The Contribution of Environmental Scanning to Organisational Learning and Strategy Development

Author(s):  
Stephen Pilbeam ◽  
Juliet Osbourne
2014 ◽  
Vol 18 (03) ◽  
pp. 1440004 ◽  
Author(s):  
VICTORIA KAYSER ◽  
KERSTIN GOLUCHOWICZ ◽  
ANTJE BIERWISCH

Technology roadmapping is a well-established method used in strategy development to map alternative future paths, while text mining offers untapped potentials concerning early detection and environmental scanning. In this paper, the roadmapping process is split into different steps in order to analyse which text mining methods could add further value within each. This leads to a two-layered process model, which includes text mining techniques to systematically integrate external information in ongoing roadmapping processes. Textual data can be used for a structured analysis and exploration of thematic fields and an objective, quantitative summary of actual developments. To demonstrate some of the benefits, the field of "cloud computing" is used to illustrate the procedure. As this article will show, the results provided by this approach extend the existing methodology, integrates an external view and complements expert opinion.


Author(s):  
G.D. Danilatos

Over recent years a new type of electron microscope - the environmental scanning electron microscope (ESEM) - has been developed for the examination of specimen surfaces in the presence of gases. A detailed series of reports on the system has appeared elsewhere. A review summary of the current state and potential of the system is presented here.The gas composition, temperature and pressure can be varied in the specimen chamber of the ESEM. With air, the pressure can be up to one atmosphere (about 1000 mbar). Environments with fully saturated water vapor only at room temperature (20-30 mbar) can be easily maintained whilst liquid water or other solutions, together with uncoated specimens, can be imaged routinely during various applications.


Author(s):  
Howard S. Kaufman ◽  
Keith D. Lillemoe ◽  
John T. Mastovich ◽  
Henry A. Pitt

Gallstones contain precipitated cholesterol, calcium salts, and proteins. Calcium (Ca) bilirubinate, palmitate, phosphate, and carbonate occurring in gallstones have variable morphologies but characteristic windowless energy dispersive x-ray (EDX) spectra. Previous studies of gallstone microstructure and composition using scanning electron microscopy (SEM) with EDX have been limited to dehydrated samples. In this state, Ca bilirubinates appear as either glassy masses, which predominate in black pigment stones, or as clusters, which are found mostly in cholesterol gallstones. The three polymorphs of Ca carbonate, calcite, vaterite, and aragonite, have been identified in gallstones by x-ray diffraction, however; the morphologies of these crystals vary in the literature. The purpose of this experiment was to study fresh gallstones by environmental SEM (ESEM) to determine if dehydration affects gallstone Ca salt morphology.Gallstones and bile were obtained fresh at cholecystectomy from 6 patients. To prevent dehydration, stones were stored in bile at 37°C. All samples were studied within 4 days of procurement.


Author(s):  
Klaus-Ruediger Peters

Environmental SEM operate at specimen chamber pressures of ∼20 torr (2.7 kPa) allowing stabilization of liquid water at room temperature, working on rugged insulators, and generation of an environmental secondary electron (ESE) signal. All signals available in conventional high vacuum instruments are also utilized in the environmental SEM, including BSE, SE, absorbed current, CL, and X-ray. In addition, the ESEM allows utilization of the flux of charge carriers as information, providing exciting new signal modes not available to BSE imaging or to conventional high vacuum SEM.In the ESEM, at low vacuum, SE electrons are collected with a “gaseous detector”. This detector collects low energy electrons (and ions) with biased wires or plates similar to those used in early high vacuum SEM for SE detection. The detector electrode can be integrated into the first PLA or positioned at any other place resulting in a versatile system that provides a variety of surface information.


Author(s):  
G.D. Danilatos

The environmental scanning electron microscope (ESEM) has evolved as the natural extension of the scanning electron microscope (SEM), both historically and technologically. ESEM allows the introduction of a gaseous environment in the specimen chamber, whereas SEM operates in vacuum. One of the detection systems in ESEM, namely, the gaseous detection device (GDD) is based on the presence of gas as a detection medium. This might be interpreted as a necessary condition for the ESEM to remain operational and, hence, one might have to change instruments for operation at low or high vacuum. Initially, we may maintain the presence of a conventional secondary electron (E-T) detector in a "stand-by" position to switch on when the vacuum becomes satisfactory for its operation. However, the "rough" or "low vacuum" range of pressure may still be considered as inaccessible by both the GDD and the E-T detector, because the former has presumably very small gain and the latter still breaks down.


Author(s):  
S.A. Wight

Measurements of electrons striking the sample in the Environmental Scanning Electron Microscope (ESEM) are needed to begin to understand the effect of the presence of the gas on analytical measurements. Accurate beam current is important to x-ray microanalysis and it is typically measured with a faraday cup. A faraday cup (Figure 1) was constructed from a carbon block embedded in non-conductive epoxy with a 45 micrometer bore platinum aperture over the hole. Currents were measured with an electrometer and recorded as instrument parameters were varied.Instrument parameters investigated included working distance, chamber pressure, condenser percentage, and accelerating voltage. The conditions studied were low vacuum with gaseous secondary electron detector (GSED) voltage on; low vacuum with GSED voltage off; and high vacuum (GSED off). The base conditions were 30 kV, 667 Pa (5 Torr) water vapor, 100,000x magnification with the beam centered inside aperture, GSED voltage at 370 VDC, condenser at 50%, and working distance at 19.5 mm. All modifications of instrument parameters were made from these conditions.


2001 ◽  
Vol 7 (S2) ◽  
pp. 1276-1277
Author(s):  
Y. Akin ◽  
R.E. Goddard ◽  
W. Sigmund ◽  
Y.S. Hascicek

Deposition of highly textured ReBa2Cu3O7−δ (RBCO) films on metallic substrates requires a buffer layer to prevent chemical reactions, reduce lattice mismatch between metallic substrate and superconducting film layer, and to prevent diffusion of metal atoms into the superconductor film. Nickel tapes are bi-axially textured by cold rolling and annealing at appropriate temperature (RABiTS) for epitaxial growth of YBa2Cu3O7−δ (YBCO) films. As buffer layers, several oxide thin films and then YBCO were coated on bi-axially textured nickel tapes by dip coating sol-gel process. Biaxially oriented NiO on the cube-textured nickel tape by a process named Surface-Oxidation- Epitaxy (SEO) has been introduced as an alternative buffer layer. in this work we have studied in situ growth of nickel oxide by ESEM and hot stage.Representative cold rolled nickel tape (99.999%) was annealed in an electric furnace under 4% hydrogen-96% argon gas mixture at 1050°C to get bi-axially textured nickel tape.


Sign in / Sign up

Export Citation Format

Share Document