ESEM - A multipurpose surface Electron Microscope

Author(s):  
G.D. Danilatos

Over recent years a new type of electron microscope - the environmental scanning electron microscope (ESEM) - has been developed for the examination of specimen surfaces in the presence of gases. A detailed series of reports on the system has appeared elsewhere. A review summary of the current state and potential of the system is presented here.The gas composition, temperature and pressure can be varied in the specimen chamber of the ESEM. With air, the pressure can be up to one atmosphere (about 1000 mbar). Environments with fully saturated water vapor only at room temperature (20-30 mbar) can be easily maintained whilst liquid water or other solutions, together with uncoated specimens, can be imaged routinely during various applications.

1996 ◽  
Vol 11 (4) ◽  
pp. 288-289 ◽  
Author(s):  
H. Hashizume ◽  
S. Shimomura ◽  
H. Yamada ◽  
T. Fujita ◽  
H. Nakazawa ◽  
...  

A system enabling X-ray diffraction patterns under controlled conditions of relative humidity and temperature has been devised and combined with an X-ray powder diffractometer. Relative humidity in the sample space is controlled by mixing dry N2 gas with saturated water vapor. Temperatures of the sample and inner wall of the sample chamber are monitored by two attached thermocouples and the information was fed back to the control unit. Relative humidity between 0% and the 95%, and temperature between room temperature and 60 °C can be controlled. All parameters including those for XRD are programmable and the system runs automatically. The function of the system was checked by recording the XRD patterns of montmorillonite (a clay mineral) and NaCl under increasing and decreasing relative humidity.


1969 ◽  
Vol 22 (7) ◽  
pp. 1341 ◽  
Author(s):  
MW Anker ◽  
R Colton ◽  
CJ Rix ◽  
IB Tomkins

Compounds of the general formulae M(CO)3(dpe)X2, [M(CO)2(dpe)1.5X2]2, and M(CO)2(dpe)2X2 have been prepared and characterized (M = Mo, W; dpe = bis- (1,2-diphenylphosphino)ethane; X = Cl, Br, I). All of the compounds are diamagnetic and most of them are non-electrolytes. However, conductivity measurements indicate that, for the iodo derivatives only, the bis(dpe) compounds should be formulated as 1 : 1 electrolytes, [M(CO)2(dpe)2I]I. ��� For the iodo series of compounds only, there is a complex series of reversible reactions including a new type of carbon monoxide carrying system. In addition, the dimeric dpe derivatives are cleaved by carbon monoxide at room temperature and pressure to give equal quantities of [M(CO)2(dpe)2I]I and M(CO)3(dpe)I2.


2012 ◽  
Vol 190 ◽  
pp. 538-541
Author(s):  
V.E. Zubov ◽  
A.D. Kudakov ◽  
N.L. Levsнin ◽  
M.Yu. Gusev ◽  
N.S. Neustroev

Due to water molecules adsorption the reversible change of domains width and domain structure reconstruction in bismuth-doped ferrite-garnet thin films with perpendicular magnetic anisotropy was observed. The change of domains width was 15% in saturated water vapor at room temperature. The decrease of domains width is explained by the reduction of effective perpendicular magnetic anisotropy constant due to water molecules adsorption.


Author(s):  
S. Basu ◽  
D. F. Parsons

We are approaching the invasiveness of cancer cells from the studies of their wet surface morphology which should distinguish them from their normal counterparts. In this report attempts have been made to provide physical basis and background work to a wet replication method with a differentially pumped hydration chamber (Fig. 1) (1,2), to apply this knowledge for obtaining replica of some specimens of known features (e.g. polystyrene latex) and finally to realize more specific problems and to improvize new methods and instrumentation for their rectification. In principle, the evaporant molecules penetrate through a pair of apertures (250, 350μ), through water vapors and is, then, deposited on the specimen. An intermediate chamber between the apertures is pumped independently of the high vacuum system. The size of the apertures is sufficiently small so that full saturated water vapor pressure is maintained near the specimen.


Author(s):  
Louis T. Germinario

A liquid nitrogen stage has been developed for the JEOL JEM-100B electron microscope equipped with a scanning attachment. The design is a modification of the standard JEM-100B SEM specimen holder with specimen cooling to any temperatures In the range ~ 55°K to room temperature. Since the specimen plane is maintained at the ‘high resolution’ focal position of the objective lens and ‘bumping’ and thermal drift la minimized by supercooling the liquid nitrogen, the high resolution capability of the microscope is maintained (Fig.4).


Author(s):  
R. C. Moretz ◽  
G. G. Hausner ◽  
D. F. Parsons

Use of the electron microscope to examine wet objects is possible due to the small mass thickness of the equilibrium pressure of water vapor at room temperature. Previous attempts to examine hydrated biological objects and water itself used a chamber consisting of two small apertures sealed by two thin films. Extensive work in our laboratory showed that such films have an 80% failure rate when wet. Using the principle of differential pumping of the microscope column, we can use open apertures in place of thin film windows.Fig. 1 shows the modified Siemens la specimen chamber with the connections to the water supply and the auxiliary pumping station. A mechanical pump is connected to the vapor supply via a 100μ aperture to maintain steady-state conditions.


Author(s):  
V. R. Matricardi ◽  
G. G. Hausner ◽  
D. F. Parsons

In order to observe room temperature hydrated specimens in an electron microscope, the following conditions should be satisfied: The specimen should be surrounded by water vapor as close as possible to the equilibrium vapor pressure corresponding to the temperature of the specimen.The specimen grid should be inserted, focused and photo graphed in the shortest possible time in order to minimize dehydration.The full area of the specimen grid should be visible in order to minimize the number of changes of specimen required.There should be no pressure gradient across the grid so that specimens can be straddled across holes.Leakage of water vapor to the column should be minimized.


Author(s):  
W. P. Wergin ◽  
S. Roy ◽  
E. F. Erbe ◽  
C. A. Murphy ◽  
C. D. Pooley

Larvae of the nematode, Steinernema carpocapsae Weiser strain All, were cryofixed and freezesubstituted for 3 days in acetone containing 2% osmium tetroxide according to established procedures. Following chemical fixation, the nematodes were brought to room temperature, embedded in Spurr's medium and sectioned for observation with a Hitachi S-4100 field emission scanning electron microscope that was equipped with an Oxford CT 1500 Cryotrans System. Thin sections, about 80 nm thick, similar to those generally used in conventional transmission electron microscope (TEM) studies were mounted on copper grids and stained with uranyl acetate for 30 min and lead citrate for 5 min. Sections about 2 μm thick were also mounted and stained in a similar fashion. The grids were mounted on an Oxford grid holder, inserted into the microscope and onto a cryostage that was operated at ambient temperature. Thick and thin sections of the larvae were evaluated and photographed in the SEM at different accelerating voltages. Figs. 4 and 5 have undergone contrast conversion so that the images would resemble transmitted electron micrographs obtained with a TEM.


Author(s):  
H. Weiland ◽  
D. P. Field

Recent advances in the automatic indexing of backscatter Kikuchi diffraction patterns on the scanning electron microscope (SEM) has resulted in the development of a new type of microscopy. The ability to obtain statistically relevant information on the spatial distribution of crystallite orientations is giving rise to new insight into polycrystalline microstructures and their relation to materials properties. A limitation of the technique in the SEM is that the spatial resolution of the measurement is restricted by the relatively large size of the electron beam in relation to various microstructural features. Typically the spatial resolution in the SEM is limited to about half a micron or greater. Heavily worked structures exhibit microstructural features much finer than this and require resolution on the order of nanometers for accurate characterization. Transmission electron microscope (TEM) techniques offer sufficient resolution to investigate heavily worked crystalline materials.Crystal lattice orientation determination from Kikuchi diffraction patterns in the TEM (Figure 1) requires knowledge of the relative positions of at least three non-parallel Kikuchi line pairs in relation to the crystallite and the electron beam.


Author(s):  
G.D. Danilatos

The environmental scanning electron microscope (ESEM) has evolved as the natural extension of the scanning electron microscope (SEM), both historically and technologically. ESEM allows the introduction of a gaseous environment in the specimen chamber, whereas SEM operates in vacuum. One of the detection systems in ESEM, namely, the gaseous detection device (GDD) is based on the presence of gas as a detection medium. This might be interpreted as a necessary condition for the ESEM to remain operational and, hence, one might have to change instruments for operation at low or high vacuum. Initially, we may maintain the presence of a conventional secondary electron (E-T) detector in a "stand-by" position to switch on when the vacuum becomes satisfactory for its operation. However, the "rough" or "low vacuum" range of pressure may still be considered as inaccessible by both the GDD and the E-T detector, because the former has presumably very small gain and the latter still breaks down.