Rocket Experiment by Electronic Camera for Studying the Metallic Discontinuities in the Ultraviolet Spectrum of ‘A’ Stars

1971 ◽  
Vol 41 ◽  
pp. 361-362
Author(s):  
M. Combes

1.Ultraviolet spectra (1400–1800 Å) of Ap, Am and normal A stars are needed by F. Praderie, R. Bonnet and R. Cayrel.The spectral resolution has to be nearly 1 Å. Accurate relative photometry (5%) and absolute calibration (30–50%) are required.A rocket experiment, proposed to ESRO by M. Combes and P. Felenbok is planned for launch in 1972.2.As neutral silicon and magnesium are very efficient ultra-violet absorbents, A stars ultraviolet fluxes are very faint (Praderie, 1968).Then a very luminous optical set-up and a high efficiency receiver have to be used. A 30 cm in diameter concave objective grating is associated with a Lallemand electronic camera. The grating (2000 //mm; //l) is holographically made (Labeyrie, 1969). The electronic camera is electrostatically focussed. A semi-transparent solar-blind CsL photocathode is used (Carruthers, 1966).3.A little mirror, placed against the grating and forming a direct view of the sky, permits to establish an absolute wavelength scale.During the fly, before and after stellar observations, a little concave mirror mounted into the opening side-door is used to form on the photocathode a spectrum of a Deuterium calibrated lamp. Two photomultipliers, one on each side of the electronic camera, control the lamp stability.The complete mounting is calibrated in the laboratory using a thermopile as reference, before the launch and after the recovery of the waterproof payload.4.The chosen stars are the brightest Ap and Am stars: α Dra (Ap; mv = 3.64; equivalent type A 0) and α2 Lib (Am; mv = 2.75; equivalent type A3-A7).It seems to be possible to obtain spectra (1400-1800 Å) of the Ap star with a spectral resolution of 1 Å and a signal to noise ratio better than 40. But at a pinch one may accept a resolution of 2 Å and a signal to noise ratio of 15 for the shortest range of the Ap star spectrum.

2019 ◽  
Author(s):  
Alexander V. Rodin ◽  
Dmitry V. Churbanov ◽  
Sergei G. Zenevich ◽  
Artem Yu. Klimchuk ◽  
Vladimir M. Semenov ◽  
...  

Abstract. We propose a new technique of remote wind measurements based on Doppler analysis of a CO2 absorption line in the 1.605 μm overtone band measured in the direct Sun observation geometry. Heterodyne spectroradiometric measurements of the solar radiation passed through the atmosphere provides an unprecedented spectral resolution up to λ/δλ ~ 107–108 with a signal-to-noise ratio more than 100. The shape of the individual rotational line profile provides unambiguous relationship between offset from the line centre and altitude where a respective part of the line profile is formed. Therefore, an inverse problem may be posed in order to retrieve vertical distribution of wind, with retrievals vertical resolution compromised by a spectral resolution and signal-to-noise ratio of the measurements. A close coincidence between measured and synthetic absorption line is reached, with retrieved wind profile between the surface and 50 km being in a good agreement with reanalysis models. This method may pose an alternative to widely employed lidar and radar techniques.


2021 ◽  
Vol 12 ◽  
Author(s):  
Zahra Shams ◽  
Wybe J. M. van der Kemp ◽  
Uzay Emir ◽  
Jan Willem Dankbaar ◽  
Tom J. Snijders ◽  
...  

The onco-metabolite 2-hydroxyglutarate (2HG), a biomarker of IDH-mutant gliomas, can be detected with 1H MR spectroscopy (1H-MRS). Recent studies showed measurements of 2HG at 7T with substantial gain in signal to noise ratio (SNR) and spectral resolution, offering higher specificity and sensitivity for 2HG detection. In this study, we assessed the sensitivity of semi-localized by adiabatic selective refocusing (sLASER) and J-difference MEsher-GArwood-semi-LASER (MEGA-sLASER) for 2HG detection at 7T. We performed spectral editing at long TE using a TE-optimized sLASER sequence (110 ms) and J-difference spectroscopy using MEGA-sLASER (TE = 74ms) in phantoms with different 2HG concentrations to assess the sensitivity of 2HG detection. The robustness of the methods against B0 inhomogeneity was investigated. Moreover, the performance of these two techniques was evaluated in four patients with IDH1-mutated glioma. In contrary to MEGA-sLASER, sLASER was able to detect 2HG concentration as low as 0.5 mM. In case of a composite phantom containing 2HG with overlapping metabolites, MEGA-sLASER provided a clean 2HG signal with higher fitting reliability (lower %CRLB). The results demonstrate that sLASER is more robust against field inhomogeneities and experimental or motion-related artifacts which promotes to adopt sLASER in clinical implementations.


Sensors ◽  
2020 ◽  
Vol 20 (17) ◽  
pp. 4725 ◽  
Author(s):  
Jesper B. Christensen ◽  
Lasse Høgstedt ◽  
Søren M. M. Friis ◽  
Jui-Yu Lai ◽  
Ming-Hsien Chou ◽  
...  

Quartz-enhanced photoacoustic sensing is a promising method for low-concentration trace-gas monitoring due to the resonant signal enhancement provided by a high-Q quartz tuning fork. However, quartz-enhanced photoacoustic spectroscopy (QEPAS) is associated with a relatively slow acoustic decay, which results in a reduced spectral resolution and signal-to-noise ratio as the wavelength tuning rate is increased. In this work, we investigate the influence of wavelength scan rate on the spectral resolution and signal-to-noise ratio of QEPAS sensors. We demonstrate the acquisition of photoacoustic spectra from 3.1 μm to 3.6 μm using a tunable mid-infrared optical parametric oscillator. The spectra are attained using wavelength scan rates differing by more than two orders of magnitude (from 0.3 nm s−1 to 96 nm s−1). With this variation in scan rate, the spectral resolution is found to change from 2.5 cm−1 to 9 cm−1. The investigated gas samples are methane (in nitrogen) and a gas mixture consisting of methane, water, and ethanol. For the gas mixture, the reduced spectral resolution at fast scan rates significantly complicates the quantification of constituent gas concentrations.


2022 ◽  
Vol 12 (2) ◽  
pp. 826
Author(s):  
Jing Yuan ◽  
Bo Yu ◽  
Changxiang Yan ◽  
Junqiang Zhang ◽  
Ning Ding ◽  
...  

It is found that the remote sensing parameters such as spectral range, spectral resolution and signal-to-noise ratio directly affect the estimation accuracy of soil moisture content. However, the lack of research on the relationship between the parameters and estimation accuracy restricts the prolongation of application. Therefore, this study took the demand for this application as the foothold for developing spectrometry. Firstly, a method based on sensitivity analysis of soil radiative transfer model-successive projection algorithm (SA-SPA) was proposed to select sensitive wavelengths. Then, the spectral resampling method was used to select the best spectral resolution in the corresponding sensitive wavelengths. Finally, the noise-free spectral data simulated by the soil radiative transfer model was added with Gaussian random noise to change the signal-to-noise ratio, so as to explore the influence of signal-to-noise ratio on the estimation accuracy. The research results show that the estimation accuracy obtained through the SA-SPA (RMSEP < 12.1 g kg−1) is generally superior to that from full-spectrum data (RMSEP < 14 g kg−1). At selected sensitive wavelengths, the best spectral resolution is 34 nm, and the applicable signal-to-noise ratio ranges from 150 to 350. This study provides technical support for the efficient estimation of soil moisture content and the development of spectrometry, which comprehensively considers the common influence of spectral range, spectral resolution and signal-to-noise ratio on the estimation accuracy of soil moisture content.


Crystals ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1111
Author(s):  
Haowen Liu ◽  
Honglin Li ◽  
Shuren Zhou ◽  
Hong Zhang ◽  
Shiqiang Fan ◽  
...  

Recently, as an emerging material, ultrawide bandgap Ga2O3 has been investigated extensively in solar-blind deep-ultraviolet (DUV) photodetectors (PDs). High sensitivity and signal-to-noise ratio of PDs are essential for the detection of solar-blind DUV signals; however, such factors are often not mutually compatible. In the present study, an amorphous/monoclinic homogeneous mixed-phase structure was demonstrated to be significantly beneficial in enhancing the comprehensive performance of Ga2O3 solar-blind DUV PDs, especially with respect to sensitivity and the signal-to-noise ratio. Further experimental and theoretical findings provide insights on the transport mechanism of enhanced performance in the mixed-phase Ga2O3 solar-blind DUV PD. For effectively separating the photogenerated carriers, a type-II band alignment between amorphous and crystalline Ga2O3 can be exploited. Furthermore, the change of the barrier height of the mixed-phase interface also has a significant impact on the transport properties of the mixed-phase Ga2O3 PD. Additionally, the potential applications of mixed-phase Ga2O3 PD in high-voltage corona discharge were explored, and clear and stable corona discharge signals were obtained. The results of the present study may promote understanding of DUV photoelectronic devices with various mixed-phase Ga2O3 materials and provide an efficient approach for promoting comprehensive performance in future solar-blind detection applications.


2020 ◽  
Vol 13 (5) ◽  
pp. 2299-2308 ◽  
Author(s):  
Alexander V. Rodin ◽  
Dmitry V. Churbanov ◽  
Sergei G. Zenevich ◽  
Artem Y. Klimchuk ◽  
Vladimir M. Semenov ◽  
...  

Abstract. We propose a new technique of remote wind measurements based on Doppler analysis of a CO2 absorption line in the 1.605 µm overtone band measured in the direct Sun observation geometry. Heterodyne spectroradiometric measurements of the solar radiation passing through the atmosphere provide an unprecedented spectral resolution up to λ/δλ∼6×107, with a signal-to-noise ratio of more than 100. The shape of the individual rotational line profile provides an unambiguous relationship between the offset from the line center and the altitude at which the respective part of the line profile is formed. Therefore, an inverse problem may be posed in order to retrieve the vertical distribution of wind because with retrievals the vertical resolution is compromised by a spectral resolution and the signal-to-noise ratio of the measurements. A close coincidence between the measured and synthetic absorption line is reached, with retrieved wind profiles between the surface and 50 km being in good agreement with reanalysis models. This method may pose an alternative to widely employed lidar and radar techniques.


Sign in / Sign up

Export Citation Format

Share Document