Withdrawal: On‐line fault diagnosis model for rigid ceramic filters based on outlet concentration and dynamic pressure, by Longfei Liu, Zhongli Ji, and Xin Luan

AIChE Journal ◽  
2020 ◽  
Vol 66 (6) ◽  
Author(s):  
Longfei Liu ◽  
Zhongli Ji ◽  
Xin Luan

Sudden fractures in rigid ceramic filter tubes hinder the stable long-term operation of advanced power-generation processes. In this study, Time difference of arrival (TDOA) of dynamic pressure in the inner wall of filter during pulse jet cleaning process and outlet concentration with diameter of leakage during filtration and pulse jet cleaning process are investigated using high frequency sensors and optical particle spectrometry. The outlet concentrations measured under different leakage agreed with the theoretical values, with the peak outlet concentration being 2.5 times greater than stable outlet concentration. There is a linear relationship between leakage aperture and theoretical outlet concentration in leaking ceramic filter tubes. A positioning model that can precisely locate the leaking ceramic filter tube using the time difference in the dynamic pressure as measured at different positions is established. This research can quickly and accurately determine whether a ceramic filter tube is broken and location of breakage.


2018 ◽  
Vol 88-90 ◽  
pp. 1274-1280 ◽  
Author(s):  
Mei Fei ◽  
Liu Ning ◽  
Miao Huiyu ◽  
Pan Yi ◽  
Sha Haoyuan ◽  
...  

2014 ◽  
Vol 519-520 ◽  
pp. 1169-1172
Author(s):  
De Wen Wang ◽  
Lin Xiao He

With the development of on-line monitoring technology of electric power equipment, and the accumulation of both on-line monitoring data and off-line testing data, the data available to fault diagnosis of power transformer is bound to be massive. How to utilize those massive data reasonably is the issue that eagerly needs us to study. Since the on-line monitoring technology is not totally mature, which resulting in incomplete, noisy, wrong characters for monitoring data, so processing the initial data by using rough set is necessary. Furthermore, when the issue scale becomes larger, the computing amount of association rule mining grows dramatically, and its easy to cause data expansion. So it needs to use attribute reduction algorithm of rough set theory. Taking the above two points into account, this paper proposes a fault diagnosis model for power transformer using association rule mining-based on rough set.


Processes ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 919
Author(s):  
Wanlu Jiang ◽  
Chenyang Wang ◽  
Jiayun Zou ◽  
Shuqing Zhang

The field of mechanical fault diagnosis has entered the era of “big data”. However, existing diagnostic algorithms, relying on artificial feature extraction and expert knowledge are of poor extraction ability and lack self-adaptability in the mass data. In the fault diagnosis of rotating machinery, due to the accidental occurrence of equipment faults, the proportion of fault samples is small, the samples are imbalanced, and available data are scarce, which leads to the low accuracy rate of the intelligent diagnosis model trained to identify the equipment state. To solve the above problems, an end-to-end diagnosis model is first proposed, which is an intelligent fault diagnosis method based on one-dimensional convolutional neural network (1D-CNN). That is to say, the original vibration signal is directly input into the model for identification. After that, through combining the convolutional neural network with the generative adversarial networks, a data expansion method based on the one-dimensional deep convolutional generative adversarial networks (1D-DCGAN) is constructed to generate small sample size fault samples and construct the balanced data set. Meanwhile, in order to solve the problem that the network is difficult to optimize, gradient penalty and Wasserstein distance are introduced. Through the test of bearing database and hydraulic pump, it shows that the one-dimensional convolution operation has strong feature extraction ability for vibration signals. The proposed method is very accurate for fault diagnosis of the two kinds of equipment, and high-quality expansion of the original data can be achieved.


2007 ◽  
Vol 359-360 ◽  
pp. 518-522
Author(s):  
Wan Shan Wang ◽  
Tian Biao Yu ◽  
Xing Yu Jiang ◽  
Jian Yu Yang

Remote control and fault diagnosis of ultrahigh speeding grinding is studied, which is based on the theory of rough set. Knowledge acquisition and reduction rule of fault diagnosis, realization method of remote control for ultrahigh speed grinding are studied, diagnosis model is established. Based on the theoretical research and ultrahigh speed grinder with a linear speed of 250 m/s, the remote control and fault diagnosis system of ultrahigh speed grinding is developed. Results of the system running show that the environment is improved, the mental pressure of workers is relieved and the efficiency is improved. At the same time, it proves that the ability to diagnosis and the accuracy of diagnosis for the ultrahigh speed grinding are improved and the time for diagnosis is shortened by applying rough set.


Sign in / Sign up

Export Citation Format

Share Document