scholarly journals Remediation of clayey soil contaminated with nickel nitrate using enhanced Electro-Kinetics process and study the geotechnical properties of the remediated soil samples

2021 ◽  
Vol 42 ◽  
pp. 2516-2520
Author(s):  
Ali A. Kamal ◽  
Abdulkhaleq K. Mahmood ◽  
Shahad Duja
2019 ◽  
Vol 9 (1) ◽  
pp. 64-73
Author(s):  
Ferzand K. Medhat ◽  
Mehmet Carpuzcu ◽  
Ali Firat Cabalar ◽  
Ahmed Al-Obaidi

This study presents the effect of Kawergosk refinery waste oil on the geotechnical properties of Erbil clayey soils. A comparison of laboratory test results on uncontaminated clayey soils has been presented and examined. Refinery waste oil of Kawergosk (20 km west of Erbil city) was chosen as the contaminant. A disturbed soil samples were collected from the site which are remolded in the laboratory before each test to represent the field dry density (1.4 gm/cm3, 5.6% water content). Laboratory investigations were carried out on soil samples with 5%, 10%, 15%, and 20% of the waste oil, the results showed a considerable effect on the chemical soil characteristics, while a slight increase of the values of Atterberg limits was observed. A considerable effect on the values of one-dimensional consolidation test parameters has also been observed; the same observation has been seen for the values of direct shear test parameters. A reduction on the values of conductivity coefficient, K has been noticed with increase of contaminated percentage.


2017 ◽  
Vol 63 (1) ◽  
pp. 47-62 ◽  
Author(s):  
M. O. Karkush ◽  
T. A. A. Al-Taher

Abstract The impacts of industrial wastewater contamination on the geotechnical properties of clayey soil have been studied in the research presented in this paper. The contaminant in question is industrial wastewater released from Thi-Qar oil refinery as a by-product of production, and the soil samples obtained from Thi-Qar oil refinery plant in Al-Nassyriah (a city located in the south of Iraq). The geotechnical properties of contaminated soil samples were compared with those of intact soil to measure the effects of such a contaminant. The soil samples were obtained from three locations in the study area; representing the highly contaminated area, the slightly contaminated area, and the intact area used as a reference for comparison of test results. The results of the tests showed that the contaminant causes an increase of natural moisture content, field unit weight, Atterberg’s limits, and maximum dry unit weight, as well as an increase of the compression index and the coefficient of vertical consolidation. Also, the contaminant causes a decrease in specific gravity, the optimum moisture content initial void ratio, the swelling index, the coefficient of permeability, and cohesion between soil particles.


2021 ◽  
Vol 1036 (1) ◽  
pp. 012035
Author(s):  
A C Ekeleme ◽  
O H Ibearugbulem ◽  
E I Ugwu ◽  
C E Njoku ◽  
E C Amanamba ◽  
...  

2021 ◽  
Vol 11 (14) ◽  
pp. 6451
Author(s):  
Christian E. Hernández-Mendoza ◽  
Pamela García Ramírez ◽  
Omar Chávez Alegría

Soil contamination by different hydrocarbons has rapidly expanded worldwide, surpassing the self-purification capacity of soils and increasing the number of contaminated sites. Although much effort has been devoted to study the effects of diesel contamination on the geotechnical properties of soil, there is still limited available information about it. Moreover, there is no available information about the maximum diesel retention that soil can have and its effect on the geotechnical behavior of the soil. Thus, in this paper, we determined the maximum diesel retention by an unsaturated clayey soil and evaluated the impact of diesel contamination on its geotechnical properties. The results showed that the soil could only retain 12.6% of the added diesel and the excess was expulsed. At such a diesel concentration, the saturation rate of the soil was lower than 80%. Diesel contamination increased the plasticity and the internal friction angle of the soil, while its cohesion was considerably decreased. It should be noted that the matric suction of contaminated soil was lower than the one obtained for natural soil. However, its osmotic suction was considerably higher. This indicates that osmotic suction must be considered to evaluate the shear strength of contaminated soils.


Author(s):  
Mahdi O. Karkush ◽  
Shahad D. Ali

In this research, the effectsof coppersulfate contamination on the chemical, physical and mechanical properties of cohesive soil have been studied and compared with the properties of intact soil. Soil sampleswere obtained from Al-Ahdab oil field in Wasit governorate, located in the east of Iraq. In the laboratory, the soil specimens were contaminated artificiallywith three quantities of copper sulfate) CuSO4.5H2O) (100, 200 and 400) gm. The contaminantwas dissolved in 10 liters of distilled water and then added to the intact soil. The intact soil samplekept soaked with the contaminantfor 30 days. Several tests were conducted onthe soil samples (intact and contaminated) to measure the effects of copper sulfate on the geotechnical properties of clayey soil. The results of tests showed significant effectsfor copper on the studied soil properties. The copper sulfate causesdecreasing the percentage of fine particles in the soil, Atterberg s limits, permeability and optimum water content. Inaddition, the copper sulfate causes increasing thespecific gravity andmaximum dry density of soil. The shear strength parameters of soil are measured by using direct shear test, unconfined compression test and unconsolidated undrained triaxial test are decreased with increasing the concentration of copper sulfate in soil. Also, its noted increasing the initial void ratio, the compression index and recompression index with increasing concentration of contaminant in soil.


2020 ◽  
Vol 16 (2) ◽  
pp. 289-298
Author(s):  
Musab Sabah Abed

AbstractWith the intention of providing a balance between the disposal of wastes generated from incineration processes and mitigate the emissions from industrial activities, the reuse of incineration waste as alternatives to conventional binders would offer a sustainable solution to reduce their environmental impact. This study aims to experimentally investigate the effect of firewood, ash (FWA) and ordinary Portland cement on some of the geotechnical properties of low plastic clayey soil (CL). The experimental program was introduced by partial replacement of ordinary Portland cement with firewood ash (FWA) up to 10 % with an increment of 2 %. A series of unconfined compressive test (UCT) and Atterberg limits test were performed. The results indicate that plasticity characteristics are affected by the addition of both cement and (FWA). Also, the results showed that the unconfined compressive strength increases for all replacement levels in comparison with the plain clay sample. The term deformability index (DI) also discussed with respect to different replacement level. The 70.61 % pozzolanic activity index indicates that (FWA) is a good pozzolan in accordance with ASTM C 618 specification. Finally, three modes of failure were detected which varying in accordance with the proportion of replacement.


Sign in / Sign up

Export Citation Format

Share Document