Stall Behaviour in a Mixed-flow Compressor with Axial Slot Casing Treatment

2022 ◽  
Vol 31 (1) ◽  
pp. 13-24
Author(s):  
Jiahui Qiu ◽  
Qianfeng Zhang ◽  
Min Zhang ◽  
Juan Du ◽  
Wenqiang Zhang ◽  
...  
2020 ◽  
Vol 107 ◽  
pp. 106262
Author(s):  
Dun Ba ◽  
Qianfeng Zhang ◽  
Juan Du ◽  
Zhihui Li ◽  
Hongwu Zhang ◽  
...  

Author(s):  
Juan Du ◽  
Felix Kauth ◽  
Jichao Li ◽  
Qianfeng Zhang ◽  
Joerg R. Seume

Abstract This paper aims at experimentally demonstrating the effects of axial slot casing treatment and tip gap variation on compressor performance, unsteady tip clearance flow, and stall inception features in a highly-loaded mixed-flow compressor at partspeed. Two tip gaps (0.32% and 0.64% of rotor blade chord at mid-span) were tested at three rotational speeds. A semicircular axial slot casing treatment improves compressor stability. The experimental results show that this casing treatment significantly moves the stability limit at partial speeds towards lower mass flow for both tip gaps, compared to the reference case without casing treatment. In the case of the compressor with casing treatment, efficiency increases for the large tip gap and decreases for the small tip gap. Dynamic pressure transducers installed in the casing upstream and along the rotor tip chord direction are used to detect the unsteady behavior of tip region flow and stall inception signals of the compressor. The characteristic frequency in the tip region decreases, and the oscillating amplitude first decreases and then increases during the throttling process, regardless of tip gap size or casing treatment. For axial compressors, by contrast, the observation in previous work has been an increase of the oscillating amplitude with decreasing flow coefficient. This is a surprising result of our work. Neither experiment nor CFD so far was able to explain why the trend in this mixed-flow compressor is different from the trend expected from axial compressors. The compressor stalls through the spike stall inception both with and without casing treatment. This observation also differs from recent studies on axial compressors, which demonstrated that casing treatments could change the type of stall inception. The unstable disturbance indicating initial stall inception initially appears in the blade tip region from blade mid-chord to trailing edge, and then propagates upstream towards the leading edge. This disturbance might be generated by the reversed flow separation near mid-chord.


Author(s):  
Juan Du ◽  
Joerg R. Seume

Casing treatments (CTs) have been proved to beneficially affect the behavior of tip clearance flow and compressor stability. This paper presents the design of casing treatment for a mixed-flow compressor with a very small tip gap of 0.1mm. In the first part, the potential of applying two traditional types of casing treatments, i.e. circumferential grooves and axial slots, to enhance the stability of a mixed-flow compressor is investigated. The flow details in the reference compressor with smooth casing are examined first. It is found that a separating vortex is formed due to the reversed flow on the blade suction side near the rotor trailing edge at the near-stall point. It is supposed to be responsible for the decrease in total pressure ratio when the compressor approaches to stall. The numerical stall, i.e. the breakdown of the simulation, is initiated from the spillage of tip leakage flow over the rotor blade leading edge. The effect of circumferential grooves on the compressor performances is not remarkable. The implement of axial slots ameliorates the total pressure ratio and extend the flow range substantially, but with higher efficiency penalty than the circumferential grooves. The recirculation formed in the axial skewed slots eliminates the separation vortex near the trailing edge and suppresses the spillage of the tip leakage flow forward the rotor leading edge simultaneously. The axial skewed slots are further designed and optimized numerically by DoE (Design of Experiments). As DoE factors the axial length, the height, the open area ratio, and the number per blade passage of the slots are varied. Their effects on the two target values stall margin and polytropic efficiency are investigated. The plot of stall margin improvement (SMI) with a function of the peak efficiency improvement (PEI) indicates that the SMI changes reversely with the PE. There are two trends in the correlation curves of SMI with PE. For the configurations with the open area ratio of 20%, the SMI is changed from 9% to 23% with 1% decrease in PE by varying other three factors. For the CTs with the open area ratio of 60% the augment in SMI from 17.8% to 26.3% produces extra efficiency loss of 4.2%.


2019 ◽  
Vol 28 (5) ◽  
pp. 915-928 ◽  
Author(s):  
Qianfeng Zhang ◽  
Juan Du ◽  
Zhihui Li ◽  
Jichao Li ◽  
Hongwu Zhang

Author(s):  
Quentin Dejour ◽  
Huu Duc Vo

This paper presents the first assessment of a new non-axial counter-rotating compressor concept. This concept consists of replacing the stator of a mixed-flow compressor stage or the diffuser of a centrifugal compressor stage with a counter-rotating rotor that will turn the flow back to the axial direction with much lower diffusion factor, while providing the equivalent in work of the upstream mixed-flow rotor or impeller. This concept has two advantages. First, the very high stage pressure rise means that only a single counter-rotating rotor may be required, making mechanical implementation simpler than for multi-stage axial counter-rotating compressors. Second, the replacement of the high flow turning (high loss) stator/diffuser in a non-axial stage with a low flow turning counter-rotating rotor gives the new concept potential for achieving higher efficiency than conventional non-axial compressors. As a first proof of concept, a subsonic counter-rotating mixed-flow compressor and its conventional (i.e. rotor-stator) equivalent have been designed with the intent of being implemented in a test rig. CFD simulations have been carried out for a comparative evaluation of both configurations. Results show that the counter-rotating mixed-flow compressor produces more than double the pressure rise of its conventional version with a slightly higher peak-efficiency while having a smaller axial length. Moreover, the counter-rotating configuration has a better stall margin than its conventional counterpart, for which the boundary layer separation from excessive flow turning in the stator causes early stall.


Author(s):  
Xingen Lu ◽  
Junqiang Zhu ◽  
Chaoqun Nie ◽  
Weiguang Huang

The phenomenon of flow instability in the compression system such as fan and compressor has been a long-standing “bottle-neck” problem for gas turbines/aircraft engines. With a vision of providing a state-of-the-art understanding of the flow field in axial-flow compressor in the perspective of enhancing their stability using passive means. Two topics are covered in this paper. The first topic is the stability-limiting flow mechanism close to stall, which is the basic knowledge needed to manipulate end-wall flow behavior for the stability improvement. The physical process occurring when approaching stall and the role of complex tip flow mechanism on flow instability in current high subsonic axial compressor rotor has been assessed using single blade passage computations. The second topic is flow instability manipulation with casing treatment. In order to advance the understanding of the fundamental mechanisms of casing treatment and determine the change in the flow field by which casing treatment improve compressor stability, systematic studies of the coupled flow through a subsonic compressor rotor and various end-wall treatments were carried out using a state-of-the-art multi-block flow solver. The numerically obtained flow fields were interrogated to identify complicated flow phenomenon around and within the end-wall treatments and describe the interaction between the rotor tip flow and end-wall treatments. Detailed analyses of the flow visualization at the rotor tip have exposed the different tip flow topologies between the cases with treatment casing and with untreated smooth wall. It was found that the primary stall margin enhancement afforded by end-wall treatments is a result of the tip flow manipulation. Compared to the smooth wall case, the treated casing significantly dampen or absorb the blockage near the upstream part of the blade passage caused by the upstream movement of tip clearance flow and weakens the roll-up of the core vortex. These mechanisms prevent an early spillage of low momentum fluid into the adjacent blade passage and delay the onset of flow instability.


Sign in / Sign up

Export Citation Format

Share Document