Experimental Evaluation of Bearing Capacity of Multifaceted Pipes Filled with Self-compacting Concrete Under Axial Compression

Author(s):  
Igor Garanzha ◽  
Liliya Shchykina ◽  
Farida Suyunova
2012 ◽  
Vol 204-208 ◽  
pp. 1066-1069
Author(s):  
Yan Jun Li ◽  
Ping Liu

Four specially shaped columns with HRB500 reinforcement were tested under low cyclic loading. The hysteretic curve, yield load, ultimate load, displacement ductility and rigidity degradation were compared in order to research the effect of axial compression ratio on ductility and bearing capacity of specially shaped column with HRB500 reinforcement. It is shown that the axial compression ratio has greater influence on ductility and bearing capacity. With the increase of axial compression ratio, the bearing capacity of HRB500 reinforcement concrete specially shaped column can be enhanced while the deformation capacity becomes worse. The hysteretic characteristic of specially shaped columns with HRB500 reinforcement is improved and the stiffness degeneration becomes slow with the decrease of axial compression ratio.


2014 ◽  
Vol 1079-1080 ◽  
pp. 177-182
Author(s):  
Shao Wu Zhang ◽  
Ying Chuan Chen ◽  
Geng Biao Zhang

In order to study the performance of concrete frame columns that reinforcedby assembleinclined web steel truss, with the same reciprocatinghorizontal displacement and different axialcompression.It canbe calculate the mechanical behavior of concrete frame columns and reinforced columns by using the finite element analysis software ABAQUS. Simulation analysis shows that the bearing capacity ofreinforced columnshas greatly increased andpresented a full hysteresis curve. The result shows that the reinforcement method of assemble inclined web steel truss can greatly improve the bearing capacity and ductility of the concrete frame column, and the axial compression is larger, the better the reinforcement effect.


Polymers ◽  
2021 ◽  
Vol 13 (23) ◽  
pp. 4267
Author(s):  
Qi Ye ◽  
Yingchun Gong ◽  
Haiqing Ren ◽  
Cheng Guan ◽  
Guofang Wu ◽  
...  

Cross-laminated timber (CLT) elements are becoming increasingly popular in multi-storey timber-based structures, which have long been built in many different countries. Various challenges are connected with constructions of this type. One such challenge is that of stabilizing the structure against vertical loads. However, the calculations of the stability bearing capacity of the CLT members in axial compression in the structural design remains unsolved in China. This study aims to determine the stability bearing capacity of the CLT members in axial compression and to propose the calculation method of the stability coefficient. First, the stability coefficient calculation theories in different national standards were analyzed, and then the stability bearing capacity of CLT elements with four slenderness ratios was investigated. Finally, based on the stability coefficient calculation formulae in the GB 50005-2017 standard and the regression method, the calculation method of the stability coefficient for CLT elements was proposed, and the values of the material parameters were determined. The result shows that the average deviation between fitting curve and calculated results of European and American standard is 5.43% and 3.73%, respectively, and the average deviation between the fitting curve and the actual test results was 8.15%. The stability coefficients calculation formulae could be used to predict the stability coefficients of CLT specimens with different slenderness ratios well.


2021 ◽  
Vol 2021 ◽  
pp. 1-17
Author(s):  
Dafu Cao ◽  
Jiaqi Liu ◽  
Wenjie Ge ◽  
Rui Qian

In order to study the influence of the axial compression ratio and steel ratio on the shear-carrying capacity of steel-truss-reinforced beam-column joints, five shear failure interior joint specimens were designed. The effect of different coaxial pressure ratios (0.1, 0.2, and 0.3) and steel contents on the strain, ultimate bearing capacity, seismic performance, and failure pattern of cross-inclined ventral and chord bars in the joint core area was investigated. The experimental results show that the load-displacement hysteretic curves of all test specimens exhibit a bond-slip phenomenon. With the increase of the axial compression ratio, the ultimate bearing capacity of the joint core increases by 3.4% and 5.9%, respectively. While the ductility decreases by 10.3% and 13.1%, and the energy consumption capacity decreases by 3.2% and 5.8%, respectively. The shear capacity and ductility of the member with cross diagonal ventral steel angle in the joint core are increased by 12.9% and 13.4%, respectively. The shear capacity and ductility of the joint can be significantly improved by increasing the amount of steel in the core area. The expression of shear capacity suitable for this type of joint is obtained by fitting analysis, which can be used as a reference for engineering design.


2011 ◽  
Vol 368-373 ◽  
pp. 248-252
Author(s):  
Bao Sheng Yang ◽  
Yun Yun Li

The influence on columns behaviors of slenderness ratio are analyzed, and the influence on columns’ anti-seismic behavior of axial compression ratio, stirrup ratio and steel form are analyzed through the test on bearing capacity and level load of low cycle reverse of steel reinforced high-strength concrete columns. The bearing capacity of the long columns reduces along with the slenderness ratio increasing and augments along with concrete strength increasing. Probability of suddenly destruct increases along with the column slenderness ratio augmenting through the test. In addition, anti-seismic behavior of columns are effected not only axial compression ratio, but also steel form. Axial compression coefficien of the steel reinforced high-strength concrete columns with different steel form may be adjusted, however, the influence of stirrup ratio is very little on anti-seismic behavior of columns.


2016 ◽  
Vol 2016 ◽  
pp. 1-11
Author(s):  
Hua Huang ◽  
Kailin Xi ◽  
Yu Zhang ◽  
Jinghui Shi ◽  
Boquan Liu

The load carrying capacity and failure mechanism of 8 square columns strengthened with high-performance ferrocement laminate (HPFL) and bonded steel plates (BSP) were analyzed on the basis of experiments on the axial compression performance of these columns. Results show that the reinforcing layer worked together with the original columns as a whole, and the load-bearing capacity significantly increased. When failure of the strengthened column occurred, the mortar and concrete were crushed and bulged outward in the middle of the columns, the angle bars and longitudinal steel bars buckled, and some stirrups were pulled out. The chamfering of angle bar momentously affected the primary damage of steel strand. The values of the strength reduction factor and pressure effective utilization coefficient of the mortar were suggested. Based on the experiments and existing tests of 35 columns strengthened with HPFL, equations for the axial compression bearing capacity were proposed and all calculation results agreed well with testing results. Therefore, the calculation method could be used in the capacity design of axial compression strengthened columns.


Sign in / Sign up

Export Citation Format

Share Document