Magnetic Measurements of Solid Material

Author(s):  
Tomas Bulin ◽  
Cestmir Ondrusek
Author(s):  
P.G. Pawar ◽  
P. Duhamel ◽  
G.W. Monk

A beam of ions of mass greater than a few atomic mass units and with sufficient energy can remove atoms from the surface of a solid material at a useful rate. A system used to achieve this purpose under controlled atmospheres is called an ion miliing machine. An ion milling apparatus presently available as IMMI-III with a IMMIAC was used in this investigation. Unless otherwise stated, all the micro milling operations were done with Ar+ at 6kv using a beam current of 100 μA for each of the two guns, with a specimen tilt of 15° from the horizontal plane.It is fairly well established that ion bombardment of the surface of homogeneous materials can produce surface topography which resembles geological erosional features.


Author(s):  
J. R. Sellar ◽  
J. M. Cowley

Current interest in high voltage electron microscopy, especially in the scanning mode, has prompted the development of a method for determining the contrast and resolution of images of specimens in controlled-atmosphere stages or open to the air, hydrated biological specimens being a good example. Such a method would be of use in the prediction of microscope performance and in the subsequent optimization of environmental cell design for given circumstances of accelerating voltage, cell gas pressure and constitution, and desired resolution.Fig. 1 depicts the alfresco cell of a focussed scanning transmission microscope with a layer of gas L (and possibly a thin window W) between the objective O and specimen T. Using the principle of reciprocity, it may be considered optically equivalent to a conventional transmission electron microscope, if the beams were reversed. The layer of gas or solid material after the specimen in the STEM or before the specimen in TEM has no great effect on resolution or contrast and so is ignored here.


2020 ◽  
pp. 3-7
Author(s):  
Vladlen Ya. Shifrin ◽  
Denis I. Belyakov ◽  
Alexander E. Shilov ◽  
Denis D. Kosenko

The results of works aimed at increasing the level of uniformity of measurements of the magnetic induction of a constant field – the basic value in the field of magnetic measurements. A set of equipment for reproducing a unit of magnetic induction of a constant field in the range of 1–25 mT was created and described. The inclusion of this complex in the State primary standard of units of magnetic induction, magnetic flux, magnetic moment and magnetic induction gradient GET 12-2011 will ensure the reproduction and direct transmission of the unit of permanent magnetic induction in the ranges of not only weak (10–3–1 mT), but medium (1–25 mT) and strong (0.025–1 T) magnetic fields. A quantum cesium magnetometer based on the resolved structure of cesium atoms was created to transmit the unit of magnetic induction to the region of medium fields. The procedure for calculating the frequency conversion coefficients to magnetic induction of the created quantum cesium magnetometer is described. The uncertainty budget for reproducing a unit of magnetic induction of a constant field using the created complex is estimated.


2016 ◽  
pp. 3524-3528
Author(s):  
Casey Ray McMahon

In this paper, I discuss the theory behind the use of a dense, concentrated neutron particle-based beam. I look at the particle based physics behind such a beam, when it is focused against solid material matter. Although this idea is still only theoretical, it appears that such a beam may be capable of disrupting the stability of the atoms within solid matter- in some cases by passing great volumes of neutrons between the electron and nucleus thus effectively “shielding” the electron from the charge of the nucleus. In other cases, by disrupting the nucleus by firing neutrons into it, disrupting the nucleus and weakening its bond on electrons. In either case- the resulting effect would be a disruption of the atom, which in the case of material matter would cause said material matter to fail, which would appear to the observer as liquification with some plasma generation. Thus, a dense neutron particle based beam could be used to effectively liquefy material matter. Such a beam could bore through rock, metal, or even thick, military grade armour, like that used on tanks- causing such materials to rapidly liquefy. The denser and thicker the neutron beam, the more devastating the effect of the beam- thus the faster material matter will liquefy and the greater the area of liquification. Such a beam would have applications in Defence, mining and drilling operations.


2020 ◽  
Vol 84 (11) ◽  
pp. 1354-1358
Author(s):  
Yu. V. Maslennikov ◽  
V. Yu. Slobodchikov ◽  
V. A. Krymov ◽  
A. D. Sukhodrovsky ◽  
Yu. V. Gulyaev

2020 ◽  
pp. 409-432
Author(s):  
Oskar Kubrak ◽  
Paulina Kubrak ◽  
Mkrtich H. Zardaryan

During the last years of Emperor Trajan’s reign, the Legio IV Scythica was stationed in the capital of Armenia at that time, Artaxata. It had made its way there within the scope of the Roman campaign against the Parthians. Its presence was immortalised on stamped rooftiles, bricks and a monumental inscription discovered by the southern border of the present-day village of Pokr Vedi. The inscription carved into limestone confirms the building activities of the Roman army. Similar inscriptions were frequently placed on the gates and most important buildings in legionary camps. Polish and Armenian archaeologists undertook a joint search for the supposed camp of the Fourth Scythian Legion in the vicinity of the present-day village of Pokr Vedi, where the above-mentioned construction inscription had been found. The field surveys conducted within the framework of the Pokr Vedi Project were mainly of a non-invasive character. The following were applied: surface prospection, aerial photography, interviews with the inhabitants, scanning of part of the terrain and geophysical measurements done using two methods: electrical resistivity and magnetic measurements. The accumulated data enabled the selection of sites in which survey trenches were located


Author(s):  
Thorkild M. Rasmussen

NOTE: This article was published in a former series of GEUS Bulletin. Please use the original series name when citing this article. Rasmussen, T. M. (1). Aeromagnetic survey in central West Greenland: project Aeromag 2001. Geology of Greenland Survey Bulletin, 191, 67-72. https://doi.org/10.34194/ggub.v191.5130 The series of government-funded geophysical surveys in Greenland was continued during the spring and summer of 2001 with a regional aeromagnetic survey north of Uummannaq, project Aeromag 2001 (Fig. 1). The survey added about 70 000 line kilometres of high-quality magnetic measurements to the existing database of modern airborne geophysical data from Greenland. This database includes both regional high-resolution aeromagnetic surveys and detailed surveys with combined electromagnetic and magnetic airborne measurements.


10.2172/3965 ◽  
1999 ◽  
Author(s):  
Robert C. Trendler and Walter F. Jaskierny