Facile fabrication of a superhydrophobic fabric with mechanical stability and easy-repairability

2012 ◽  
Vol 380 (1) ◽  
pp. 182-186 ◽  
Author(s):  
Xiaotao Zhu ◽  
Zhaozhu Zhang ◽  
Jin Yang ◽  
Xianghui Xu ◽  
Xuehu Men ◽  
...  
Author(s):  
Weiheng Xu ◽  
Dharneedar Ravichandran ◽  
Sayli Jambhulkar ◽  
Yuxiang Zhu ◽  
Kenan Song

Abstract Carbon nanoparticles-based polymer composites have wide applications across different fields for their unique functional properties, durability, and chemical stability. When combining nanoparticle morphologies with micro- or macro-scale morphologies, the hierarchal structure often would greatly enhance the composites’ functionalities. Here in this work, a thermoplastic polyurethane (TPU) and graphene nanoplatelets (GnPs) based multilayered fiber is fabricated through the combination of dry-jet-wet spinning, based on an in-house designed spinneret which accommodates three layers spinning solution, and hot isostatic pressing (HIP), at 220 °C. The multilayered spinneret enables the spinnability of a high GnPs loaded spinning dope, highly elastic, with great mechanical strength, elongation, and flexibility. The HIP process resulted in superior electrical properties as well as a newly emerged fourth hollow layer. Together, such a scalable fabrication method promotes a piezoresistive sensor that is sensitive to uniaxial strain and radial air pressure. The hollow fiber is characterized based on surface morphologies, layer formation, percolation threshold, piezoresistive gauge factor, mechanical stability and reversibility, and air-pressure sensitivity and reversibility. Such facile fabrication methods and unique structures have combined the mechanically robust outer shell with a highly conductive middle sensing layer for a new sensor with great potentials in wearable, robotics, biomedical, and other areas.


Author(s):  
W.K. Lo ◽  
J.C.H. Spence

An improved design for a combination Scanning Tunnelling Microscope/TEM specimen holder is presented. It is based on earlier versions which have been used to test the usefulness of such a device. As with the earlier versions, this holder is meant to replace the standard double-tilt specimen holder of an unmodified Philips 400T TEM. It allows the sample to be imaged simultaneously by both the STM and the TEM when the TEM is operated in the reflection mode (see figure 1).The resolution of a STM is determined by its tip radii as well as its stability. This places strict limitations on the mechanical stability of the tip with respect to the sample. In this STM the piezoelectric tube scanner is rigidly mounted inside the endcap of the STM holder. The tip coarse approach to the sample (z-direction) is provided by an Inchworm which is located outside the TEM vacuum.


Author(s):  
Oliver C. Wells ◽  
Mark E. Welland

Scanning tunneling microscopes (STM) exist in two versions. In both of these, a pointed metal tip is scanned in close proximity to the specimen surface by means of three piezos. The distance of the tip from the sample is controlled by a feedback system to give a constant tunneling current between the tip and the sample. In the low-end STM, the system has a mechanical stability and a noise level to give a vertical resolution of between 0.1 nm and 1.0 nm. The atomic resolution STM can show individual atoms on the surface of the specimen.A low-end STM has been put into the specimen chamber of a scanning electron microscope (SEM). The first objective was to investigate technological problems such as surface profiling. The second objective was for exploratory studies. This second objective has already been achieved by showing that the STM can be used to study trapping sites in SiO2.


Author(s):  
Debby A. Jennings ◽  
Michael J. Morykwas ◽  
Louis C. Argenta

Grafts of cultured allogenic or autogenic keratlnocytes have proven to be an effective treatment of chronic wounds and burns. This study utilized a collagen substrate for keratinocyte and fibroblast attachment. The substrate provided mechanical stability and augmented graft manipulation onto the wound bed. Graft integrity was confirmed by light and transmission electron microscopy.Bovine Type I dermal collagen sheets (100 μm thick) were crosslinked with 254 nm UV light (13.5 Joules/cm2) to improve mechanical properties and reduce degradation. A single cell suspension of third passage neonatal foreskin fibroblasts were plated onto the collagen. Five days later, a single cell suspension of first passage neonatal foreskin keratinocytes were plated on the opposite side of the collagen. The grafts were cultured for one month.The grafts were fixed in phosphate buffered 4% formaldehyde/1% glutaraldehyde for 24 hours. Graft pieces were then washed in 0.13 M phosphate buffer, post-fixed in 1% osmium tetroxide, dehydrated, and embedded in Polybed 812.


Author(s):  
C. C. Ahn ◽  
S. Karnes ◽  
M. Lvovsky ◽  
C. M. Garland ◽  
H. A. Atwater ◽  
...  

The bane of CCD imaging systems for transmission electron microscopy at intermediate and high voltages has been their relatively poor modulation transfer function (MTF), or line pair resolution. The problem originates primarily with the phosphor screen. On the one hand, screens should be thick so that as many incident electrons as possible are converted to photons, yielding a high detective quantum efficiency(DQE). The MTF diminishes as a function of scintillator thickness however, and to some extent as a function of fluorescence within the scintillator substrates. Fan has noted that the use of a thin layer of phosphor beneath a self supporting 2μ, thick Al substrate might provide the most appropriate compromise for high DQE and MTF in transmission electron microcscopes which operate at higher voltages. Monte Carlo simulations of high energy electron trajectories reveal that only little beam broadening occurs within this thickness of Al film. Consequently, the MTF is limited predominantly by broadening within the thin phosphor underlayer. There are difficulties however, in the practical implementation of this design, associated mostly with the mechanical stability of the Al support film.


Author(s):  
John G. Sheehan

The goal is to examine with high resolution cryo-SEM aqueous particulate suspensions used in coatings for printable paper. A metal-coating chamber for cryo-preparation of such suspensions was described previously. Here, a new conduction-cooling system for the stage and cold-trap in an SEM specimen chamber is described. Its advantages and disadvantages are compared to a convection-cooling system made by Hexland (model CT1000A) and its mechanical stability is demonstrated by examining a sample of styrene-butadiene latex.In recent high resolution cryo-SEM, some stages are cooled by conduction, others by convection. In the latter, heat is convected from the specimen stage by cold nitrogen gas from a liquid-nitrogen cooled evaporative heat exchanger. The advantage is the fast cooling: the Hexland CT1000A cools the stage from ambient temperature to 88 K in about 20 min. However it consumes huge amounts of liquid-nitrogen and nitrogen gas: about 1 ℓ/h of liquid-nitrogen and 400 gm/h of nitrogen gas. Its liquid-nitrogen vessel must be re-filled at least every 40 min.


2019 ◽  
Vol 14 (4) ◽  
pp. 349-352
Author(s):  
Xiaohai Bu ◽  
Dongxian Li ◽  
Zewu Zhang ◽  
Chaofeng Hong ◽  
Li Zhang ◽  
...  
Keyword(s):  

2000 ◽  
Vol 628 ◽  
Author(s):  
Giovanni Carturan ◽  
Renzo Dal Monte ◽  
Maurizio Muraca

ABSTRACTSi-alkoxides in gas phase are reactive towards the surface of animal cells, depositing a homogeneous layer of porous silica. This encapsulation method preserves cell viability and does not alter the hindrance of the biological load.In the prospective use for the design of a hybrid bioartificial liver, hepatocytes in a collagen matrix can be entrapped by the siliceous deposit which provides definite mechanical stability to the collagen matrix and molecular cutoff vs. high molecular weight proteins, including immunoglobulins. The functionality of the encapsulated cell load is maintained for the expressions of typical liver and pancreas metabolic activities.


Sign in / Sign up

Export Citation Format

Share Document