Determination of Pear Internal Quality Attributes by Fourier Transform Near Infrared (FT-NIR) Spectroscopy and Multivariate Analysis

2012 ◽  
Vol 6 (2) ◽  
pp. 569-577 ◽  
Author(s):  
Hui Jiang ◽  
Weixing Zhu
2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Mohd Yusop Nurida ◽  
Dolmat Norfadilah ◽  
Mohd Rozaiddin Siti Aishah ◽  
Chan Zhe Phak ◽  
Syafiqa M. Saleh

The analytical methods for the determination of the amine solvent properties do not provide input data for real-time process control and optimization and are labor-intensive, time-consuming, and impractical for studies of dynamic changes in a process. In this study, the potential of nondestructive determination of amine concentration, CO2 loading, and water content in CO2 absorption solvent in the gas processing unit was investigated through Fourier transform near-infrared (FT-NIR) spectroscopy that has the ability to readily carry out multicomponent analysis in association with multivariate analysis methods. The FT-NIR spectra for the solvent were captured and interpreted by using suitable spectra wavenumber regions through multivariate statistical techniques such as partial least square (PLS). The calibration model developed for amine determination had the highest coefficient of determination (R2) of 0.9955 and RMSECV of 0.75%. CO2 calibration model achieved R2 of 0.9902 with RMSECV of 0.25% whereas the water calibration model had R2 of 0.9915 with RMSECV of 1.02%. The statistical evaluation of the validation samples also confirmed that the difference between the actual value and the predicted value from the calibration model was not significantly different and acceptable. Therefore, the amine, CO2, and water models have given a satisfactory result for the concentration determination using the FT-NIR technique. The results of this study indicated that FT-NIR spectroscopy with chemometrics and multivariate technique can be used for the CO2 solvent monitoring to replace the time-consuming and labor-intensive conventional methods.


BioResources ◽  
2020 ◽  
Vol 15 (2) ◽  
pp. 3006-3016
Author(s):  
Jing Huang ◽  
Chongwen Yu

Linen/viscose blended yarns provide unique properties, but the quality and cost of the fabric composed of the blended yarns are affected by the amount of linen fibers. The existing methods of detecting blending ratio are microscopy or specific component dissolution, which is time-consuming and inconvenient. This study considers the possibility of rapid and simple determination of linen content by the near infrared (NIR) method. A set of linen/viscose powdered blends with 11 different ratios was fabricated. For each sample, 10 sets of spectra were collected by Fourier transform (FT)-NIR spectrometer. A total of 110 spectra sets were generated, in which 60 were used for calibration and 50 for validation. There were verified differences in NIR peaks assigning to representative chemical bonds in cellulose. With the chemometric analysis, a partial least squares (PLS) model was established to predict the linen content in a blended sample. With a combination of smoothing, baseline offset, and multiplicative scatter correction processing of the spectral data, the established PLS model was further improved to achieve a standard validation error of only 1.182% and SD value of the predicted linen content less than 0.2, which indicated the accuracy of the developed method.


2021 ◽  
Vol 11 (7) ◽  
pp. 3209
Author(s):  
Karla R. Borba ◽  
Didem P. Aykas ◽  
Maria I. Milani ◽  
Luiz A. Colnago ◽  
Marcos D. Ferreira ◽  
...  

Portable spectrometers are promising tools that can be an alternative way, for various purposes, of analyzing food quality, such as monitoring in a few seconds the internal quality during fruit ripening in the field. A portable/handheld (palm-sized) near-infrared (NIR) spectrometer (Neospectra, Si-ware) with spectral range of 1295–2611 nm, equipped with a micro-electro-mechanical system (MEMs), was used to develop prediction models to evaluate tomato quality attributes non-destructively. Soluble solid content (SSC), fructose, glucose, titratable acidity (TA), ascorbic, and citric acid contents of different types of fresh tomatoes were analyzed with standard methods, and those values were correlated to spectral data by partial least squares regression (PLSR). Fresh tomato samples were obtained in 2018 and 2019 crops in commercial production, and four fruit types were evaluated: Roma, round, grape, and cherry tomatoes. The large variation in tomato types and having the fruits from distinct years resulted in a wide range in quality parameters enabling robust PLSR models. Results showed accurate prediction and good correlation (Rpred) for SSC = 0.87, glucose = 0.83, fructose = 0.87, ascorbic acid = 0.81, and citric acid = 0.86. Our results support the assertion that a handheld NIR spectrometer has a high potential to simultaneously determine several quality attributes of different types of tomatoes in a practical and fast way.


2002 ◽  
Vol 10 (3) ◽  
pp. 203-214 ◽  
Author(s):  
N. Gierlinger ◽  
M. Schwanninger ◽  
B. Hinterstoisser ◽  
R. Wimmer

The feasibility of Fourier transform near infrared (FT-NIR) spectroscopy to rapidly determine extractive and phenolic content in heartwood of larch trees ( Larix decidua MILL., L. leptolepis (LAMB.) CARR. and the hybrid L. x eurolepis) was investigated. FT-NIR spectra were collected from wood powder and solid wood using a fibre-optic probe. Partial Least Squares (PLS) regression analyses were carried out describing relationships between the data sets of wet laboratory chemical data and the FT-NIR spectra. Besides cross and test set validation the established models were subjected to a further evaluation step by means of additional wood samples with unknown extractive content. Extractive and phenol contents of these additional samples were predicted and outliers detected through Mahalanobis distance calculations. Models based on the whole spectral range and without data pre-processing performed well in cross-validation and test set validation, but failed in the evaluation test, which is based on spectral outlier detection. But selection of data pre-processing methods and manual as well as automatic restriction of wavenumber ranges considerably improved the model predictability. High coefficients of determination ( R2) and low root mean square errors of cross-validation ( RMSECV) were obtained for hot water extractives ( R2 = 0.96, RMSECV = 0.86%, range = 4.9–20.4%), acetone extractives ( R2 = 0.86, RMSECV = 0.32%, range = 0.8–3.6%) and phenolic substances ( R2 = 0.98, RMSECV = 0.21%, range = 0.7–4.9%) from wood powder. The models derived from wood powder spectra were more precise than those obtained from solid wood strips. Overall, NIR spectroscopy has proven to be an easy to facilitate, reliable, accurate and fast method for non-destructive wood extractive determination.


Sign in / Sign up

Export Citation Format

Share Document