scholarly journals VIRTUAL PALEONTOLOGY—AN OVERVIEW

2016 ◽  
Vol 22 ◽  
pp. 1-20 ◽  
Author(s):  
Mark Sutton ◽  
Imran Rahman ◽  
Russell Garwood

AbstractVirtual paleontology is the study of fossils through three-dimensional digital visualizations; it represents a powerful and well-established set of tools for the analysis and dissemination of fossil data. Techniques are divisible into tomographic (i.e., slice-based) and surface-based types. Tomography has a long predigital history, but the recent explosion of virtual paleontology has resulted primarily from developments in X-ray computed tomography (CT), and of surface-based technologies (e.g., laser scanning). Destructive tomographic methods include forms of physical-optical tomography (e.g., serial grinding); these are powerful but problematic techniques. Focused Ion Beam (FIB) tomography is a modern alternative for microfossils; it is also destructive but is capable of extremely high resolutions. Nondestructive tomographic methods include the many forms of CT, which are the most widely used data-capture techniques at present, but are not universally applicable. Where CT is inappropriate, other nondestructive technologies (e.g., neutron tomography, magnetic resonance imaging, optical tomography) can prove suitable. Surface-based methods provide portable and convenient data capture for surface topography and texture, and might be appropriate when internal morphology is not of interest; technologies include laser scanning, photogrammetry, and mechanical digitization. Reconstruction methods that produce visualizations from raw data are many and various; selection of an appropriate workflow will depend on many factors, but is an important consideration that should be addressed prior to any study. The vast majority of three-dimensional fossils can now be studied using some form of virtual paleontology, and barriers to broader adaptation are being eroded. Technical issues regarding data sharing remain problematic. Technological developments continue; those promising tomographic recovery of compositional data are of particular relevance to paleontology.

Author(s):  
T. Yaguchi ◽  
M. Konno ◽  
T. Kamino ◽  
M. Ogasawara ◽  
K. Kaji ◽  
...  

Abstract A technique for preparation of a pillar shaped sample and its multi-directional observation of the sample using a focused ion beam (FIB) / scanning transmission electron microscopy (STEM) system has been developed. The system employs an FIB/STEM compatible sample rotation holder with a specially designed rotation mechanism, which allows the sample to be rotated 360 degrees [1-3]. This technique was used for the three dimensional (3D) elemental mapping of a contact plug of a Si device in 90 nm technology. A specimen containing a contact plug was shaped to a pillar sample with a cross section of 200 nm x 200 nm and a 5 um length. Elemental analysis was performed with a 200 kV HD-2300 STEM equipped with the EDAX genesis Energy dispersive X-ray spectroscopy (EDX) system. Spectrum imaging combined with multivariate statistical analysis (MSA) [4, 5] was used to enhance the weak X-ray signals of the doped area, which contain a low concentration of As-K. The distributions of elements, especially the dopant As, were successfully enhanced by MSA. The elemental maps were .. reconstructed from the maps.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jiyu Sun ◽  
Wei Wu ◽  
Limei Tian ◽  
Wei Li ◽  
Fang Zhang ◽  
...  

AbstractNot only does the Dynastes tityus beetle display a reversible color change controlled by differences in humidity, but also, the elytron scale can change color from yellow-green to deep-brown in specified shapes. The results obtained by focused ion beam-scanning electron microscopy (FIB-SEM), show that the epicuticle (EPI) is a permeable layer, and the exocuticle (EXO) is a three-dimensional photonic crystal. To investigate the mechanism of the reversible color change, experiments were conducted to determine the water contact angle, surface chemical composition, and optical reflectance, and the reflective spectrum was simulated. The water on the surface began to permeate into the elytron via the surface elemental composition and channels in the EPI. A structural unit (SU) in the EXO allows local color changes in varied shapes. The reflectance of both yellow-green and deep-brown elytra increases as the incidence angle increases from 0° to 60°. The microstructure and changes in the refractive index are the main factors that influence the process of reversible color change. According to the simulation, the lower reflectance causing the color change to deep-brown results from water infiltration, which increases light absorption. Meanwhile, the waxy layer has no effect on the reflection of light. This study lays the foundation to manufacture engineered photonic materials that undergo controllable changes in iridescent color.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Alexey A. Polilov ◽  
Anastasia A. Makarova ◽  
Song Pang ◽  
C. Shan Xu ◽  
Harald Hess

AbstractModern morphological and structural studies are coming to a new level by incorporating the latest methods of three-dimensional electron microscopy (3D-EM). One of the key problems for the wide usage of these methods is posed by difficulties with sample preparation, since the methods work poorly with heterogeneous (consisting of tissues different in structure and in chemical composition) samples and require expensive equipment and usually much time. We have developed a simple protocol allows preparing heterogeneous biological samples suitable for 3D-EM in a laboratory that has a standard supply of equipment and reagents for electron microscopy. This protocol, combined with focused ion-beam scanning electron microscopy, makes it possible to study 3D ultrastructure of complex biological samples, e.g., whole insect heads, over their entire volume at the cellular and subcellular levels. The protocol provides new opportunities for many areas of study, including connectomics.


2007 ◽  
Vol 15 (2) ◽  
pp. 26-31 ◽  
Author(s):  
Ben Lich

DualBeam instruments that combine the imaging capability of scanning electron microscopy (SEM) with the cutting and deposition capability of a focused ion beam (FIB) provide biologists with a powerful tool for investigating three-dimensional structure with nanoscale (1 nm-100 nm) resolution. Ever since Van Leeuwenhoek used the first microscope to describe bacteria more than 300 years ago, microscopy has played a central role in scientists' efforts to understand biological systems. Light microscopy is generally limited to a useful resolution of about a micrometer. More recently the use of confocal and electron microscopy has enabled investigations at higher resolution. Used with fluorescent markers, confocal microscopy can detect and localize molecular scale features, but its imaging resolution is still limited. SEM is capable of nanometer resolution, but is limited to the near surface region of the sample.


1999 ◽  
Vol 594 ◽  
Author(s):  
R. Spolenak ◽  
C. A. Volkert ◽  
K. Takahashi ◽  
S. Fiorillo ◽  
J. Miner ◽  
...  

AbstractIt is well known that the mechanical properties of thin films depend critically on film thickness However, the contributions from film thickness and grain size are difficult to separate, because they typically scale with each other. In one study by Venkatraman and Bravman, Al films, which were thinned using anodic oxidation to reduce film thickness without changing grain size, showed a clear increase in yield stress with decreasing film thickness.We have performed a similar study on both electroplated and sputtered Cu films by using chemical-mechanical polishing (CMP) to reduce the film thickness without changing the grain size. Stress-temperature curves were measured for both the electroplated and sputtered Cu films with thicknesses between 0.1 and 1.8 microns using a laser scanning wafer curvature technique. The yield stress at room temperature was found to increase with decreasing film thickness for both sets of samples. The sputtered films, however, showed higher yield stresses in comparison to the electroplated films. Most of these differences can be attributed to the different microstructures of the films, which were determined by focused ion beam (FIB) microscopy and x-ray diffraction.


Author(s):  
W. N. P. Hung ◽  
M. M. Agnihotri ◽  
M. Y. Ali ◽  
S. Yuan

Traditional micromanufacturing has been developed for semiconductor industry. Selected micro electrical mechanical systems (MEMS) have been successfully developed and implemented in industry. Since current MEMS are designed for manufacture using microelectronics processes, they are limited to two-dimensional profiles and semiconductor based materials. Such shape and material constraints would exclude many applications that require biocompatibility, dynamic stress, and high ductility. New technologies are sought to fabricate three dimensional microcomponents using robust materials for demanding applications. To be cost effective, such microdevices must be economically mass producible. Molding is one of the promising replication techniques to mass produce components from polymers and polymer-based composites. This paper presents the development of a micromolding process to produce thermoplastic microcomponents. Mold design required precision fitting and was integrated with a vacuum pump to minimize air trap in mold cavities. Nickel and aluminum mold inserts were used for the study; their cavities were fabricated by combinations of available micromachining processes like laser micromachining, micromilling, micro electrical discharge machining, and focused ion beam sputtering. High and low density polyethylene, polystyrene polymers were used for this study. The effects of polymer molecular structures, molding temperature, time, and pressure on molding results were studied. Simulation of stress in the microcomponents, plastic flow in microchannels, and mold defects was performed and compare with experimental data. The research results showed that a microcomponent can be fabricated to the minimum size of 10 ± 1μm (0.0004 inch) with surface roughness <10 nm Rt. Molding of micro-size geartrains and orthopedic meso-size fasteners was completed to illustrate the capability of this process.


Sign in / Sign up

Export Citation Format

Share Document