scholarly journals A Comparison of Surface Tension, Viscosity, and Density of Sn and Sn–Ag Alloys Using Different Measurement Techniques

2011 ◽  
Vol 32 (6) ◽  
pp. 1210-1233 ◽  
Author(s):  
Tomasz Gancarz ◽  
Zbigniew Moser ◽  
Władysław Gąsior ◽  
Janusz Pstruś ◽  
Hani Henein
Holzforschung ◽  
2001 ◽  
Vol 55 (1) ◽  
pp. 21-32 ◽  
Author(s):  
M.E.P. Wålinder ◽  
I. Johansson

Summary This work focuses on the influence of extractives during wetting measurements on wood. Fresh and aged veneers of extracted and non-extracted heart- and sapwood of pine were prepared, and the Wilhelmy method was used to study the wettability of these veneers. In this method, the force acting on the veneers was measured during immersion in and withdrawal from a series of probe liquids. The results suggest that some of the probe liquids become severely contaminated by extractives during the measurements on the non-extracted veneers, and that this strongly affects the wood wetting measurements. The contamination is effectively detected as a distinct decrease in the surface tension of the liquids caused by dissolution or presence of wood extractives at the wood-liquid interface. It is important to note that such contamination may also occur during wetting studies on wood using other contact angle measurement techniques. The most obvious contamination occurred in the case of measurements on non-extracted veneers immersed in water and formamide. Generally, no contamination was detected in the case of measurements on extracted wood veneers. The Wilhelmy method may provide an efficient means for recording and control of any contamination of the probe liquids that may arise during wetting studies on wood.


Author(s):  
J. L. Perez-Diaz ◽  
M. A. Alvarez-Valenzuela ◽  
I. Valiente-Blanco ◽  
S. Jimenez-Lopez ◽  
M. Palacios-Cuesta ◽  
...  

Contact angle analysis of liquids on surfaces has been extensively used to evaluating solid surface free energy, surface tension, and surface wetting characteristics. Despite the great interest in the contact angle, reported measurements has shown a high variety, which is often related to different contact angle measurement techniques or substrate preparation and oxidation among others. In addition, it is well know, that surface tension and contact angle are modified with temperature. However, no attention has been paid to the influence of the relative humidity (RH) in surface tension or contact angle measurements. In a previous work, we have demonstrated that (for a constant temperature) surface tension on a suspended droplet decreases linearly with RH in the air. In this paper, contact angle of a water droplet on a silicon wafer surface is studied and its relationship with the relative humidity in the air investigated.


2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Samia A. Kosa ◽  
Laila M. Al-Harbi ◽  
Musa Kaleem Baloch ◽  
Irfan Ullah ◽  
Elsayed H. El-Mossalamy

Self-assembling behavior of block copolymers having water-soluble portion as one of the blocks plays key role in the properties and applications of the copolymers. Therefore, we have synthesized block copolymers of different block length and investigated their self-assembling behavior with reference to concentration and temperature using surface tension and conductance measurement techniques. The results obtained through both techniques concluded that critical micelles concentration (CMC) was decreased from 0.100 to 0.078 g/dL with the increase in length of water insoluble block and 0.100 to 0.068 g/dL for the increased temperature.ΔGmicwas also decreased with the increase in temperature of the system, concluding that the micellization process was encouraged with the increase in temperature and block length. However,ΔHmicvalues were highest for short block length copolymer. The surface excess concentration obtained from surface tension data concluded that it was highest for short block length and vice versa and was increased with the increase in temperature of the system. However, the minimum area per molecule was largest for highest molecular weight copolymers or having longest water insoluble block and decreases with the increase in temperature.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Zhenglong Chen ◽  
Ming Zhong ◽  
Yuzhou Luo ◽  
Linhong Deng ◽  
Zhaoyan Hu ◽  
...  

AbstractBy airway surface liquid, we mean a thin fluid continuum consisting of the airway lining layer and the alveolar lining layer, which not only serves as a protective barrier against foreign particles but also contributes to maintaining normal respiratory mechanics. In recent years, measurements of the rheological properties of airway surface liquid have attracted considerable clinical attention due to new advances in microrheology instruments and methods. This article reviews the clinical relevance of measurements of airway surface liquid viscoelasticity and surface tension from four main aspects: maintaining the stability of the airways and alveoli, preventing ventilator-induced lung injury, optimizing surfactant replacement therapy for respiratory syndrome distress, and characterizing the barrier properties of airway mucus to improve drug and gene delivery. Primary measuring techniques and methods suitable for determining the viscoelasticity and surface tension of airway surface liquid are then introduced with respect to principles, advantages and limitations. Cone and plate viscometers and particle tracking microrheometers are the most commonly used instruments for measuring the bulk viscosity and microviscosity of airway surface liquid, respectively, and pendant drop methods are particularly suitable for the measurement of airway surface liquid surface tension in vitro. Currently, in vivo and in situ measurements of the viscoelasticity and surface tension of the airway surface liquid in humans still presents many challenges.


1975 ◽  
Vol 26 ◽  
pp. 87-92
Author(s):  
P. L. Bender

AbstractFive important geodynamical quantities which are closely linked are: 1) motions of points on the Earth’s surface; 2)polar motion; 3) changes in UT1-UTC; 4) nutation; and 5) motion of the geocenter. For each of these we expect to achieve measurements in the near future which have an accuracy of 1 to 3 cm or 0.3 to 1 milliarcsec.From a metrological point of view, one can say simply: “Measure each quantity against whichever coordinate system you can make the most accurate measurements with respect to”. I believe that this statement should serve as a guiding principle for the recommendations of the colloquium. However, it also is important that the coordinate systems help to provide a clear separation between the different phenomena of interest, and correspond closely to the conceptual definitions in terms of which geophysicists think about the phenomena.In any discussion of angular motion in space, both a “body-fixed” system and a “space-fixed” system are used. Some relevant types of coordinate systems, reference directions, or reference points which have been considered are: 1) celestial systems based on optical star catalogs, distant galaxies, radio source catalogs, or the Moon and inner planets; 2) the Earth’s axis of rotation, which defines a line through the Earth as well as a celestial reference direction; 3) the geocenter; and 4) “quasi-Earth-fixed” coordinate systems.When a geophysicists discusses UT1 and polar motion, he usually is thinking of the angular motion of the main part of the mantle with respect to an inertial frame and to the direction of the spin axis. Since the velocities of relative motion in most of the mantle are expectd to be extremely small, even if “substantial” deep convection is occurring, the conceptual “quasi-Earth-fixed” reference frame seems well defined. Methods for realizing a close approximation to this frame fortunately exist. Hopefully, this colloquium will recommend procedures for establishing and maintaining such a system for use in geodynamics. Motion of points on the Earth’s surface and of the geocenter can be measured against such a system with the full accuracy of the new techniques.The situation with respect to celestial reference frames is different. The various measurement techniques give changes in the orientation of the Earth, relative to different systems, so that we would like to know the relative motions of the systems in order to compare the results. However, there does not appear to be a need for defining any new system. Subjective figures of merit for the various system dependon both the accuracy with which measurements can be made against them and the degree to which they can be related to inertial systems.The main coordinate system requirement related to the 5 geodynamic quantities discussed in this talk is thus for the establishment and maintenance of a “quasi-Earth-fixed” coordinate system which closely approximates the motion of the main part of the mantle. Changes in the orientation of this system with respect to the various celestial systems can be determined by both the new and the conventional techniques, provided that some knowledge of changes in the local vertical is available. Changes in the axis of rotation and in the geocenter with respect to this system also can be obtained, as well as measurements of nutation.


Author(s):  
K. T. Tokuyasu

During the past investigations of immunoferritin localization of intracellular antigens in ultrathin frozen sections, we found that the degree of negative staining required to delineate u1trastructural details was often too dense for the recognition of ferritin particles. The quality of positive staining of ultrathin frozen sections, on the other hand, has generally been far inferior to that attainable in conventional plastic embedded sections, particularly in the definition of membranes. As we discussed before, a main cause of this difficulty seemed to be the vulnerability of frozen sections to the damaging effects of air-water surface tension at the time of drying of the sections.Indeed, we found that the quality of positive staining is greatly improved when positively stained frozen sections are protected against the effects of surface tension by embedding them in thin layers of mechanically stable materials at the time of drying (unpublished).


Sign in / Sign up

Export Citation Format

Share Document