Micropatterning Cells on Permeable Membrane Filters

Author(s):  
Sahar Javaherian ◽  
Ana C. Paz ◽  
Alison P. McGuigan
Author(s):  
Lawrence W. Ortiz ◽  
Bonnie L. Isom

A procedure is described for the quantitative transfer of fibers and particulates collected on membrane filters to electron microscope (EM) grids. Various Millipore MF filters (Millipore AA, HA, GS, and VM; 0.8, 0.45, 0.22 and 0.05 μm mean pore size) have been used with success. Observed particle losses have not been size dependent and have not exceeded 10%. With fibers (glass or asbestos) as the collected media this observed loss is approximately 3%.


2009 ◽  
Vol 129 (11) ◽  
pp. 380-386 ◽  
Author(s):  
Taizo Kobayashi ◽  
Daiki Kato ◽  
Hiroyuki Koga ◽  
Kenichi Morimoto ◽  
Makoto Fukuda ◽  
...  

2003 ◽  
Vol 3 (5-6) ◽  
pp. 67-72
Author(s):  
S. Takizawa ◽  
T. Win

In order to evaluate effects of operational parameters on the removal efficiency of trichloroethylene and 1,1,1-trichloroethene from water, lab-scale experiments were conducted using a novel hollow-fibre gaspermeable membrane system, which has a very thin gas-permeable membrane held between microporous support membranes. The permeation rate of chlorinated hydrocarbons increased at higher temperature and water flow rate. On the other hand, the effects of the operational conditions in the permeate side were complex. When the permeate side was kept at low pressure without sweeping air (pervaporation), the removal efficiency of chlorinated hydrocarbon, as well as water permeation rate, was low probably due to lower level of membrane swelling on the permeate side. But when a very small amount of air was swept on the membrane (air perstripping) under a low pressure, it showed a higher efficiency than in any other conditions. Three factors affecting the permeation rate are: 1) reduction of diffusional boundary layer within the microporous support membrane, 2) air/vapour flow regime and short cutting, and 3) the extent of membrane swelling on the permeate side. A higher air flow, in general, reduces the diffusional boundary layer, but at the same time disrupts the flow regime, causes short cutting, and makes the membrane dryer. Due to these multiple effects on gas permeation, there is an optimum operational condition concerning the vacuum pressure and the air flow rate. Under the optimum operational condition, the residence time within the hollow-fibre membrane to achieve 99% removal of TCE was 5.25 minutes. The log (removal rate) was linearly correlated with the average hydraulic residence time within the membrane, and 1 mg/L of TCE can be reduced to 1 μg/L (99.9% removal).


1993 ◽  
Vol 27 (3-4) ◽  
pp. 1-13 ◽  
Author(s):  
Arie H. Havelaar ◽  
Siem H. Heisterkamp ◽  
Janneke A. Hoekstra ◽  
Kirsten A. Mooijman

The general concept of measurement errors is applied to quantitative bacteriological counts on membrane filters or agar plates. The systematic errors of these methods are related to the growth characteristics of the medium (recovery of target organisms and inhibition of non-target organisms) and to its differential characteristics (sensitivity and specificity). Factors that influence the precision of microbiological counts are the variation between replicates, within samples, between operators and between laboratories. It is also affected by the linearity of the method, the verification rate and, where applicable, the number of colonies subcultured for verification. Repeatability (r) and reproducibility (R) values can be calculated on the logarithmic scale.


1997 ◽  
Vol 35 (11-12) ◽  
pp. 77-80 ◽  
Author(s):  
A. Wiedenmann ◽  
M. Braun ◽  
K. Botzenhart

A simple continuous flow device in which bacteria were immobilised on membrane filters and flushed with tap water with free chlorine residuals of 0.05, 0.1, 0.2 and 0.4mg/L at pH 7.7 and 10°C, has been used for disinfection experiments with faecal streptococci. A 99.99% reduction of Enterococcus faecium was observed between 3.4–5.2min (0.05mg/L), between 2.8–4.1min (0.1mg/L), between 1.7–3.1min (0.2mg/L) and between 0.8–2.1min (0.4mg/L). CT-products covered a range of 0.17 (0.05mg/L, lower limit) up to 0.85mg/L/min (0.4mg/L, upper limit). The test system is suggested as a more reliable alternative to batch experiments when the disinfection potential of low chlorine concentrations acting for several minutes has to be evaluated. The system cannot be used to demonstrate exact reduction kinetics but it allows the calculation of CT values and the evaluation of the disinfection potential of chlorinated water at any point of a distribution system where initial chlorine concentrations may have already remarkably declined.


2019 ◽  
Vol 9 (1) ◽  
pp. 29-36
Author(s):  
Bijaya Ghosh ◽  
Niraj Mishra ◽  
Preeta Bose ◽  
Moumita D. Kirtania

Objective: Rheumatoid arthritis is a dreaded disease, characterized by pain, inflammation and stiffness of joints, leading to severe immobility problems. The disease shows circadian variation and usually gets aggravated in early morning hours. Aceclofenac, a BCS Class II compound is routinely used in the treatment of pain and inflammation associated with rheumatoid arthritis. The objective of this study was to develop an osmotic delivery system of Aceclofenac that after administration at bedtime would deliver the drug in the morning hours. </P><P> Methods: A series of osmotically controlled systems of aceclofenac was developed by using lactose, sodium chloride and hydroxypropyl methylcellulose K100M as osmogens. Cellulose acetate (2% w/v in acetone) with varying concentrations of polyethylene glycol-400 was used as the coating polymer to create semi permeable membrane and dissolution was carried out in 290 mOsm phosphate buffer. Formulation optimization was done from four considerations: cumulative release at the end of 6 hours (lag time), cumulative release at the end of 7 hours (burst time), steady state release rate and completeness of drug release. </P><P> Results: A formulation having swelling polymer hydroxypropyl methylcellulose in the core and lactose and sodium chloride as osmogens, polyethylene glycol-400 (16.39 %) as pore former, with a coating weight of 5% was a close fit to the target release profile and was chosen as the optimum formulation. Conclusion: Aceclofenac tablets containing lactose, HPMC and sodium chloride in the core, given a coating of cellulose acetate and PEG-400 (5% wt gain), generated a release profile for optimum management of rheumatoid arthritic pain.


Sign in / Sign up

Export Citation Format

Share Document