Nanomaterials for fluorescent detection of curcumin

Author(s):  
Yongming Guo ◽  
Chao Yang ◽  
Yijia Zhang ◽  
Tao Tao
Micromachines ◽  
2020 ◽  
Vol 11 (2) ◽  
pp. 177 ◽  
Author(s):  
Zengming Zhang ◽  
Shuhao Zhao ◽  
Fei Hu ◽  
Guangpu Yang ◽  
Juan Li ◽  
...  

The sensitive quantification of low-abundance nucleic acids holds importance for a range of clinical applications and biological studies. In this study, we describe a facile microfluidic chip for absolute DNA quantifications based on the digital loop-mediated isothermal amplification (digital LAMP) method. This microfluidic chip integrates a cross-flow channel for droplet generation with a micro-cavity for droplet tiling. DNA templates in the LAMP reagent were divided into ~20,000 water-in-oil droplets at the cross-flow channel. The droplets were then tiled in the micro-cavity for isothermal amplification and fluorescent detection. Different from the existing polydimethylsiloxane (PDMS) microfluidic chips, this study incorporates gold nanoparticles (AuNPs) into PDMS substrate through silica coating and dodecanol modification. The digital LAMP chip prepared by AuNPs-PDMS combines the benefits of the microstructure manufacturing performance of PDMS with the light-to-heat conversion advantages of AuNPs. Upon illumination with a near infrared (NIR) LED, the droplets were stably and efficiently heated by the AuNPs in PDMS. We further introduce an integrated device with a NIR heating unit and a fluorescent detection unit. The system could detect HBV (hepatitis B virus)-DNA at a concentration of 1 × 101 to 1 × 104 copies/μL. The LED-driven digital LAMP chip and the integrated device; therefore, demonstrate high accuracy and excellent performance for the absolute quantification of low-abundance nucleic acids, showing the advantages of integration, miniaturization, cost, and power consumption.


2021 ◽  
Vol 9 (7) ◽  
pp. e002197
Author(s):  
Janis M Taube ◽  
Kristin Roman ◽  
Elizabeth L Engle ◽  
Chichung Wang ◽  
Carmen Ballesteros-Merino ◽  
...  

BackgroundEmerging data suggest predictive biomarkers based on the spatial arrangement of cells or coexpression patterns in tissue sections will play an important role in precision immuno-oncology. Multiplexed immunofluorescence (mIF) is ideally suited to such assessments. Standardization and validation of an end-to-end workflow that supports multisite trials and clinical laboratory processes are vital. Six institutions collaborated to: (1) optimize an automated six-plex assay focused on the PD-1/PD-L1 axis, (2) assess intersite and intrasite reproducibility of staining using a locked down image analysis algorithm to measure tumor cell and immune cell (IC) subset densities, %PD-L1 expression on tumor cells (TCs) and ICs, and PD-1/PD-L1 proximity assessments.MethodsA six-plex mIF panel (PD-L1, PD-1, CD8, CD68, FOXP3, and CK) was rigorously optimized as determined by quantitative equivalence to immunohistochemistry (IHC) chromogenic assays. Serial sections from tonsil and breast carcinoma and non-small cell lung cancer (NSCLC) tissue microarrays (TMAs), TSA-Opal fluorescent detection reagents, and antibodies were distributed to the six sites equipped with a Leica Bond Rx autostainer and a Vectra Polaris multispectral imaging platform. Tissue sections were stained and imaged at each site and delivered to a single site for analysis. Intersite and intrasite reproducibility were assessed by linear fits to plots of cell densities, including %PDL1 expression by TCs and ICs in the breast and NSCLC TMAs.ResultsComparison of the percent positive cells for each marker between mIF and IHC revealed that enhanced amplification in the mIF assay was required to detect low-level expression of PD-1, PD-L1, FoxP3 and CD68. Following optimization, an average equivalence of 90% was achieved between mIF and IHC across all six assay markers. Intersite and intrasite cell density assessments showed an average concordance of R2=0.75 (slope=0.92) and R2=0.88 (slope=0.93) for breast carcinoma, respectively, and an average concordance of R2=0.72 (slope=0.86) and R2=0.81 (slope=0.68) for NSCLC. Intersite concordance for %PD-L1+ICs had an average R2 value of 0.88 and slope of 0.92. Assessments of PD-1/PD-L1 proximity also showed strong concordance (R2=0.82; slope=0.75).ConclusionsAssay optimization yielded highly sensitive, reproducible mIF characterization of the PD-1/PD-L1 axis across multiple sites. High concordance was observed across sites for measures of density of specific IC subsets, measures of coexpression and proximity with single-cell resolution.


The Analyst ◽  
2021 ◽  
Vol 146 (20) ◽  
pp. 6297-6305
Author(s):  
Qinglan Miao ◽  
Ji Qi ◽  
Yuanyuan Li ◽  
Xinxia Fan ◽  
Dongmei Deng ◽  
...  

A novel paper-based chip that anchored zinc-doped carbon dots was constructed for sensitive and stable fluorescent detection of Cu2+. Zn doping increased the active sites for simplifying the modification of carbon dots.


Nanomaterials ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1207
Author(s):  
Hong Jae Cheon ◽  
Quynh Huong Nguyen ◽  
Moon Il Kim

Inspired by the active site structure of natural horseradish peroxidase having iron as a pivotal element with coordinated histidine residues, we have developed histidine coated magnetic nanoparticles (His@MNPs) with relatively uniform and small sizes (less than 10 nm) through one-pot heat treatment. In comparison to pristine MNPs and other amino acid coated MNPs, His@MNPs exhibited a considerably enhanced peroxidase-imitating activity, approaching 10-fold higher in catalytic reactions. With the high activity, His@MNPs then were exploited to detect the important neurotransmitter acetylcholine. By coupling choline oxidase and acetylcholine esterase with His@MNPs as peroxidase mimics, target choline and acetylcholine were successfully detected via fluorescent mode with high specificity and sensitivity with the limits of detection down to 200 and 100 nM, respectively. The diagnostic capability of the method is demonstrated by analyzing acetylcholine in human blood serum. This study thus demonstrates the potential of utilizing His@MNPs as peroxidase-mimicking nanozymes for detecting important biological and clinical targets with high sensitivity and reliability.


2021 ◽  
pp. 129939
Author(s):  
Tai Ye ◽  
Jiaqi Lu ◽  
Min Yuan ◽  
Hui Cao ◽  
Fengqin Yin ◽  
...  

1967 ◽  
Vol 50 (5) ◽  
pp. 1088-1098
Author(s):  
Mohamed Tawfik H Ragab

Abstract A rapid, simple, convenient, and widely applicable method for the direct fluorescent detection of organothiophosphorus pesticides and some postulated breakdown products of these compounds is presented. The coinpounds were spotted on thin layer chromatographic sheets, developed in ethyl acetate :nhexane, and made visible by exposure to bromine vapor followed by spraying with ferric chloride and 2-(o-hydroxy phenyl) benzoxazole. Of the 47 compounds tested, 32 compounds produced fluorescent blue spots vinder longwave ultraviolet light; these consisted of 25 organothiophosphorus pesticides, 5 sulfur-containing breakdown products, and phosphoric and hypophosphorous acids. A superimposed Congo red spray destroyed the fluorescence and resulted in dark blue spots against a red backgrovind. The sensitivity of this method is in the range of 0.2 to 5.0 μg, depending on the specific compound.


Sign in / Sign up

Export Citation Format

Share Document