Study on flexural behavior of spliced shallow composite beams with different shear connectors

2022 ◽  
Vol 253 ◽  
pp. 113816
Author(s):  
Shan Gao ◽  
Qi Bai ◽  
Lanhui Guo ◽  
Shao-Bo Kang ◽  
Anna Derlatka ◽  
...  
2018 ◽  
Vol 7 (4.20) ◽  
pp. 174
Author(s):  
Alaa M. Al-Khekany ◽  
Labeeb S. Al-Yassri ◽  
Munaf A. Al-Ramahee ◽  
Saeed Abdul-Abbas

This research presents an experimental program to study the effect of using angle shear connectors instead of the headed stud on the flexural behavior of composite beams under negative bending moment (NBM). Both the angle and headed stud shear connectors used in this study have the same cross-sectional area. Five composite beams were casted and tested using three-point load configuration to ensure the NBM effect. Different parameters were included in this study such as the type of shear connector, bond interaction (partial and complete bond interaction) and arrangement of angle shear connectors. Two proposals method were suggested for angle setting in this study to investigate the structural behavior of the composite section. It has been found that, in the case of single angle shear connectors, the ultimate strength decreased by 4.12% compared with samples with the headed stud shear connectors. The direction of the angle setting has been shown to affect the flexural behavior of the composite section. 


2019 ◽  
Vol 26 (1) ◽  
pp. 51-61
Author(s):  
Amer M. Ibrahim ◽  
Wissam D. Salman ◽  
Fahad M. Bahlol

Steel hollow sections used widely in many engineering applications as structural members. This paper aims to present a study about the flexural behavior of composite beams with steel tubes sections through a series of bending tests in order to study and examine the influence of using different shapes of steel tube section (square, rectangular and hexagonal) with the same shear connector type (headed stud or angle or perfobond) on the flexural behavior and the bending properties of these sections. As well as study the effect of using different shear connectors types (headed stud, angle and perfobond) in the same steel tube section (hexagonal or square or rectangular) on the flexural behavior of composite beams. The experimental program divided into two groups, the first consists of testing nine specimens which focusing on testing three types of steel section when using shear stud at first, angle at second, perfobond at third as shear connector type. Second group consists of testing nine specimens of composite beams too, this group focusing on testing every steel section (hexagonal or square or rectangular) alone when using three types of shear connectors with it. All specimens are with length, width and height equal to 2000, 400 and 130 mm respectively. The tested steel tubes have thickness of 2 mm, yield stress of 322 MPa and the ultimate strength of 390 MPa. The results showed that these shapes of hollow steel sections (hexagonal, square and rectangular) sustain the quality of services for the buildings, and these tested specimens are applicable by giving a distinctive strength and stiffness starting from 114 kN as ultimate load reaching to 170 kN. The experimental results proved that the perfobond and angle connector types are clearly effective shear connectors, shear connector of perfobond type increased the ultimate load of composite beams by (6.25-9.74) % compared with stud shear connector.


2020 ◽  
Vol 92 (6) ◽  
pp. 59-65
Author(s):  
G.P. TONKIH ◽  
◽  
D.A. CHESNOKOV ◽  
◽  

Most of Russian research about composite structure fire resistance are dedicated to the composite slab behavior. The composite beams fire resistance had been never investigated in enough volume: the temperature evaluation within the scope of the actual Russian design codes leads to the significant reduction in the shear connection strength. Meanwhile, there no correlation between the strength decreasing and type of the shear connection. The article provides an overview of the relevant researches and offers some approaches which could take into account bearing capacity reduction of the shear connectors within composite structures design.


2021 ◽  
pp. 152808372110003
Author(s):  
M Atta ◽  
A Abu-Sinna ◽  
S Mousa ◽  
HEM Sallam ◽  
AA Abd-Elhady

The bending test is one of the most important tests that demonstrates the advantages of functional gradient (FGM) materials, thanks to the stress gradient across the specimen depth. In this research, the flexural response of functionally graded polymeric composite material (FGM) is investigated both experimentally and numerically. Fabricated by a hand lay-up manufacturing technique, the unidirectional glass fiber reinforced epoxy composite composed of ten layers is used in the present investigation. A 3-D finite element simulation is used to predict the flexural strength based on Hashin’s failure criterion. To produce ten layers of FGM beams with different patterns, the fiber volume fraction ( Vf%) ranges from 10% to 50%. A comparison between FGM beams and conventional composite beams having the same average Vf% is made. The experimental results show that the failure of the FGM beams under three points bending loading (3PB) test is initiated from the tensioned layers, and spread to the upper layer. The spreading is followed by delamination accompanied by shear failures. Finally, the FGM beams fail due to crushing in the compression zone. Furthermore, the delamination failure between the layers has a major effect on the rapidity of the final failure of the FGM beams. The present numerical results show that the gradient pattern of FGM beams is a critical parameter for improving their flexural behavior. Otherwise, Vf% of the outer layers of the FGM beams, i.e. Vf% = 30, 40, or 50%, is responsible for improving their flexural strength.


2020 ◽  
pp. 136943322098166
Author(s):  
Weiwei Lin

In this study, straight composite steel-concrete beams were tested to investigate their mechanical performance under combined negative bending and torsional moments. Two specimens were used in this study, and different ratios between the applied negative bending and torsional moments were induced. Load and deflection relationships, strain development on the steel main girder and shear connectors (stud), and the slip development on the steel-concrete interface were recorded in the test and reported in this paper. The results indicate that increase of torsional moment will result in the significant decrease of the load-carrying capacities (e.g. yield load and ultimate load) of the specimens. It was also found that the normal strains of stud shear connectors in such beams are very large and non-negligible compared to their shear strains. In addition, the maximum interface slip was found occurring at around the 1/4 span, and the support conditions and serious crack of the concrete were considered to be the main causes. The research results obtained in this study can provide references for the design and analysis of steel-concrete composite beams subjected to the combined negative bending and torsional moments.


2018 ◽  
Author(s):  
◽  
Ayman Elzohairy

[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The steel-concrete composite beam represents a structural system widely employed in both buildings and girder bridges. The coupling between steel beams and concrete flanges assures both economic and structural benefits because of quick construction of steel structures and large increase in stiffness due to the presence of concrete. Strengthening with external post-tensioning (PT) force is particularly effective and economical for long-span steel-concrete composite beams and has been employed with great success to increase the bending and shear resistance and correct excessive deflections. Applying external PT force to the steel-concrete composite beam is considered an active strengthening technique that can create permanent internal straining action in the beam which is opposite to the existing straining action due to the applied service loads. The most benefits of using this system of strengthening are an elastic performance to higher loads, higher ultimate capacity, and reduction in deformation under the applied loads. Under service loads, bridge superstructures are subjected to cyclic loads which may cause a premature failure due to fatigue. Therefore, fatigue testing is critical to evaluate existing design methods of steel-concrete composite beams. ... This research presents static and fatigue tests on four steel-concrete composite specimens to evaluate the effect of externally post-tensioned tendons on the ultimate strength and fatigue behavior of composite beams. Fatigue tests are conducted to a million cycles under a four-point bending test. In addition, final static tests are performed on fatigued specimens to evaluate the residual strength of the strengthened specimen. A numerical model is described to predict the fatigue response of the composite beam by considering the fatigue damage in the concrete flange. The accuracy of the developed numerical model is validated using the existing test data. The static test results indicate that the external post-tensioning force improves the flexural behavior of the strengthened specimen by increasing the beam capacity and reducing the tensile stress in the bottom flange of the steel beam. The fatigue results demonstrate that the external post-tensioning significantly decreases the strains in the shear connectors, concrete flange, and steel beam. The tendons demonstrated an excellent fatigue performance, with no indication of distress at the anchors.


2019 ◽  
Vol 208 ◽  
pp. 454-465 ◽  
Author(s):  
Wenjie Ge ◽  
Ashraf F. Ashour ◽  
Dafu Cao ◽  
Weigang Lu ◽  
Peiqi Gao ◽  
...  

Author(s):  
Mohammed Abdulhussein Al-Shuwaili ◽  
Alessandro Palmeri ◽  
Maria Teresa Lombardo

Push-out tests (POTs) have been widely exploited as an alternative to the more expensive full-scale bending tests to characterize the behaviour of shear connections in steel-concrete composite beams. In these tests, two concrete slabs are typically attached to a steel section with the connectors under investigation, which are then subjected to direct shear. The results allow quantifying the relationship between applied load and displacements at the steel-concrete interface. Since this relationship is highly influenced by the boundary conditions of POT samples, different experimental setups have been used, where the slabs are either restricted or free to slide horizontally, as researchers have tried to reduce any discrepancy between POT and full-scale composite beam testing. Based on a critical review of various POT configurations presented in the dedicated literature, this paper presents an efficient one-sided POT (OSPOT) method. While OSPOT and POT specimens are similar, in the proposed OPSPOT setup only one of the two slabs is directly loaded in each test, and the slab is free to move vertically. Thus, two results can be obtained from one specimen, i.e. one from each slab. A series of POTs and OSPOTs have been conducted to investigate the behaviour and the shear resistance of headed stud connectors through the two methods of testing. The results of this study than were compared with those of different POTs setups conducted by other researchers. The new OSPOT results show in general an excellent agreement with the analytical predictions offered by both British and European standards, as well as the estimated shear resistance proposed other researchers in the literature. These findings suggest that the proposed one-sided setup could be used as an efficient and economical option for conducting the POT, as it has the potential not only to double the number of results, but also to simplify the fabrication of the samples, which is important in any large experimental campaign, and to allow testing with limited capacity of the actuator. 