge Jimenez ◽  
Antoni Grau

To make Europe competitive in the field of astronomical sensors and detectors, the main goal of this research is to provide the capability to manufacture high performance infrared focal plane arrays (FPA) devoted to scientific and astronomical ground and space telescope missions. This paper presents the main outcome of an international project with the highest standard of quality for this detector. The resulting detector is a sensor with a hybridized MCT (HgCdTe) epilayer on a CdZnTe substrate of 2 k × 2 k pixels and 15 μm of pixel pitch. On this framework, an optical setup has been developed at the IFAE optical laboratory with the capabilities to perform the characterization of a near-infrared (NIR) detector covering the range from 800 to 2500 nm. The optical setup is mainly composed of a power controlled quartz–halogen (QTH) lamp and an astigmatism-corrected Czerny–Turner monochromator with two diffraction gratings covering the detector wavelength range with a minimum resolution of ∼1 nm. A temperature stabilized gold-coated integration sphere provides a uniform and monochromatic illumination, while an InGaAs photodiode located at the north pole of the integration sphere is used to measure the radiant flux toward the detector. The whole setup is fully controlled by a Labview™ application and synchronized with the detector’s readout electronic (ROE).


2021 ◽  
Vol 2 (1) ◽  
Author(s):  
Naïg Aurelia Ludmilla Chenais ◽  
Marta Jole Ildelfonsa Airaghi Leccardi ◽  
Diego Ghezzi

AbstractRetinal prostheses hold the promise of restoring vision in totally blind people. However, a decade of clinical trials highlighted quantitative limitations hampering the possibility of reaching this goal. A key challenge in retinal stimulation is to independently activate retinal neurons over a large portion of the subject’s visual field. Reaching such a goal would significantly improve the perception accuracy in retinal implants’ users, along with their spatial cognition, attention, ambient mapping and interaction with the environment. Here we show a wide-field, high-density and high-resolution photovoltaic epiretinal prosthesis for artificial vision (POLYRETINA). The prosthesis embeds 10,498 physically and functionally independent photovoltaic pixels, allowing for wide retinal coverage and high-resolution stimulation. Single-pixel illumination reproducibly induced network-mediated responses from retinal ganglion cells at safe irradiance levels. Furthermore, POLYRETINA allowed response discrimination with a high spatial resolution equivalent to the pixel pitch (120 µm) thanks to the network-mediated stimulation mechanism. This approach could allow mid-peripheral artificial vision in patients with retinitis pigmentosa.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1550
Author(s):  
Dominic Greiffenberg ◽  
Marie Andrä ◽  
Rebecca Barten ◽  
Anna Bergamaschi ◽  
Martin Brückner ◽  
...  

Chromium compensated GaAs or GaAs:Cr sensors provided by the Tomsk State University (Russia) were characterized using the low noise, charge integrating readout chip JUNGFRAU with a pixel pitch of 75 × 75 µm2 regarding its application as an X-ray detector at synchrotrons sources or FELs. Sensor properties such as dark current, resistivity, noise performance, spectral resolution capability and charge transport properties were measured and compared with results from a previous batch of GaAs:Cr sensors which were produced from wafers obtained from a different supplier. The properties of the sample from the later batch of sensors from 2017 show a resistivity of 1.69 × 109 Ω/cm, which is 47% higher compared to the previous batch from 2016. Moreover, its noise performance is 14% lower with a value of (101.65 ± 0.04) e− ENC and the resolution of a monochromatic 60 keV photo peak is significantly improved by 38% to a FWHM of 4.3%. Likely, this is due to improvements in charge collection, lower noise, and more homogeneous effective pixel size. In a previous work, a hole lifetime of 1.4 ns for GaAs:Cr sensors was determined for the sensors of the 2016 sensor batch, explaining the so-called “crater effect” which describes the occurrence of negative signals in the pixels around a pixel with a photon hit due to the missing hole contribution to the overall signal causing an incomplete signal induction. In this publication, the “crater effect” is further elaborated by measuring GaAs:Cr sensors using the sensors from 2017. The hole lifetime of these sensors was 2.5 ns. A focused photon beam was used to illuminate well defined positions along the pixels in order to corroborate the findings from the previous work and to further characterize the consequences of the “crater effect” on the detector operation.


Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 888
Author(s):  
Dionysios Linardatos ◽  
Vaia Koukou ◽  
Niki Martini ◽  
Anastasios Konstantinidis ◽  
Athanasios Bakas ◽  
...  

Certain imaging performance metrics are examined for a state-of-the-art 20 μm pixel pitch CMOS sensor (RadEye HR), coupled to a Gd2O2S:Tb scintillator screen. The signal transfer property (STP), the modulation transfer function (MTF), the normalized noise power spectrum (NNPS) and the detective quantum efficiency (DQE) were estimated according to the IEC 62220-1-1:2015 standard. The detector exhibits excellent linearity (coefficient of determination of the STP linear regression fit, R2 was 0.9978), while its DQE peaks at 33% and reaches 10% at a spatial frequency of 3 cycles/mm, for the measured with a Piranha RTI dosimeter (coefficient of variation CV = 0.03%) exposure value of 28.1 μGy DAK (detector Air Kerma). The resolution capabilities of the X-ray detector under investigation were compared to other commercial CMOS sensors, and were found in every case higher, except from the previous RadEye HR model (CMOS—Gd2O2S:Tb screen pair with 22.5 μm pixel pitch) version which had slightly better MTF. The present digital imager is designed for industrial inspection applications, nonetheless its applicability to medical imaging, as well as dual-energy is considered and certain approaches are discussed in this respect.


2021 ◽  
pp. 1-1
Author(s):  
Yan-Gang Xu ◽  
Chong-Peng Ruan ◽  
Lei Zhou ◽  
Jian-Hua Zou ◽  
Miao Xu ◽  
...  
Keyword(s):  