Evaluation of a simple, inexpensive, in situ sampler for measuring time-weighted average concentrations of suspended sediment in rivers and streams

2019 ◽  
Vol 33 (5) ◽  
pp. 678-686 ◽  
Author(s):  
Nicholas J.C. Doriean ◽  
Peter R. Teasdale ◽  
David T. Welsh ◽  
Andrew P. Brooks ◽  
William W. Bennett
Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 965
Author(s):  
Xingyue Zhu ◽  
Kaixiong Yu ◽  
Xiaofan Zhu ◽  
Juan Su ◽  
Chi Wu

Nowadays, it is still a challenge for commercial nitrate sensors to meet the requirement of high accuracy in a complex water. Based on deep-ultraviolet spectral analysis and a regression algorithm, a different measuring method for obtaining the concentration of nitrate in seawater is proposed in this paper. The system consists of a deuterium lamp, an optical fiber splitter module, a reflection probe, temperature and salinity sensors, and a deep-ultraviolet spectrometer. The regression model based on weighted average kernel partial least squares (WA-KPLS) algorithm together with corrections for temperature and salinity (TSC) is established. After that, the seawater samples from Western Pacific and Aoshan Bay in Qingdao, China with the addition of various nitrate concentrations are studied to verify the reliability and accuracy of the method. The results show that the TSC-WA-KPLS algorithm shows the best results when compared against the multiple linear regression (MLR) and ISUS (in situ ultraviolet spectrophotometer) algorithms in the temperatures range of 4–25 °C, with RMSEP of 0.67 µmol/L for Aoshan Bay seawater and 1.08 µmol/L for Western Pacific seawater. The method proposed in this paper is suitable for measuring the nitrate concentration in seawater with higher accuracy, which could find application in the development of in-situ and real-time nitrate sensors.


2017 ◽  
Vol 27 (1) ◽  
pp. 42-47 ◽  
Author(s):  
Jennifer C. Urquhart ◽  
Osama A. Alrehaili ◽  
Charles G. Fisher ◽  
Alyssa Fleming ◽  
Parham Rasoulinejad ◽  
...  

OBJECTIVEA multicenter, prospective, randomized equivalence trial comparing a thoracolumbosacral orthosis (TLSO) to no orthosis (NO) in the treatment of acute AO Type A3 thoracolumbar burst fractures was recently conducted and demonstrated that the two treatments following an otherwise similar management protocol are equivalent at 3 months postinjury. The purpose of the present study was to determine whether there was a difference in long-term clinical and radiographic outcomes between the patients treated with and those treated without a TLSO. Here, the authors present the 5- to 10-year outcomes (mean follow-up 7.9 ± 1.1 years) of the patients at a single site from the original multicenter trial.METHODSBetween July 2002 and January 2009, a total of 96 subjects were enrolled in the primary trial and randomized to two groups: TLSO or NO. Subjects were enrolled if they had an AO Type A3 burst fracture between T-10 and L-3 within the previous 72 hours, kyphotic deformity < 35°, no neurological deficit, and an age of 16–60 years old. The present study represents a subset of those patients: 16 in the TLSO group and 20 in the NO group. The primary outcome measure was the Roland Morris Disability Questionnaire (RMDQ) score at the last 5- to 10-year follow-up. Secondary outcome measures included kyphosis, satisfaction, the Numeric Rating Scale for back pain, and the 12-Item Short-Form Health Survey (SF-12) Mental and Physical Component Summary (MCS and PCS) scores. In the original study, outcome measures were administered at admission and 2 and 6 weeks, 3 and 6 months, and 1 and 2 years after injury; in the present extended follow-up study, the outcome measures were administered 5–10 years postinjury. Treatment comparison between patients in the TLSO group and those in the NO group was performed at the latest available follow-up, and the time-weighted average treatment effect was determined using a mixed-effects model of longitudinal regression for repeated measures averaged over all time periods. Missing data were assumed to be missing at random and were replaced with a set of plausible values derived using a multiple imputation procedure.RESULTSThe RMDQ score at 5–10 years postinjury was 3.6 ± 0.9 (mean ± SE) for the TLSO group and 4.8 ± 1.5 for the NO group (p = 0.486, 95% CI −2.3 to 4.8). Average kyphosis was 18.3° ± 2.2° for the TLSO group and 18.6° ± 3.8° for the NO group (p = 0.934, 95% CI −7.8 to 8.5). No differences were found between the NO and TLSO groups with time-weighted average treatment effects for RMDQ 1.9 (95% CI −1.5 to 5.2), for PCS −2.5 (95% CI −7.9 to 3.0), for MCS −1.2 (95% CI −6.7 to 4.2) and for average pain 0.9 (95% CI −0.5 to 2.2).CONCLUSIONSCompared with patients treated with a TLSO, patients treated using early mobilization without orthosis maintain similar pain relief and improvement in function for 5–10 years.


Nanomaterials ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 2546
Author(s):  
Rikke Bramming Jørgensen ◽  
Ida Teresia Kero ◽  
Aleksander Blom ◽  
Esten Eide Grove ◽  
Kristin von Hirsch Svendsen

Background: It is difficult to assess workers’ exposure to ultrafine particles (UFP) due to the lack of personal sampling equipment available for this particle fraction. The logbook method has been proposed as a general method for exposure assessment. This method measures the time and concentration components of the time-weighted average concentration separately and could be suitable for investigation of UFP exposure. Objectives: In this study, we have assessed workers’ exposure to UFP in a ferrosilicon plant. The main tasks of the furnace workers were identified, and the logbook method was used in combination with stationary measurements of UFP taken as close to the identified task areas as possible. In order to verify the results, respirable particles were collected using stationary sampling in close proximity to the UFP measuring instrument, and personal full-shift sampling of respirable particles was performed simultaneously. Thus, exposure to respirable particles determined using the logbook method could be compared to the results of standard measurement. Methods: The particle number concentration of ultrafine particles was determined using a NanoScan SMPS. Respirable particle concentration and exposure were determined using a sampling train consisting of a pump, filter, filter cassettes, and SKC Cyclone for the respirable fraction. Attendance times for workers at each work location were registered via thorough observations made by the research team. Results: The logbook method for exposure estimation based on stationary sampling equipment made it possible to calculate UFP exposure for workers operating the furnaces at a ferrosilicon plant. The mid-size furnace and the large furnace were evaluated separately. The workers operating the largest furnace were exposed to 1.47 × 104 particles/cm3, while workers operating the mid-size furnace were exposed to 2.06 × 104 particles/cm3, with a mean of 1.74 × 104 particles/cm3. Substantial contributions from the casting area, ladle transport corridor, and both tapping areas were made. Exposure to respirable particles was 2.04 mg/m3 (logbook); 2.26 mg/m3 (personal sampling) for workers operating the large-sized furnace, 3.24 mg/m3 (logbook); 2.44 mg/m3 (personal sampling) for workers operating the medium-sized furnace, and 2.57 mg/m3 (logbook); 2.53 mg/m3(personal sampling) on average of all tappers. The average ratio of these two methods’ results was 1.02, which indicates that the logbook method could be used as a substitute for personal sampling when it is not possible to perform personal sampling, at least within this industry. Conclusions: The logbook method is a useful supplement for exposure assessment of UFP, able to identify the most polluted areas of the workplace and the contribution of different work tasks to the total exposure of workers, enabling companies to take action to reduce exposure.


2020 ◽  
Vol 185 (9-10) ◽  
pp. e1551-e1555
Author(s):  
Sean E Slaven ◽  
Benjamin M Wheatley ◽  
Daniel L Christensen ◽  
Sameer K Saxena ◽  
Robert J McGill

Abstract Introduction Noise exposure is an occupational health concern for certain professions, especially military servicemembers and those using power tools on a regular basis. The purpose of this study was to quantify noise exposure during total hip arthroplasty (THA) and total knee arthroplasty (TKA) cases compared to the recommended standard for occupational noise exposure. Materials and Methods A sound level meter was used to record cumulative and peak noise exposure levels in 10 primary THA and 10 primary TKA surgeries, as well as 10 arthroscopy cases as controls. Measurements at the distance of the surgeon were taken in all cases. In TKA cases, measurements were taken at 3 feet and 8 feet from the surgeon, to simulate the position of the anesthetist and circulating nurse, respectively. Results Time-weighted average was significantly higher in THA (64.7 ± 5.2 dB) and TKA (64.5 ± 6.8 dB) as compared to arthroscopic cases (51.1 ± 7.5 dB, P &lt; 0.001) and higher at the distance of the surgeon (64.5 ± 6.8 dB) compared to the anesthetist (52.9 ± 3.8 dB) and the circulating nurse (54.8 ± 11.2 dB, P = 0.006). However, time-weighted average was below the recommended exposure level of 85 dB for all arthroplasty cases. Peak levels did not differ significantly between surgery type or staff role, and no values above the ceiling limit of 140 dB were recorded. Surgeon’s daily noise dose percentage per case was 1.78% for THA and 2.04% for TKA. Conclusion Noise exposure in THA and TKA was higher than arthroscopic cases but did not exceed occupational standards. A daily dose percentage of approximately 2% per case indicates that repeated noise exposure likely does not reach hazardous levels in modern arthroplasty practice.


2021 ◽  
Author(s):  
David Schneberger ◽  
Upkardeep Singh Pandher ◽  
Brooke Thompson ◽  
Shelley Kirychuk

Abstract Workplaces with elevated organic dust levels such as animal feed barns also commonly have elevated levels of gasses, such as CO2. Workers exposed to such complex environments often experience respiratory effects that may be due to a combination of respirable factors. We examined the effects of CO2 at the ASHRAE recommended limit (1000 ppm) as well as the EPA 8hr time weighted average limit (5000 ppm) on lung innate immune responses in mice with exposure to inflammatory lipopolysaccharide and organic dust. Mice were nasally instilled with dust extracts or LPS and immediately put into chambers with a constant flow of room air (approx. 430 ppm CO2), 1000 ppm, or 5000 ppm CO2 enriched air. Organic dust exposures tended to show decreased inflammatory responses with 1000 ppm CO2 and increased responses at 5000 ppm CO2. Conversely, LPS with addition of CO2 as low as 1000 ppm tended to inhibit several inflammatory markers. In most cases saline treated animals showed few changes with CO2 exposure, though some changes in mRNA levels were present. This shows that CO2 as low as 1000 ppm CO2 was capable of altering innate immune responses to both LPS and organic dust extracts, but each response was altered in a different fashion.


2017 ◽  
Vol 49 (1) ◽  
pp. 73 ◽  
Author(s):  
Teguh Hariyanto ◽  
Trismono C. Krisna ◽  
Khomsin Khomsin ◽  
Cherie Bhekti Pribadi ◽  
Nadjadji Anwar

The decrease of coastal-water quality in the Surabaya coastal region can be recognized from the conceentration of Total Suspended Sediment(TSS ) . As a result we need a system for monitoring sediment concentration in the coastal region of Surabaya which regularly measures TSS. The principle to model and monitor TSSconcentration using remote sensing methods is by the integration of Landsat-8OLI satellites image processing using some ofTSS-models then those are analyzed for looking its suitability with TSS value direcly measured in the field ( in-situ measurement). The TSS value modeled from all algorithms validated usingcorrelation analysis and linear regression . The result shows that TSS model with the highest correlation value is TSS algorithm by Budiman (2004)with r value 0.991. Hence this algorithm can be used to investigate TSS-distribution which represent the coastal water quality of Surabaya with TSS value between 75 mg/L to 125 mg/L.


2021 ◽  
Vol 29 (1) ◽  
Author(s):  
Henry Munandar Manik ◽  
Randi Firdaus

Tidung Island, located near Jakarta Bay, is a tourism and conservation area. It is necessary to keep these seawaters unpolluted. To calculate the level of pollution, it is necessary to know the sediment concentration. Quantifying concentration suspended sediment is important for knowledge of sediment transport. Researchers usually use water sample analysis and optical method for quantifying suspended sediment in seawater. Less accuracies of these methods are due to under sample of seawater and the existence of biological fouling. One promising method to measure concentration of suspended sediment is using Acoustic Doppler Current Profiler (ADCP). ADCP is usually used by oceanographer and hydrographer to measure ocean current. In this research, ADCP with 300 kHz operating frequency was used effectively to measure suspended sediment concentration (SSC) and ocean current simultaneously. The echo intensity received from suspended sediment was computed using sonar equations to quantify SSC. The empirical equation between echo intensity and SSC was found. The SSC value obtained by ADCP was also compared with in situ measurement. The result showed that quantified SSC value obtained by ADCP was nearly equal with SSC obtained from in situ measurement with coefficient correlation of 0.98. The high concentration ranged from 55 mg/L to 80 mg/L at the surface layer to a depth 12 m, moderate concentration ranged from 45 mg/L to 55 mg/L at a depth 12 m to 40 m, and low concentration less than 45 mg/L at a depth greater than 40 m. The distribution of SSC was correlated with ocean current condition. In small currents, suspended solids will settle faster so that the concentration in the water column will decrease. Conversely, if the velocity is high, suspended solids will continue to float carried by the current in the water column so that the concentration is high.


2021 ◽  
Author(s):  
Dhruv Sehgal ◽  
Núria Martínez-Carreras ◽  
Christophe Hissler ◽  
Victor Bense ◽  
AJF (Ton) Hoitink

&lt;p&gt;Manual and unattended sampling in the field and laboratory analysis are common practices to measure suspended sediment (SS) carbon content and particle size. However, one of the major drawbacks of these ex-situ methods is that they make high frequency measurements challenging. This includes restricted data collection due to limited access to the sampling locations during turbulent conditions or high flows, when the largest amount of sediments is transported downstream, introducing uncertainty in quantification of SS properties (particle size and carbon content) and sediment loads. Knowledge on SS carbon content and particle size is also important to better understand the multi-component form of suspended sediments (i.e. flocs) that directly affect sediment transport and other sediment properties (e.g. settling velocity and density). Moreover, SS carbon content and particle size exert an impact on the optical sensor readings that are traditionally used to measure turbidity. In that respect, high frequency measurements of SS carbon content and particle size could eventually help us to move from &amp;#8216;local&amp;#8217; calibrations towards &amp;#8216;global&amp;#8217; dependencies based on in-situ SS characterization.&lt;/p&gt;&lt;p&gt;In this study, we propose to use a submerged UV-VIS spectrometer to infer SS carbon content and particle size. The sensor measures the entire light absorption spectrum of water between 200 nm and 750 nm at sampling intervals as short as 2-minutes. To this end, we first test our approach under controlled conditions with an experimental laboratory setup consisting of a cylindrical tank (40-L) with an open top. An UV-VIS spectrometer and a LISST-200X sensor (to measure particle size distribution) are installed horizontally. A stirrer facilitates the homogeneous mixing of SS and prevents the settling of heavy particles at the bottom. We use the sediments sampled from 6 sites in Luxembourg with contrasting composition and representing different land use types and geological settings. The sampled sediments were wet sieved into 3 size classes to clearly recognize the effect of particle size on absorption. In our investigation, we use specific wavelengths, chemometric techniques and carbon content specific absorbance indices to infer SS composition and particle size from the absorption spectrum. Results are then validated using in-situ field data from two instrumented field sites in Luxembourg. Amid the challenge of associating laboratory and field results, the preliminary results indicate that the absorption spectrum measured with a submerged UV-VIS spectrometer can be used to estimate SS particle size and carbon content.&lt;/p&gt;


Sign in / Sign up

Export Citation Format

Share Document