The influence of zinc electrode substrate, electrolyte flow rate and current density on zinc-nickel flow cell performance

2021 ◽  
Vol 373 ◽  
pp. 137890
Author(s):  
David P. Trudgeon ◽  
Adeline Loh ◽  
Habib Ullah ◽  
Xiaohong Li ◽  
Vladimir Yufit ◽  
...  
2014 ◽  
Vol 716-717 ◽  
pp. 94-97
Author(s):  
Yan Xue Li ◽  
Ming Chui Dong ◽  
Peng Cheng Zhao ◽  
Ying Duo Han

In operating of a flow battery, a certain flow rate should be maintained in order to guarantee its performance. But the pump consumed power may cause significant losses for the overall battery system. In this paper, a fresh electrical model is proposed for the novel single flow zinc-nickel battery. The model consists of both battery stack part and pump power part, which consequently not only predicts accurately the battery electrical output, but also estimates the pump consumed power at different electrolyte flow rate. Based on the validated model, the influence of pump power on flow battery’s system efficiency can be evaluated at different operating modes. At last, possible means to further improve the system efficiency of battery is discussed.


Energies ◽  
2019 ◽  
Vol 12 (4) ◽  
pp. 582 ◽  
Author(s):  
Shouguang Yao ◽  
Xiaofei Sun ◽  
Min Xiao ◽  
Jie Cheng ◽  
Yaju Shen

Based on the zinc–nickel single-flow battery, a generalized electrical simulation model considering the effects of flow rate, self-discharge, and pump power loss is proposed. The results compared with the experiment show that the simulation results considering the effect of self-discharge are closer to the experimental values, and the error range of voltage estimation during charging and discharging is between 0% and 3.85%. In addition, under the rated electrolyte flow rate and different charge–discharge currents, the estimation of Coulomb efficiency by the simulation model is in good agreement with the experimental values. Electrolyte flow rate is one of the parameters that have a great influence on system performance. Designing a suitable flow controller is an effective means to improve system performance. In this paper, the genetic algorithm and the theoretical minimum flow multiplied by different flow factors are used to optimize the variable electrolyte flow rate under dynamic SOC (state of charge). The comparative analysis results show that the flow factor optimization method is a simple means under constant charge–discharge power, while genetic algorithm has better performance in optimizing flow rate under varying (dis-)charge power and state of charge condition in practical engineering.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1546
Author(s):  
Árpád Imre-Lucaci ◽  
Melinda Fogarasi ◽  
Florica Imre-Lucaci ◽  
Szabolcs Fogarasi

This paper presents a novel approach for the recovery of lead from waste cathode-ray tube (CRT) glass by applying a combined chemical-electrochemical process which allows the simultaneous recovery of Pb from waste CRT glass and electrochemical regeneration of the leaching agent. The optimal operating conditions were identified based on the influence of leaching agent concentration, recirculation flow rate and current density on the main technical performance indicators. The experimental results demonstrate that the process is the most efficient at 0.6 M acetic acid concentration, flow rate of 45 mL/min and current density of 4 mA/cm2. The mass balance data corresponding to the recycling of 10 kg/h waste CRT glass in the identified optimal operating conditions was used for the environmental assessment of the process. The General Effect Indices (GEIs), obtained through the Biwer Heinzle method for the input and output streams of the process, indicate that the developed recovery process not only achieve a complete recovery of lead but it is eco-friendly as well.


2010 ◽  
Vol 177 ◽  
pp. 407-410
Author(s):  
Xi Bao Li ◽  
Jian Wang ◽  
Xiao Hua Yu ◽  
Hong Xing Gu ◽  
Gang Qin Shao

NiO-YSZ (NiO-yttria stabilized zirconia, 3:2, wt.%) and samaria doped ceria (SDC) tapes were prepared by aqueous tape casting. NiO-YSZ anode-supported SDC film electrolyte half-cell was fabricated by laminating and co-sintering at 1400°C for 2 h. The single cell was prepared after LSCF-SDC (lanthanum strontium cobalt ferrite-SDC, 1:1, wt.%) cathode was coated on the electrolyte surface and sintered at 1300 °C for 2 h. The discharge performance of the single cell was tested from 500 °C to 800 °C at different H2 flow rate. Results showed that the relationship between current (I) of and H2 flow rate (ν) was I = 8 × 106 ν. Before reaching the threshold value of H2 flow rate, the current density of single cell increased with the increasing of H2 flow rate. However, the current density did not change with increasing of H2 flow rate over the threshold value. The open circuit voltage (OCV) of single cell at 500°C, 600°C, 700°C, 800°C was 0.978, 0.921, 0.861, 0.803 V, respectively. The maximum power density reached 93.03 mW/cm2 at 800°C. The resistance of interface layer between Ni-YSZ anode and SDC electrolyte was the key impact on the power density.


Author(s):  
Yuichiro Tabuchi ◽  
Takeshi Shiomi ◽  
Osamu Aoki ◽  
Norio Kubo ◽  
Kazuhiko Shinohara

Heat and water transport in polymer electrolyte membrane fuel cell (PEMFC) has considerable impacts on cell performance under high current density which is desired in PEMFC for automobiles. In this study, the impact of rib/channel, heat and water transport on cell performance under high current density was investigated by experimental evaluation of liquid water distribution and numerical validation. Liquid water distribution between rib and channel is evaluated by Neutron Radiography. In order to neglect the effect of liquid water in channel and the distribution of oxygen and hydrogen concentration distribution along with channel length, the differential cell was used in this study. Experimental results show that liquid water under channel was dramatically changed with Rib/Channel width. From numerical study, it is found that the change of liquid water distribution was strongly affected by temperature distribution between rib and channel. In addition, not only heat transport but also water transport through membrane also significantly affected cell performance under high current density operation. From numerical validation, it is concluded that this effect on cell performance under high current density could be due to the enhancement of back-diffusion of water through membrane.


2021 ◽  
pp. 55-60
Author(s):  

The features of the hydrodynamics of the electrolyte in the interelectrode gap during electrochemical processing of a profile axisymmetric workpiece are considered. The distribution of average flow rates and flow lines is calculated for a specified electrolyte supply. The nature and rate of the electrolyte flow are established. The unevenness of the current density is determined taking into account the change in the electrical conductivity of the electrolyte from heating and gas filling of the interelectrode gap, as well as the quality of the treated surface. Keywords: electrochemical treatment, roughness, electrolyte, electrical conductivity, gas filling. [email protected]


Sign in / Sign up

Export Citation Format

Share Document